Note) l/min (ANR) is for reference conditions of 20C, 1 ATM and 65% relative humidity. Features 3 Model Selection Data A Correction factor for temperature/Series IDU Inlet air temp.
Accessory (Option) D Auto-drain F Dust-protecting filter S Mounting bench 7 15 22 37 7.5 KW 15 KW 22 KW 37 KW Caution on Design Caution 1. Do not to obstruct the aftercooler's vent inlet and outlet, and install the equipment more than 20 cm away from the walls or other equipment. 2. Install the aftercooler in a location that facilitates maintenance and inspection. 3.
Flow rate conversion NO OFF n-2 n-1 High flow rate Basic state: 0C, 101.3kPa Standard state: 20C, 101.3kPa, 65%RH (ANR) Switchable between these states.
19 x 16 25 x 22 19 x 16 Tubing O.D.
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor.) Note 2) Impact resistance: No malfunction occurred when it was tested in the axial direction and at right angles to the main valve and armature in both energized and de-energized states once for each condition.
Membrane Dyer Series IDG Standard specifications/Single style (standard dew point 20C) Model Standard dew point 20C IDG5 IDG10 IDG20 IDG30 IDG50 Fluid Compressed air Macromolecular membrane dryers that act like filters Range of operating conditions Standard performance conditions Inlet air pressure MPa 0.3 to 0.85 0.3 to 1.0 Inlet air temperature C Note 1) 5 to 55 Ambient temperature C 5
21.5 31 17.5 16.1 18 41 62.4 24.3 38.1 66.2 26.2 40 16.5 3.5 16.8 18.7 11 1.2 41 56 17 40 60 6 8 VHK-B1A 44.5 11.5 27 22 16.5 26 9.7 7.2 3 8 22 46 74.8 30.5 44.3 77.3 31.5 45.8 21.5 4 20.8 21.8 14 3.2 51 68 19 64 71 22 10 12 VHK-B2A 49 17 1 30 25 21.5 31 17.5 16.1 22 46 78.2 30.5 47.7 80.2 31.5 48.7 21.5 4 20.8 21.8 14 3.2 72 70 22 70 72 10 12 VHK-B2A 49 17 1 30 25 21.5 31 17.5 16.1 1 2
x n)+78 AL 20 22 18 28 28 52.5 5.3 39 14 3 5 5.5 SMC SMC 0.1 0.3 0.2 0.4 0.5 0.6 SMC MPa 84 56 8 11.5 28 L2 dimension Stations 1 2 3 4 5 6 7 8 9 M DIN rail part no.
CS2 Series CS2 125, 140 JISB4636 Dodecagon 22 Class2, M14 x 1.5 160 JISB4636 Dodecagon 24 Class2, M16 x 1.5 a.
Note) Supply pressure: 0.5MPa, Temperature: 20C. In-line style How to Order 1F 12 K 400 AS JIS Symbol Option Body size K N None Hexagonal lock nut Electroless nickel plated 100 200 205 300 400 M5 1/8 1/4 3/8 1/2 Indicate symbols in alphabetical order if two options or more desired. Applicable tube O.D.
Automatic monitoring Alarm will not be generated until it reaches the time set for the AS.22 "Monitoring start timer" after the operation starts. Alarm monitoring starts when it reaches the set time. Monitoring start timer Alarm will not be generated until it reaches the time set for the AS.22 "Monitoring start timer" after the operation starts.
Insulation resistance Mkm, 20C (68F) 5 or more 16 44 8 SMC Connector manufacturers Fujitsu Ltd. Japan Aviation Electronics Industry, Ltd. J. S. T. Manufacturing Co., Ltd.
AN200 to 900 1 Model 0.5 A B D Dimensions (mm) Model Port size R Weight (g) Recommended flow (m3/min (ANR)) 3 or less 5 or less 8 or less 12 or less 20 or less 30 or less 50 or less 80 or less Effective area (mm2) 35 60 90 160 270 440 590 960 2 0.2 Inlet pressure (MPa) Noise level (dB) (A) 0.1 1 4 AN200-02 17 63 22 19 25 84 25 22 35 92 30 27 165 107 46 36 225 132 50 41 490 200 74 55 580 233
B (+) () 22 SOL. A (+) () 23 Station 12 SOL. B (+) () 24 COM () (+) 25 Special wiring specifications (options) COM () (+) 26 Positive COM spec. Negative COM spec. COM COM 25 26 COM COM 23 24 Note) When using the negative COM specification, use valves for negative COM. 21 22 Mixed single and double wiring are available as options.
When the ambient temperature is 20C 5C and rated voltage is applied. Changing coils from AC to DC and vice versa is impossible, because of different core shapes. VXP21 0, 22 0, 23 0 are possible to exchange coil from AC to DC, but impossible from DC to AC. (Hum sound may generate because of no shading coil for DC.
22 2.6 2.6 2.6 9.3 9.3 4 4 6 Most sensitive position 6 Most sensitive position 507 A
Insulation resistance Mkm, 20C 5 or less 16 44 8 SMC Connector manufacturers example Fujitsu, Ltd. Japan Aviation Electronics Industry, Ltd. J.S.T. Mfg. Co., Ltd.
Bore Size: 12mm, Symmetric Type: L (Symmetric), Stroke: 20mm, Adjuster: C (Both Side Adjusters/Metal Stoppers), Function: Standard, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal
Bore Size: 12mm, Symmetric Type: Symmetric, Stroke: 20mm, Adjuster: Both Side Adjusters/Metal Stoppers, Function: Standard, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: -, Number: -
" 1/4" 5/16" 3/8" 3/8" 1/2" 8.4 9.3 11.4 12 9.3 11.4 13.2 11.4 13.2 15.2 13.2 15.2 17.9 17.9 21.7 12.7 12.7 10.5 10.5 13.5 12.7 13.5 17 18 17 18 21 22 21 22 16.5 13.7 12.7 16.5 17 16.5 17 18 17 18 21 21 22 22.4 25.2 6.2 12.3 27.6 28.6 29.5 29.6 30.5 27.6 33.3 34.1 35.3 43.5 44.9 32.6 33.6 34.5 34.6 35.5 32.6 38.3 39.1 40.3 51 52.4 5.2 6.2 7.1 6.2 7.1 8.1 7.4 8.2 9.5 10.3 11.6 12.3 15.5 15.5