SMC Corporation of America
Elite Part Number Search
Search Results "53-SY5120-L3-C6-F2"

Load mass (kg) m1 m2 m3 Moment (Nm) M3 = F3 x L3 F3 M1 = F1 x L1 F1 M2 = F2 x L2 F2 L1 L2 L3 1. Maximum load mass (1), static moment (2), and dynamic moment (3) (at the time of impact with stopper) must be examined for the selection calculations. To evaluate, use a (average speed) for (1) and (2), and (impact speed = 1.4a) for (3).

Load (kg) m1 m4 m2 m3 Moment (Nm) F3 M3=F3 x L3 L3 F1 M1=F1 x L1 F2 M2=F2 x L2 L1 L2 1. Maximum allowable load (1), static moment (2), and dynamic moment (3) (at the time of impact with stopper) must be examined for the selection calculations. Maximum Allowable Load To evaluate, use a (average speed) for (1) and (2), and (impact speed = 1.4a) for (3).

Load (kg) m1 m4 m2 m3 Moment (Nm) F3 M3=F3 x L3 L3 F1 M1=F1 x L1 F2 M2=F2 x L2 L1 L2 1. Maximum allowable load (1), static moment (2), and dynamic moment (3) (at the time of impact with stopper) must be examined for the selection calculations. Maximum Allowable Load To evaluate, use a (average speed) for (1) and (2), and (impact speed = 1.4a) for (3).

Load weight (kg) m1 m2 m3 Moment (Nm) M3 = F3 x L3 F3 M1 = F1 x L1 F1 M2 = F2 x L2 F2 L1 L2 L3 1. Maximum load weight (1), static moment (2), and dynamic moment (3) (at the time of impact with stopper) must be examined for the selection calculations. To evaluate, use a (average speed) for (1) and (2), and (impact speed = 1.4a) for (3).

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com m4 m2 m3 Moment (Nm) F3 M3=F3 x L3 L3 F1 M1=F1 x L1 F2 M2=F2 x L2 L1 L2 1.

size C4 (4 Onetouch fitting) C4 (4 One-touch fitting) A, B port C6 (6 One-touch fitting) M5 x 0.8 Flow Rate Characteristics Flow rate characteristics Port size 1 4/2 (P A/B) 4/2 5/3 (A/B R) Manifold C [dm3/(sbar)] b Cv C [dm3/(sbar)] b Cv 1(P), 5/3(R) port 2(B), 4(A) port M5 x 0.8 C4 C6 M5 x 0.8 M5 x 0.8 1/8 C6 C4 1/8 1/8 1/8 1/8 1/8 1/4 1/4 1/8 0.46 0.62 0.79 0.55 0.59 0.74 0.71 0.55

Formula L1 = 11n + 20 n: Station (Maximum 24) 2n-C3, C4, C6, M5 C3: One-touch fitting for 3.2 C4: One-touch fitting for 4 C6: One-touch fitting for 6 M5: M5 thread 1 2 3 4 5 6 7 8 9 10 11 12 42 62.5 73 n L L1 L2 L3 152 175 185.5 141 162.5 173 130 150 160.5 119 137.5 148 108 125 135.5 64 87.5 98 97 125 135.5 53 75 85.5 86 112.5 123 31 50 60.5 75 100 110.5 n L 13 14 15 16 17 18 19 20 21 22

C8 1/8 C6 C8 1/8 1/8 C6 C8 SS5YJ7-20 Body ported SYJ72 for internal pilot SS5YJ7-21 SS5YJ7-40 SS5YJ7-41 SS5YJ7-42-C6 SS5YJ7-42-C8 Base mounted SYJ74 for internal pilot Note) Value at manifold base mounted, 2 position single operating How to Order Manifold (Example) Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold base model

Bore MM *NA P S W X Y LC LD LH LS LT LX LZ Without gaiter (mm) H ZZ 20 M8x1.25 24 1/8 77 10 15 7 4 5.5 20 53 3 32 44 35 147 25 M10x1.25 29 1/8 77 10 15 7 4 5.5 22 53 3 36 49 40 157 32 M10x1.25 36 1/8 79 10 16 8 4 6.6 25 53 3 44 58 40 159 40 M14x1.5 44 1/8 87 10 16.5 9 4 6.6 30 60 3 54 71 50 187 50 M18x1.5 55 1/4 102 17.5 22 11 5 9 40 67 4.5 66 86 58 218 63 M18x1.5 69 1/4 102 17.5 22 13 5

2 to 20 stations Valve Rc Rc Rc 1 4 1(P), 3/5(R) port 4(A), 2(B) port 1 8 , C6, C8 1 8 Port size Flow Characteristics Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R) Port size Manifold C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv 1(P), 5/3(R) port 2(B), 4(A) port VV5Z5-20-01 VV5Z5-20-C6 VV5Z5-20-C8 VV5Z5-21-01 VV5Z5-21-C6 VV5Z5-21-C8 1/8 C6 C8 1/8 C6 C8 0.55 0.49 0.51 0.54 0.50 0.50

connector (M) VZ3220-M-M5 300 (Lead wire length) 300 (Lead wire length) : With light/surge voltage suppressor DIN terminal (D) VZ3220-D-M5 C4 C6 Built-in One-touch fittings VZ3220-MAX. 10 C4: MAX. 7 C6: MAX. 7.5 Applicable cable O.D. 3.5 to 7 2-One-touch fitting (A, B port) Applicable tubing model C4: T0425 C6: T0604 3-3-22 5 Port Solenoid Valve Body Ported Series VZ3000 3 Position Closed

175 152 17 7 198 187.5 168 15 8 210.5 200 184 13.5 9 223 212.5 200 11.5 10 248 237.5 216 16 Stations L1 L2 L3 L4 : With light/surge voltage suppressor 3-3-51 Series VZ3000 Type 45F DIN Rail Manifold (Non Plug-in): Side Ported VV5Z3-45FDStation C4C C6C C4 (Pitch) (Pitch) 2n-One-touch fitting 2n-One-touch fitting (A, B port) Applicable tubing model C6: T0604 (A, B port) Applicable tubing model

Applicable shaft type: W (mm) Y L2 L2 max Size (mm) E3 = E1 = Y = 10 3 to 8 5 ( 8 Y) to (Y 1) Y-1 L1 L3 max X Size L2 = L4 = 10 9 (14 X) to (X 1) 15 3 to 9 6 ( 9 Y) to (Y 1.5) Y-1.5 3 to 14 X 1 L1 = 15 10 (18 X) to (X 1.5) 20 3 to 10 7 (10 Y) to (Y 1.5) Y-1.5 3 to 18 X 1.5 L3 = X = 20 10 (20 Xs) to (X 1.5) 30 5 to 13 8 (13 Y) to (Y 2) Y-2 3 to 20 X 1.5 30 12 (22 X) to (X 2) 40 7 to 15 9 (

.\ L3 2.83 (72\ 3.46 (88) 4.09 (104) 4.72 (120\ 5.35 (136) 5.98 (152) 6.61 (168) 7.24 (18/.\ 7.87 (2001 Millimtef in parentheses, 53 C Single-Stage Nozzle (o1.5) . Produces high suction flow with quick response time. . Interchangeable with all other nozzleldiffuser ass'ys.

L3 2.83 (72\ 3.46 (88) 4.09 (104) 4.72 (120\ 5.35 (136) 5.98 (152) 6.61 (168) 7.24 (18/.\ 7.87 (2001 Millimtef in parentheses 53 C Single-Stage Nozzle (o1.5) . Produces high suction flow with quick response time. . Interchangeable with all other nozzleldiffuser ass'ys.

VN VQ30 LVC LVA JIS Symbol LVH (A) 2 Characteristic Specifications LVD VQ20 VQ30 Series LVQ 1 (P) C8 C6 C10 C12 N.C.

Measurement mode] 25 Change of Set Value [3 step setting mode] 26 Default setting 26 Change of Set Flow and Hysteresis [Simple setting mode] 31 Simple setting mode 29 Change the Function Settings [Function selection mode] 31 Function selection mode 31 Default setting 32 F0 Reference condition/Units selection function/Switch output function/ Output object/Display colour 33 F1 Setting of OUT1 37 F2

for 8 One-touch fitting for 10 One-touch fitting for 12 VQ30 VQ20 Symbol 2 3 Effective orifice 3.4mm 4.8mm Series VQ20 VQ30 Symbol C6 C8 C10 C12 Switching N.C.

We=1.4xVaxWx10 L2 W2 M3=F3x L3 M= WexL =5xVaxWxL 3 F3 L3 an= F W4 Fmax W3 F : Calculated load Fmax : Maximum allowable load under the condition of allowable speed (value obtained from graph) Ek= W V2 2g Allowable moment and maximum load Model Allowable moment N.m Maximum load N M1 M2 M3 W1 W2 W3 W4 ML2B25 10.0 1.2 3.0 200.0

Separate cable IZT40-CF Shield wire Semi-stripped terminal Cable length L3 Cable specification Product No. L3(mm) Number of wire /size 12 cables/AWG20(4pcs. ), AWG(8pcs.) Nominal cross section 0.54mm2(4pcs.), 0.09mm2(8 pcs.) 0.96mm (4pcs. ), 0.38mm (8pcs. ) IZT40-CP3 2950 Conductor O.D.