Load (kg) m1 m4 m2 m3 Moment (Nm) F3 M3=F3 x L3 L3 F1 M1=F1 x L1 F2 M2=F2 x L2 L1 L2 1. Maximum allowable load (1), static moment (2), and dynamic moment (3) (at the time of impact with stopper) must be examined for the selection calculations. Maximum allowable load To evaluate, use a (average speed) for (1) and (2), and (impact speed = 1.4a) for (3).

F1 = X A1 X P . (1) F2 = X A2 X P . (2) 4 A1 = D2 . (3) 4 A2 = (D2 d2) . (4) F1 = Cylinder force generated on the extending side (N) F2 = Cylinder force generated on the retracting side (N) = Load rate A1 = Piston area on the extending side (mm2) A2 = Piston area on the retracting side (mm2) D = Tube bore size (mm) d = Piston rod diameter (mm) P = Operating pressure (MPa) While not

D1.6 x P First tentative bore size determination F1 D1.6 x P WB Inclined operation W+WBWV PPV W + WB>WV P>PV Allowable driving force table (Fn) (n = 1, 2, 3) Determination of allowable load weight & pressure F1 = x (W + WB) x 9.8 Horizontal F2 = (W + WB) x 9.8 x (cos + sin) Inclined F3 = (W + WB) x 9.8 x ( + 1) Vertical (Refer to page 4 for connection fitting weight.)

+ WB > WV P > PV Determination of allowable load weight & pressure F1 = x (W + WB) x 9.8 Horizontal Inclined Vertical F2 = (W + WB) x 9.8 x (cos + sin) (See page 63 for vertical operation.)

Actuation: 4 (3-Position Exhaust Center), Electrical Entry: TT (Terminal Type), Lead Wire Length: 3 (300mm), Manual Override: Non-locking Push Type, A,B Port: 01 (1/8), Thread Type: T (NPTF), Bracket: F2 (w/Side Bracket)

Actuation: 3 (3-Position Closed Center), Electrical Entry: TT (Terminal Type), Lead Wire Length: 3 (300mm), Manual Override: Non-locking Push Type, A,B Port: N7 (ø1/4" One-touch Fitting, Inch), Thread Type: Rc, Bracket: F2 (w/Side Bracket)

Actuation: 4 (3-Position Exhaust Center), Electrical Entry: TT (Terminal Type), Lead Wire Length: 3 (300mm), Manual Override: Non-locking Push Type, A,B Port: N9 (ø5/16" One-touch Fitting, Inch), Thread Type: Rc, Bracket: F2 (w/Side Bracket)

Actuation: 3 (3-Position Closed Center), Electrical Entry: TT (Terminal Type), Lead Wire Length: 3 (300mm), Manual Override: Non-locking Push Type, A,B Port Size: 02 (1/4), Thread Type: N (NPT), Bracket: F2 (w/Side Bracket)

Actuation: 4 (3-Position Exhaust Center), Electrical Entry: TT (Terminal Type), Lead Wire Length: 3 (300mm), Manual Override: Non-locking Push Type, A,B Port Size: 02 (1/4), Thread Type: N (NPT), Bracket: F2 (w/Side Bracket)

Actuation: 5 (3-Position Pressure Center), Electrical Entry: TT (Terminal Type), Lead Wire Length: 3 (300mm), Manual Override: Non-locking Push Type, A,B Port Size: 02 (1/4), Thread Type: N (NPT), Bracket: F2 (w/Side Bracket)

Actuation: 2 (2-Position Double), Electrical Entry: TT (Terminal Type), Lead Wire Length: 3 (300mm), Manual Override: Non-locking Push Type, A,B Port Size: 02 (1/4), Thread Type: N (NPT), Bracket: F2 (w/Side Bracket)

Actuation: 2 (2-Position Double), Electrical Entry: TT (Terminal Type), Lead Wire Length: 3 (300mm), Manual Override: Non-locking Push Type, A,B Port Size: 02 (1/4), Thread Type: Rc, Bracket: F2 (w/Side Bracket)

Actuation: 1 (2-Position Single), Electrical Entry: TT (Terminal Type), Lead Wire Length: 3 (300mm), Manual Override: Non-locking Push Type, A,B Port Size: 02 (1/4), Thread Type: N (NPT), Bracket: F2 (w/Side Bracket)

Actuation: 3-Position Exhaust Center, Electrical Entry: Terminal Type, Lead Wire Length: 300mm, Manual Override: Non-locking Push Type, A,B Port: 1/8, Thread Type: NPTF, Bracket: w/Side Bracket

Actuation: 3-Position Closed Center, Electrical Entry: Terminal Type, Lead Wire Length: 300mm, Manual Override: Non-locking Push Type, A,B Port: ø1/4" One-touch Fitting, Inch, Thread Type: Rc, Bracket: w/Side Bracket

Actuation: 3-Position Exhaust Center, Electrical Entry: Terminal Type, Lead Wire Length: 300mm, Manual Override: Non-locking Push Type, A,B Port: ø5/16" One-touch Fitting, Inch, Thread Type: Rc, Bracket: w/Side Bracket

Actuation: 3-Position Closed Center, Electrical Entry: Terminal Type, Lead Wire Length: 300mm, Manual Override: Non-locking Push Type, A,B Port Size: 1/4, Thread Type: NPT, Bracket: w/Side Bracket

Actuation: 3-Position Exhaust Center, Electrical Entry: Terminal Type, Lead Wire Length: 300mm, Manual Override: Non-locking Push Type, A,B Port Size: 1/4, Thread Type: NPT, Bracket: w/Side Bracket

Actuation: 3-Position Pressure Center, Electrical Entry: Terminal Type, Lead Wire Length: 300mm, Manual Override: Non-locking Push Type, A,B Port Size: 1/4, Thread Type: NPT, Bracket: w/Side Bracket

Actuation: 2-Position Double, Electrical Entry: Terminal Type, Lead Wire Length: 300mm, Manual Override: Non-locking Push Type, A,B Port Size: 1/4, Thread Type: NPT, Bracket: w/Side Bracket