Body Size: 30, Thread: NPT, Port Size: 3/8, Option: N.C. Float Type Auto Drain, Attachment: Standard, Semi-Standard 1: 0.02 to 0.2MPa Setting, Semi-Standard 2: Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F
Body Size: 30, Thread: NPT, Port Size: 3/8, Option: D + G, Attachment: Standard, Semi-Standard 1: 0.02 to 0.2MPa Setting, Semi-Standard 2: Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F
Body Size: 30, Thread: NPT, Port Size: 3/8, Option: C + G, Attachment: Standard, Semi-Standard 1: 0.02 to 0.2MPa Setting, Semi-Standard 2: Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: C (N.C. Float Type Auto Drain), Attachment: Standard, Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: CG (C + G), Attachment: Standard, Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: DG (D + G), Attachment: Standard, Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: D (N.O. Float Type Auto Drain), Attachment: Standard, Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
It is set to these values when delivered. 2.1 Communication Procedure This product receives a request message from the master computer and sends back a corresponding response message. It does not send a message firstly.
It is set to these values when delivered. 2.1 Communication Procedure This product receives a request message from the master computer and sends back a corresponding response message. It does not send a message firstly.
Connect one of the wires of the valve to the output terminal block (from SV1), and connect the other wire to the common terminal block (COM). (There is no polarity.) The outputs are output sequentially from SV1 terminals.
The wires used should have a conductor effective area of 0.5 to 1.25 mm2.
The VXFC□A/D operation manual can be found <a href="/manual/en-jp/?
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: G (Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: V (3-Port Valve for Residual Pressure Release; Mounting: AF+AR+V), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: G (Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: T (T-Interface), Semi-Standard 1: J (Drain Guide 1/8: Size 20; Drain Guide 1/4: Sizes 25, 30, 40), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: G (Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: V1 (3-Port Valve for Residual Pressure Release; Mounting: V+AF+AR), Semi-Standard 1: Standard, Semi-Standard 2: RZ (R + Z)
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: G (Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: V (3-Port Valve for Residual Pressure Release; Mounting: AF+AR+V), Semi-Standard 1: 6J (6 + J), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi,
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: G (Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: SV (S + V), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: NZ (N + Z)
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: G (Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: SV (S + V), Semi-Standard 1: Standard, Semi-Standard 2: WZ (W + Z)
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: G (Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: T (T-Interface), Semi-Standard 1: 16J (1 + 6 + J), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: G (Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: T (T-Interface), Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: RWZ (R + W + Z)
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: G (Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: T (T-Interface), Semi-Standard 1: Standard, Semi-Standard 2: NRZ (N + R + Z)
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: G (Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: T (T-Interface), Semi-Standard 1: Standard, Semi-Standard 2: RZ (R + Z)