SMC Corporation of America
Elite Part Number Search
Search Results "AD402-04D-2-A"

The AD402/600 series auto drain valve automatically discharges drainage. It is highly resistant to dust and corrosion. This series operates in a reliable manner, without requiring human operators.

The AD402/600 series auto drain valve automatically discharges drainage. It is highly resistant to dust and corrosion. This series operates in a reliable manner, without requiring human operators.

The AD402/600 series auto drain valve automatically discharges drainage. It is highly resistant to dust and corrosion. This series operates in a reliable manner, without requiring human operators.

The AD402/600 series auto drain valve automatically discharges drainage. It is highly resistant to dust and corrosion. This series operates in a reliable manner, without requiring human operators.

The AD402/600 series auto drain valve automatically discharges drainage. It is highly resistant to dust and corrosion. This series operates in a reliable manner, without requiring human operators.

The AD402/600 series auto drain valve automatically discharges drainage. It is highly resistant to dust and corrosion. This series operates in a reliable manner, without requiring human operators.

1/2-13 1 1/2 1 3/8 2.34 1 4 1/4 2.72 2 7/16 5/8 2 5/8 5 53/64 3/4-16 7/8 1/2 2 1/4 400 (4) 1 1/8 4.7 1 1/2 1 1/2 1/2 3/8-24 4 1/2 0 1.57 1.18 1/2-13 2 1/16 1 3/8 2.34 1 4 1/4 2.72 2 7/16 5/8 2 5/8 5 53/6 3/4-16 7/8 1/2 MORE DIMENSIONS S E E N E X T P A G E D I M E N S I O N S D E TA C H A B L E R E A R C L E V I S T Y P E NC A1D G BORE (INCH) KK A AA B C D DD E EA EE F L LR M XD MM CB J

D-M9mAV D-A3m D-A44 D-G39 D-K39 D-A9m D-A9mV D-A5m D-A6m D-A59W D-F5m D-J59 D-F59F D-F5NT REA D-P3DWA D-P4DW REB REC A B A B A B A B A B A B A B A B A B A B Bore size 32 10 8 6 4 0 0 4 2 6.5 4.5 11.5 9.5 0 0 3.5 1.5 5.5 3.5 3 1 Smooth Smooth 40 9 9 5 5 0 0 3 3 5.5 5.5 10.5 10.5 0 0 2.5 2.5 4.5 4.5 2 2 50 10 9 6 5 0 0 4 3 6.5 5.5 11.5 10.5 0 0 3.5 2.5 5.5 4.5 3 2 Low Speed 63 10 9 6 5 0 0

A B A B A B B A B A B A B B A B A B A 10 16 2 2 6 6 2.5 2.5 1.5 1.5 0.5 0.5 4.5 4.5 3 3 3.5 3.5 8.5 8.5 0.5 0.5 2.5 2.5 6.5 6.5 3 3 2 2 1 1 5 5 3.5 3.5 4 4 9 9 1 1 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.

A C B Stroke A operation 1) Initial state (0 stroke position) Stroke B Stroke A A C B Stroke A 2) Operation When the air pressure is supplied from the A port, the rod operates the stroke A. A C B Stroke B operation 1) Initial state (0 stroke position) Stroke B Stroke A C 2) Operation When the air pressure is supplied from the C port, the rod operates the stroke B.

D-J59 D-F59F D-F5lW D-J59W D-F5BA D-M9l D-M9lV D-M9lW D-M9lWV D-M9lA D-M9lAV D-B5l D-B64 D-A9l D-A9lV D-A59W D-F5NT D-P3DWA D-P4DW Bore size A B A B A B A B A B A B A B A B A B A B A B 40 10 8 6 4 4 1 5.5 3.5 3.5 0.5 0.5 0 1 0 7 4 2.5 0 4.5 1.5 12 9 50 10 8 6 4 3.5 1.5 5.5 3.5 3 1 0 0 0.5 0 6.5 4.5 2 0 4 2 11.5 9.5 63 12.5 11.5 8.5 7.5 6 5 8 7 5.5 4.5 2.5 1.5 3 2 9 8 4.5 3.5 6.5 5.5 14 13

B A B A B A B A B A B A B A B A B 40 50 63 80 100 6 4 3.5 1.5 0 0.5 6.5 2 4 11.5 10 0 0 4.5 0 2 9.5 8 ML2B 3.5 1.5 0 0.5 6.5 2 4 11.5 10 0 0 4.5 0 2 9.5 8 8.5 7.5 6 5 2.5 3 9 4.5 6.5 14 12.5 1.5 2 8 3.5 5.5 13 11.5 12 10 9.5 7.5 6 6.5 4.5 8 10 17.5 16 4 4.5 12.5 6 8 15.5 14 13.5 12.5 11 10 7.5 8 14 9.5 11.5 19 17.5 6.5 7 13 8.5 10.5 18 16.5 D-A9 and D-A9V cannot be mounted on 50.

A Sensor connector socket Accumulated flow OFF 2 sec. or longer Accumulated output mode Key-lock function CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.

When setting, allow 7 digits or more between Set point 1 and Set point 2 (Set point 3 and Set point 4). 2: When Set point 1 = Set point 2 (Set point 3 = Set point 4), chattering may occur. Set value is calculated and set. Set value 4 Set value or 3 or 3 Measurement mode Do not use the product in a place where static electricity is a problem.

Piping Direction: Vertical Piping, Thread: Rc, Port Size: 3/8, Auto Drain Type: N.C. Normally Closed, Bowl: Metal Bowl, Valve: None, Pressure Unit: Name Plate and Caution Plate for Bowl in SI Units

Piping Direction: Vertical Piping, Thread: Rc, Port Size: 3/8, Auto Drain Type: N.O. Normally Open, Bowl: Metal Bowl, Valve: None, Pressure Unit: Name Plate and Caution Plate for Bowl in SI Units

Piping Direction: Vertical Piping, Thread: Rc, Port Size: 1/2, Auto Drain Type: N.C. Normally Closed, Bowl: Metal Bowl, Valve: None, Pressure Unit: Name Plate and Caution Plate for Bowl in SI Units

Piping Direction: Vertical Piping, Thread: Rc, Port Size: 1/4, Auto Drain Type: N.C. Normally Closed, Bowl: Metal Bowl, Valve: None, Pressure Unit: Name Plate and Caution Plate for Bowl in SI Units

Piping Direction: Vertical Piping, Thread: Rc, Port Size: 1/4, Auto Drain Type: N.O. Normally Open, Bowl: Metal Bowl, Valve: None, Pressure Unit: Name Plate and Caution Plate for Bowl in SI Units