KPT08-01 KPT08-02 KPT10-02 KPT10-03 KPT12-03 KPT12-04 4 4.1 10.4 4.1 20.7 18 10 D1 6 11 12.8 11 22.8 19.5 D2 M A L1 L2 A L2 D1 14 8 12 26.3 15.2 18.2 26.3 21.5 H 10 Connection threads 40.8 18.5 29 29.4 24 17 17 12 57.2 20.9 45.2 31.4 25 22 Reference dimension for R threads after installation Note 1) D1 indicates the maximum diameter.

KPT08-01 KPT08-02 KPT10-02 KPT10-03 KPT12-03 KPT12-04 4 4.1 10.4 4.1 20.7 18 10 D1 6 11 12.8 11 22.8 19.5 D2 M A L1 L2 A L2 D1 14 8 12 26.3 15.2 18.2 26.3 21.5 H 10 Connection threads 40.8 18.5 29 29.4 24 17 17 12 57.2 20.9 45.2 31.4 25 22 Reference dimension for R threads after installation Note 1) D1 indicates the maximum diameter.

ISG 1 03 1 0 0 W Mounting/Piping Caution Multipurpose pressure switch 1. Mounting is possible in either horizontal or vertical orientations. Contacts/Bulb gland Pressure Source Nil W Nil B C 1a1b (Standard) 2ab Contact Warning Enclosure Type A 20a (Standard) Type A 20b Type A 20c Bulb gland 1.

(L1L2L3L11L21) (1.2) (b) (UVW)(UV W) U U V V M W W (UVW) M U V W U V W PE M P1-P2(11kWP1-P) P1 P2 (C) 200V CNP2P-D PC (13.2) 5 3 5 (2) (a) DO CN6ON/OFF (b) CN6 DC24V (c) CN6 SD DOCOM CN6 DOCOM SD 5.1.3 (1) (a) (b) (12.4) (c) (2) 5 4 5 5.2 5.2.1 (1) ON(RYn0) (RYn1)(RYn2)OFF b01(1 ) (A25) ON 3000r/min (2) (RYn1)(RYn2)OFF ON(RYn0) 5 5 5 5.2.2 , 4.11 (a) ON(

42.5 28.3 64.7 17 48 (48) AS331F-03-06(S)A 6 11.2 12.9 16.6 20.2 36 21.4 57.8 AK 1/4 19 50 48.4 44.5 42.9 VCHC 13.3 34 (35) AS331F-03-08(S)A 8 13.2 37.1 23.5 52.2 14.2 35 (36) AS331F-03-10(S)A 10 15.9 17.4 23 41.2 26.1 54.8 15.6 38 (39) AS331F-03-12(S)A 12 18.5 42.5 28.3 57 17 40 (41) AS431F-04-10(S)A 10 1/2 24 (23.8) 15.9 17.4 18.8 25.6 46.4 (46.3) 26.1 61.2 50.8 49.2 43.7 42.1 15.6 61

A type mounting bracket part No.YA-03 Joint YU-03 Joint Part No. Applicable mounting bracket Bore size (mm) Weight (g) Joint part No. B bracket A bracket YB-03 YU-03 YA-03 32, 40 25 YB-05 YU-05 YA-05 50, 63 40 Bore size (mm) YB-08 YU-08 YA-08 80 90 Part No.

manifold block, it is possible to prepare for removing a valve for maintenance reasons or planning to mount a spare valve, etc. 10 Size 18 mm (A) 4 (B) 2 112.4 42 19 26 1 (P) 5 (R1) 3 (R2) Circuit diagram 14 Size 26 mm 112 Individual SUP spacer 49 12.5 (F) (T) (F) (T) VV802-P-01 (Size 18 mm) 18 9 1/8" VV801-P-03 (Size 26 mm) By mounting individual SUP spacers on a manifold block, it is possible

Construction AW20K to 40K A-A i A w t SMC K P q C U O S L H o t OUT (Outlet pressure) IN (Inlet pressure) A Parts list y Material AW20K AW30K AW40K AW40K-06 Description No. Note e Zinc die-cast Aluminum die-cast Platinum silver 1 2 Body r Bonnet Black Polyacetal u Parts no. AW20K Description Material No.

Side 1/4 1/4 1,3,5 (P,EA,EB) Port 1/8 C6 (One-touch fitting for 6) C8 (One-touch fitting for 8) 1/4 Port size 1/4 C6 (One-touch fitting for 6) 4,2 (A,B) Port C10 (One-touch fitting for 10) C8 (One-touch fitting for 8) Manifold base weight W (g) n: Station W = 61n + 101 W = 79n + 127 W = 100n + 151 Note 1) For more than 10 stations (more than 5 stations in case of SS5Y7), supply pressure to

B A B 2 position single 2 position double R1 R2 P R1 R2 P e y t r w w q q t r A B A B SY i SYJ R1 P R2 R1 P R2 i SX u 3 position closed center/exhaust center/pressure center VK 3 position closed center VZ A B w t q r R1 R2 P VF 3 position exhaust center A B A B VFR R1 R2 P VP7 3 position pressure center i A B VP4 R1 P R2 (This construction shows a closed center) R1 R2 P Component Parts Replacement

SYA w (B) 2 (A) 4 (A) 4 (B) 2 w y SYJA 1 (P) (EB)3 5(EA) VFA3000 VFA5000 VZA t (A)4 2(B) 3 (EB) 5 (EA) 1 (P) 5 (EA) 3 (EB) 1 (P) VFA VFA r y 1 (P) (EA)5 3(EB) VFRA 2 position double VPA4 Symbol 2 position double SYJA r t q q VFA1000 (B)2 4(A) w w (A) 4 (B) 2 (A) 4 (B) 2 VZA 5(EA) 1 (P) (EB)3 VTA VFA3000 VFA5000 2(B) (A)4 VGA 3 (EB) 5 (EA) 1 (P) 1 (P) 5 (EA) 3 (EB) t r (EA)5 1 (P) 3(EB) VPA

D1 M M A L1 D1 D2 L2 H Connection threads Male Branch: KPQU, KPGU (M5) Effective area mm D Model L TPH TPS A H (width across flats) (M5) 2-Applicable tubing Note1) Connection threads R Applicable tubing O.D. mm Weight g M P P M5 1/8 1/4 M5 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 KPQU04-M5 KPQU04-01 KPQU04-02 KPQU06-M5 KPQU06-01 KPQU06-02 KPQU08-01 KPQU08-02 KPQU10-02 KPQU10-03 KPQU12-03 KPQU12-04

A B C A B A B A B A B 15A 20A 25A Note 1) For each piping diameter for each body size, the second and later numbers or symbols indicate reducing.

Type A mounting bracket part no. YA-03 Joint YU-03 RS W M V T2 Joint Part No. 2-D through 2-O counterbore T1 B E J Applicable mounting bracket Bore size (mm) Weight (g) Joint part no.

4 (B) 2 (A) 4 (B) 2 1 W DC (42 mA), 0.5 W DC (21 mA) (3) 24 VDC 1 W DC (83 mA), 0.5 W DC (42 mA) Note (3) 12 VDC 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) Inrush 1.2 VA (12 mA), Holding 1.2 VA (12 mA) 100 VAC Power consumption (Current) 3 position pressure center 2 position double (Metal) Inrush 1.3 VA (11.7 mA), Holding 1.3 VA (11.7 mA) 110 VAC (A) 4 (B) 2 (A) 4 (B) 2 Inrush 2.4 VA (12 mA

91.9 A A A A B A B A B A B A Dimensions are the ones for SV1300--.

VBA22A-03 IR-A IR IRV 3/8" VEX SRH SRP VBA42A-04 VBA43A-04 (0.2 to 1.6 MPa) VBA40A-04 SRF ITV 1/2" IC ITVH ITVX Air Tank VBAT Series PVQ P.1022 VY1 Perfect fit with a booster regulator VBA VBAT VBA VBAT This is an air tank to which a booster regulator can be connected compactly.

Then confirm the locking by lightly pulling on the lead wire. w Disconnection For pulling out the socket from the connector, pull out the lead wire while pushing the hook of socket with a stick with a fine point(1mm).

Power saving circuit is not : SY100-30-A Without lead wire available in the case of W type.

How to Order Valve (Applicable to VQZ2000/3000 rubber seal) VQZ3151 5YZB 03 W IP65 rated No (Standard) (1) IP65 reted W Note 1) The pilot exhaust of the IP65 valves is common with main valve exhaust.