Magnet: Built-in, Mounting: Basic Style, Style: Non-lube Rubber Bumper, Bore Size: 100mm, Thread: Rc (M5 for Air Cushion 20 & 25 Bore), Seal Material: NBR, Stroke: 600mm, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, X Option: -
Magnet: Built-in, Mounting: Basic Style, Style: Non-lube Rubber Bumper, Bore Size: 100mm, Thread: Rc (M5 for Air Cushion 20 & 25 Bore), Seal Material: NBR, Stroke: 800mm, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, X Option: -
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Non-lube, rubber bumper, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Non-lube, rubber bumper, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Non-lube, rubber bumper, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 1000, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Non-lube, rubber bumper, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Non-lube, rubber bumper, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Non-lube, rubber bumper, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Non-lube, rubber bumper, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread
Magnet: Built-In, Mounting: Basic Type, Cushion: Non-lube, Rubber Bumper, Bore Size: 100mm, Thread: PT Ports, Seal Material: NBR, Stroke: 150mm, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, English Rod Thread: -
Thomas Oil-less Rotary Vane Compressor / Vacuum Pump Flow Rate: 33 LPM , 33 LPM, Max Pressure: 20.3 PSIG / 1400 mbar , 20.3 PSIG / 1400 mbar, Max Vacuum: 27.5 in HgV / -930 mbar , 27.5 in HgV / -930 mbar, Voltage (DC): 12, DC Motor Type: Standard, Item Dimensions: Length: 8.27 in / 210 mm Width: 2.32 in / 59 mm Height: 2.32 in / 59 mm , Length
Thomas Oil-less Rotary Vane Compressor / Vacuum Pump Flow Rate: 36 LPM , 36 LPM, Max Pressure: 20.3 PSIG / 1400 mbar , 20.3 PSIG / 1400 mbar, Max Vacuum: 24.8 in HgV / -840 mbar , 24.8 in HgV / -840 mbar, Voltage (DC): 24, DC Motor Type: Standard, Item Dimensions: Length: 8.27 in / 210 mm Width: 2.32 in / 59 mm Height: 2.32 in / 59 mm , Length
Operating range Cylinder mounting bracket, by stroke/ Auto switch mounting surfaces 80 301 to 1400 100 301 to 1500 Note 1) Manufacture of intermediate strokes at 1 mm intervals is possible. (Spacers are not used.) Note 2) Long stroke applies to the axial foot and rod flange types.
Unit: N Operating pressure (MPa) Bore size (mm) Operating direction Rod size (mm) Piston area (mm2) 0.5 0.6 0.4 0.3 756 630 504 378 OUT 1260 40 20 566 472 377 283 IN 943 1180 980 784 588 OUT 1960 50 20 990 825 660 495 IN 1650 1870 1560 1250 934 OUT 3120 63 20 1680 1400 1120 840 IN 2800 422 A Clamp Cylinder CK1 Series Construction CKG140, 50, 63 Rod mounting type #0 q @1 w e @2 @0 !4 y !
Opening Range of Throttle Valve and Driving Speed Conditions: Operating pressure 0.5 MPa, Horizontal mounting, No load, Spring return side The speeds shown in the graph are for reference. 40 40 1400 50 50 1200 Piston speed (mm/s) Related things about auto switches and the mounting brackets part numbers are the same as these of Series CV3.
Based on condition y; IDFS11E is selected as the model to process an air flow larger than 1400 l/min (ANR) with a 60Hz power supply, according to data D-2. 4 4 Note) l/min (ANR) is for reference conditions of 20C, 1 ATM and 65% relative humidity. Data A: Correction Factor for Temperature (Series IDUS) Inlet air temp. (C) Outlet air press. dew point (C) Ambient temp.
Based on condition y; IDFS11E is selected as the model to process an air flow larger than 1400 l/min (ANR) with a 60Hz power supply, according to data D-2. 4 4 Note) l/min (ANR) is for reference conditions of 20C, 1 ATM and 65% relative humidity. Data A: Correction Factor for Temperature (Series IDUS) Inlet air temp. (C) Outlet air press. dew point (C) Ambient temp.
D20Weight Rotating angle Flange (g) Basic weight (g) Add'l stroke weight (g/mm) Size 80 to 100 1400 4 500 32 170 to 190 1500 80 to 100 2100 40 5 500 170 to 190 2300 Calculation: (Example) MRQBS32-50CA Basic weight 1400 g 4 x 50 = 200 g Stroke additional weight Total 1600 g For the weight of auto switch alone, refer to page 11-11-1.
Opening Range of Throttle Valve and Driving Speed Conditions: Operating pressure 0.5 MPa, Horizontal mounting, No load, Spring return side The speeds shown in the graph are for reference. 40 40 1400 50 50 1200 Piston speed (mm/s) Related things about auto switches and the mounting brackets part numbers are the same as these of Series CV3.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 1490 1320 1650 1160 990 495 660 825 330 1650 IN 2810 2500 3120 2180 1870 936 1250 1560 624 3120 OUT 63 20 2520 2240 2800 1960 1680 840 1120 1400 560 2800 IN 4530 4020 5030 3520 3020 1510 2010 2520 1010 5030 OUT 80 25 4090 3630 4540 3180 2720 1360 1820