SMC Corporation of America
Elite Part Number Search
Search Results "CDJ2KD16-200Z-NW-A"

It is again necessary to connect a contact protection box in order to extend its life. Please contact SMC in this case. If driving a load such as a relay that generates a surge voltage, use a switch with a built-in contact protection circuit or use a contact protection box.

Heater: 8 XLC Series Dimensions XLC: Air operated (b) E C Size 16, 25, 40 E C E Fn (KF flange) (a) D Auto switch (Option) Heater (Option) (c) H J B A G A (b) C E Size 50, 63, 80 E C E Fn (KF flange) Fd (K flange) (a) D Heater (Option) Auto switch (Option) (c) H J K B A G A [mm] Model A B C D E*1 Fn Fd G H J K XLC-16-2 40 108 38 20 30 17 44 19 XLC-25-2 50 121 48 27 12 40 26 44 21 XLC-

Although a zener diode for surge protection is connected at the output side of a solid state auto switch, damage may still occur if a surge is applied repeatedly. When directly driving a load that generates surge, such as a relay or solenoid valve, use a switch with a built-in surge absorbing element. 8.

If driving a load such as a relay that generates a surge voltage, use a contact protection box. Although a zener diode for surge protection is connected at the output side of a solid state auto switch, damage may still occur if the surge is applied repeatedly.

Seal guide B Slide plate Spacer 21 22 Side seal unit MYMK-16-A MYMK-16-A MYMK-25-A MYMK-25-A MYMK-25-A 23 24 Hexagon socket head cap screw Chromated Chromium molybdenum steel 25 Replacement Parts: Seal Kit 20 40 50 25 32 63 16 No.

Seal guide B Slide plate Spacer Hexagon socket head cap screw MYMK-16-A MYMK-16-A MYMK-25-A MYMK-25-A MYMK-25-A Side seal unit Nickel plated Seal List No. !

Seal guide B Slide plate Spacer Hexagon socket head cap screw MYMK-16-A MYMK-16-A MYMK-25-A MYMK-25-A MYMK-25-A Side seal unit Nickel plated Seal List No. !

L L A A L A L A L A L L A Unit symbol RB 1412 with adjusting bolt RB 2015 with adjusting bolt RB 0806 with adjusting bolt RB 1007 with adjusting bolt RB 2015 with adjusting bolt RB 0806 with adjusting bolt RB 1412 with adjusting bolt With adjusting bolt With adjusting bolt With adjusting bolt With adjusting bolt With adjusting bolt With adjusting bolt With adjusting bolt Configuration and

2%4$2$4$5 @4 #0 Section A-A' 20A Data A' $0 $1 #4 #5 #2 @1 $6 $3 Component Parts No. Description Cam follower cap Magnet Magnet Seal magnet Rail End spacer Square nut Square nut Spring pin Parallel pin No.

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CJ2 ROUND BODY CYLINDER, GL, 16MM CJ2 NON-ROT AUTO-SW, 0.4957 lb

All three series, VQ, SX and SY, are c o m p a c t , l i g h t w e i g h t a n d a e s t h e t i c i n a p p e a r a n c e .

, d e t e r i o r a t i o n o f a c c u r a c y, a n d breakage of parts.)

Description Material Model Color Zinc die-cast AR10-A 1 Body White Aluminum die-cast AR20(K)-B to AR60(K)-B AR20K-B to AR60K-B (Regulator with Backflow Function) AR10-A Polyacetal White AR20(K)-B to AR40(K)-B 2 Bonnet A-A Aluminum die-cast AR50(K)-B/ AR60(K)-B y A Replacement Parts [AR10-A] 2 OUT 1 I N No. Description Material Part no.

Series CJ2 is auto switch capable Non-rotating rod type, Bore sizes: 10 and 16 *, Strokes from 15mm through 200mm, Mounts: basic, root, front flange, double clevis, Variety of switches and a variety of lead wire lengths, Cylinder, Air, ROUND BODY CYLINDER, 359, 0.12600 lb

Low Speed Auto switch model Bore size (mm) 20 25 32 40 50 63 80 100 D-M9(V) D-M9W(V) D-A9(V) MQ BMA3-020 (A set of a, b, c, d) BMA3-025 (A set of a, b, c, d) BMA3-032 (A set of a, b, c, d) BMA3-040 (A set of a, b, c, d) BMA3-050 (A set of a, b, c, d) BMA3-063 (A set of a, b, c, d) RHC D-M9A(V) Note 2) BMA3-020S (A set of b, c, d, e) BMA3-025S (A set of b, c, d, e) BMA3-032S (A set of b,

Modular Type Regulator AR Series AC-A Regulator AR Series AF-A Model Port size Options AF-A AR10-A M5 x 0.8 AR-A AR-A AL-A AR20-A 1/8, 1/4 AW-A Bracket AC-B AF-A AR25-A AF-A 1/4, 3/8 Round type pressure gauge AR -A -B AR30-A AL-A Set nut (for panel mount)* AW -A -B AR40-A 1/4, 3/8, 1/2 AW AG AR40-06-A 3/4 * For AR20-A to AR40-06-A, panel fitting dimensions are different from those of the

MY-S25 MY-S32 MY-S40 Applicable cylinder A 105 130 145 B 119 148 167 C 35 45 55 D 50 64 80 E 8 11.7 14.8 F 5 6 8.5 G 9.5 11 14 H 5.5 6.6 9 J M6 x 1 M8 x 1.25 M10 x 1.5 A B A B A B MY1H25 MY1H32 MY1H40 MY1 HT Side supports consist of a set of right and left supports.

M8 x 1.25 M10 x 1.5 Model Applicable cylinder MY3A16, MY3B16 MY3A25, MY3B25 MY3A40, MY3B40 MY3A63, MY3B63 A B A B A B A B MY-S16 MY-S25 MY-S32 MY-S40 63.6 Data 091 130 182 Guide for Using Side Support For long stroke operation, the cylinder tube may be deflected depending on its own weight and the load weight.

Use 0.3 to 0.7 times the thrust (differs depending on the operating speed) as a guide for actual use. g: Gravitational acceleration Dynamic moment Mounting orientation Dynamic load FE Horizontal Ceiling Wall Vertical Z M 1.4 100 x a x mn x g 1 3 a a ME x FE x Z Dynamic moment ME Dynamic moment ME does not occur. 1 3 mn x g ME M3 ME x FE x Y mn x g ME FE FE Note) Regardless of the mounting

Magnet: Built-in Magnet, Series: J2K, Mounting: Double Clevis, Bore Size: 16mm, Stroke: 100mm, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Rail Mounting