(When the allowable interval is specified for each cylinder series, use the indicated value.) 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (D-A6, A80, A80H, A90, A90V, C80, R80, 90, E80A, Z80).
(When the allowable interval is specified for each cylinder series, use the indicated value.) 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (D-A6, A80, A80H, A90, A90V, C80, R80, 90, E80A, Z80).
(When the allowable interval is specified for each cylinder series, use the indicated value.) 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (D-A6, A80, A80H, A90, A90V, C80, R80, 90, E80A, Z80).
(When the allowable interval is specified for each cylinder series, use the indicated value.) 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (D-A6, A80, A80H, A90, A90V, C80, R80, 90, E80A, Z80).
(Page 9) 6 Bushing (bearing) 1000 fR[N] 100 Lateral load applied to rod end 100 80 63 10 50 40 1 0 500 1000 1500 Cylinder stroke [mm] Fig. 1 Allowable lateral load applied to rod end C a u t i o n Be certain to align the rod axis with the load and direction of movement when connecting.
Center Q1 = 0.019 + 0.040 + 0.019 + 0.040 = 0.118 L(ANR) End Center End Center Air consumed in the tubing is calculated using formula (2), as shown below. 0.5 0.1 Q2 = 12.6 x 1000 x x 10-6 = 0.063 L(ANR) An entire stroke includes two rotations from end to center where the air is consumed. Thus, the total air consumption Q of the rotary table and tubing is obtained as shown below.
RS2H50, 63, 80 1.0 0.9 RS2H63 RS2H50 0.8 RS2H80 Operating pressure P [MPa] 0.7 0.6 0.5 0.4 0.3 0.2 0.1 1000 2000 3000 4000 0 5000 Lateral load F [N] Even after the impact of the carried object is absorbed, lateral load acts on the stopper cylinder due to the friction generated between the conveyor and the carried object.
Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 180mm, Thread: NPT, Stroke: 1000mm, Option: Cushion at Both Ends, Cylinder Switch Type: Y7PWV--Solid State, 2-color Indication, 3 Wire PNP, Vertical, Lead Wire or Pre-wired Connector: 3m Lead Wire, Number: 2 pcs. (Or None in the Case of
Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 180mm, Thread: NPT, Stroke: 1000mm, Option: Cushion at Both Ends, Cylinder Switch Type: Y7PWV--Solid State, 2-color Indication, 3 Wire PNP, Vertical, Lead Wire or Pre-wired Connector: 5m Lead Wire, Number: 2 pcs. (Or None in the Case of
Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 180mm, Thread: NPT, Stroke: 1000mm, Option: Cushion at Both Ends, Cylinder Switch Type: Y7PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 3m Lead Wire, Number: 2 pcs. (Or None in the
JIS B 8370: JIS B 8361: JIS B 9960-1: -(1 :) JIS B 8433-1993:*2) 1. 2. 3. 1. 2. 3. 4. 1 1 1 1 1 1.5 1.5 1.5 1.5 *3) *3) *3) *3) 1 1 1 1 1 1 1 1 () 2 , 2 2 2 2 3 , , ,, 4 , , , , , , , , , , , , 5m [] ,, , , , , , , , 5 ,, , , , , , , , , , , , , , 6 , 2 ,40mm, ON ON ON ON , ,: 1000 (ms) (mm) V(mm/s) = <> ,,(ON ) ,5m , ,30m, , <> ,100m <> (D-A96A96V ) ,,( ) [n ,n ] ,, ,, ,D-A90,A90V
C 0.2 B 0.2 0.1 A 0.2 0.05 100 1000 D (mm) MGPWM MGPWL/A Hexagon socket head cap screw 126 146 176 192 240 266 Maximum speed (mm/s) Bore size (mm) A (mm) B (mm) C (mm) 20 25 32 40 50 63 24 30 34 40 46 58 108 128 156 172 220 248 12 14 18 18 22 22 12 15 18 18 22 22 M5 x 0.8 M6 x 1.0 M8 x 1.25 M8 x 1.25 M10 x 1.5 M10 x 1.5 Other Caution Do not use this cylinder as a stopper. 518
MK2T Max. piston speed Average piston speed Note 1) Total stroke Note 2) Stroke time Note 3) Model MK 115 mm/s 72 mm/s 25 mm 0.35 seconds CK1 1.0 x 104 Note 1) Average piston speed = Max. piston speed 1.6 Note 2) Total stroke = Clamp stroke + Rotary stroke Note 3) Total stroke Average piston speed The stroke time should be longer than the above mentioned stroke time. 115 200 CLK2 10 100 1000
Nominal Size: 16, Speed Specifications: Standard 100 to 1000, Load Specifications: Standard Load, Nominal Size: 16(5), 25(10), Stroke: 700mm, Motor Placement: TA [On the Top (Left)], Output Type: PNP, Stoppable Positioning Points: 3 Point (2 Ends + 1 Intermediate), Cable Length: None, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: 3m Lead Wire, Number: -, CE
Nominal Size: 16, Speed Specifications: Standard 100 to 1000, Load Specifications: Standard Load, Nominal Size: 16(5), 25(10), Stroke: 700mm, Motor Placement: TB [On the Top (Right)], Output Type: PNP, Stoppable Positioning Points: 3 Point (2 Ends + 1 Intermediate), Cable Length: None, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: 3m Lead Wire, Number: -, CE
Guide Suffix: Single Axis, Nominal Size: 16, Speed Specifications: Standard 100 to 1000, Load Specifications: Standard Load, Nominal Size: 16(5), 25(10), Stroke: 150mm, Motor Placement: On the Top, Symmetric, Output Type: NPN, Stoppable Positioning Points: 3-point Stoppable, Cable Length: 1 m, Auto Switch: A90--Reed, DC Volt >5<24, AC Volt <100, LED, 2 Wire, Lead Wire or Prewired Connector
Guide Suffix: Single Axis, Nominal Size: 16, Speed Specifications: Standard 100 to 1000, Load Specifications: Standard Load, Nominal Size: 16(5), 25(10), Stroke: 150mm, Motor Placement: On the Top, Symmetric, Output Type: PNP, Stoppable Positioning Points: 3-point Stoppable, Cable Length: 1 m, Auto Switch: A90--Reed, DC Volt >5<24, AC Volt <100, LED, 2 Wire, Lead Wire or Prewired Connector
Guide Suffix: Double Axis, Nominal Size: 16, Speed Specifications: Standard 100 to 1000, Load Specifications: Standard Load, Nominal Size: 16(5), 25(10), Stroke: 150mm, Motor Placement: On the Top, Symmetric, Output Type: NPN, Stoppable Positioning Points: 5-point Stoppable, Cable Length: 1 m, Auto Switch: A90--Reed, DC Volt >5<24, AC Volt <100, LED, 2 Wire, Lead Wire or Prewired Connector
Guide Suffix: Single Axis, Nominal Size: 16, Speed Specifications: Standard 100 to 1000, Load Specifications: Standard Load, Nominal Size: 16(5), 25(10), Stroke: 150mm, Motor Placement: On the Top, Symmetric, Output Type: NPN, Stoppable Positioning Points: 5-point Stoppable, Cable Length: 3 m, Auto Switch: A90--Reed, DC Volt >5<24, AC Volt <100, LED, 2 Wire, Lead Wire or Prewired Connector
Guide Suffix: Single Axis, Nominal Size: 16, Speed Specifications: Standard 100 to 1000, Load Specifications: Standard Load, Nominal Size: 16(5), 25(10), Stroke: 150mm, Motor Placement: On the Top, Symmetric, Output Type: NPN, Stoppable Positioning Points: 5-point Stoppable, Cable Length: 1 m, Auto Switch: A90--Reed, DC Volt >5<24, AC Volt <100, LED, 2 Wire, Lead Wire or Prewired Connector