Selection Graph [Graph 2] Allowable load mass by stroke 10 [Graph 1] Allowable load mass by stroke 6 10 10 Load mass [kg] Load mass [kg] y, z + A 200 y, z + A 300 y, z + A 100 1 1 0 100 200 300 400 500 600 0 100 200 300 400 Stroke [mm] Stroke [mm] [Graph 4] Allowable load mass by stroke 20 [Graph 3] Allowable load mass by stroke 15 100 10 y, z + A = 0 Load mass [kg] Load mass [kg] y, z
NBR Valve seal Tube gasket Standard (non-lube) Piston gasket 125 140 160 180 200 250 300 CS1N125A-PS CS1N140A-PS CS1N160A-PS CS1N180A-PS CS1N200A-PS CS1N250A-PS CS1N300A-PS Retaining plate gasket Guide gasket Component part numbers: @3, @5, @6, @7, @8, #0. Seal kit includes a grease pack (125 to 160: 40 g, 180 and 200: 50 g, 250 and 300: 60 g).
Up to 300 Up to 300 50 35 32 Up to 300 63 80 100 50 40 40 35 H A 8 6 6 5 H1 47 38 31 26 I 13<10> 20<18> 20 20 GA 19 17 17 13 B1 6 5.5 5.5 5 K 44 35.5 29 24 NA 9 7 7 7 RA 26 20 16.5 14 C 130 121 119 114 ZZ 14 10 8 6 KA 78 79 77 77 S 16 12 10 8 D 25 18 14 12 E 2 2 2 2 F 40 32 25 20 30 22 22 18 23 0<23> 0 0 10 0 0 0 M5 x 0.8 depth 7.5 M5 x 0.8 depth 8 M14 x 1.5 M6 x 1 depth 12 12 12 1/4 1/4
0.1 0.06 1 0.1 0.02 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 Technical Data Piston speed mm/s Piston speed mm/s Piston speed mm/s Piston speed mm/s 1187 Mechanically Jointed Rodless Cylinder Basic Type 25, 32, 40 MY1B Series RoHS How to Order M9BW 25 Z 300 MY1B Basic type Made to Order Refer to page 1189 for details
500 1000 1500 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 Piston speed mm/s Piston speed mm/s Piston speed mm/s Piston speed mm/s Technical Data 1207 Mechanically Jointed Rodless Cylinder Linear Guide Type MY1H Series 25, 32, 40 RoHS How to Order M9BW 25 300 MY1H Z Linear guide type Linear guide type Made to Order Refer to page 1209 for details
, 400, 500 750 15 1 axis 200, 300, 400, 500, 600, 800 25 1200 25 200, 300, 400, 500, 600, 800, 1000 2 axes 1500 32 Note 1) Strokes exceeding the standard strokes are available as a special order.
Load (kg) Load (kg) 10 10 30 10 100 300 Speed (mm/s) Speed (mm/s) Speed (mm/s) 300 300 REA REB Stroke Stroke Speed REC CY Time Time Stroke P=0.5 MPa,M=10 kg P=0.3 MPa,M=10 kg M=10 kg M=30 kg V=300 mm/s V=100 mm/s CX MQ Model Recommended Speed Controllers Caution RHC RZQ Model Elbow type Straight type In-line type REC20 AS2201F-01-06-X214 AS2001F-06-X214 AS2301F-01-06-X214 REC25 AS2201F
Load (kg) Load (kg) 10 10 30 10 100 300 Speed (mm/s) Speed (mm/s) Speed (mm/s) 300 300 REA REB Stroke Stroke Speed REC CY Time Time Stroke P=0.5 MPa,M=10 kg P=0.3 MPa,M=10 kg M=10 kg M=30 kg V=300 mm/s V=100 mm/s CX MQ Model Recommended Speed Controllers Caution RHC RZQ Model Elbow type Straight type In-line type REC20 AS2201F-01-06-X214 AS2001F-06-X214 AS2301F-01-06-X214 REC25 AS2201F
0 100 200 300 100 200 300 (1N = Approx. 0.102kgf) Load N Load N (1N = Approx. 0.102kgf) Load N (1N = Approx. 0.102kgf) 25 25 25 Lr = 200mm 0.08 MXQ25-50 MXQ25-75 MXQ25-10 MXQ25-20 MXQ25-30 MXQ25-40 MXQ25-150 MXQ25-40 0.12 0.10 MXQ25-75 MXQ25-125 MXQ25-100 MXQ25-75 MXQ25-40 MXQ25-150 MXQ25-100 MXQ25-100 MXQ25-125 MXQ25-150 Table displacement mm Table displacement mm Table displacement mm
300 300 200 200 Lower limit 100 100 Lower limit 0 0 10 20 30 40 0 10 20 30 40 0 Transfer speed [m/min] Transfer speed [m/min] RS2H63-30 The graphs indicate the values at normal temperature. (20 to 25C) = 0.2 = 0.1 1,000 900 800 700 600 500 400 300 200 100 0 1,000 900 800 700 600 500 400 300 200 100 0 Mass of transferred object m [kg] Mass of transferred object m [kg] 63 Operating range
QW RW T W X Y Z Bore size (mm) S 140 32 60 33 19 157 33 10.5 7.5 40 84 35 180 21 187 39.5 11 8 Long Stroke X Y Z Bore size (mm) Stroke range (mm) 32 125, 150, 175, 200, 250, 300 45.5 12.5 12.5 40 125, 150, 175, 200, 250, 300 55 14 14 8-27-9 10 Series CXT Proper Auto Switch Mounting Position (Detection at stroke end) and Its Mounting Height Reed switch Solid state switch A B W D-A9 D-M9 D-F9BAL
distance l (mm) 10 400 Eccentric distance l (mm) MGTL100 300 200 300 MGTM100 200 P = 0.5 MPa 100 P = 0.5 MPa Load weight m(kg) Larger than 75st Load weight m(kg) 40 50 100 Larger than 50st 50st 25st 30 25, 50st 20 50 40 10 30 5 4 3 2 20 1 10 20 30 40 50 100 200 300 1 2 3 4 5 10 20 304050 100 200 300400 Eccentric distance l (mm) 10 400 Eccentric distance l (mm) Allowable side load F(N) 1
4.95 5.99 6.85 7.70 8.55 50 MGPM50 3.36 4.00 4.73 5.37 6.01 6.65 7.29 7.93 9.54 10.8 12.1 13.4 63 MGPM63 4.18 4.94 5.78 6.54 7.29 8.05 8.80 9.56 11.4 12.9 14.4 15.9 80 MGPM80 6.49 7.43 8.67 9.61 10.5 11.5 12.4 13.4 15.8 17.7 19.5 21.4 100 MGPM100 10.5 11.9 13.6 14.9 16.3 17.6 18.9 20.2 23.6 26.2 28.9 31.5 (kg) MGPL12100/MGPA12100( (mm) (mm) 10 20 25 30 40 50 75 100 125 150 175 200 250 300
100, 125, 150, 175, 200, 250, 300, 400, 500 32 131 90 27 16 45 49.5 64 M14 X 1.5 14 4.5 14 40 177 136 27 16 52 57 71.5 M14 X 1.5 24 5 14 50 63 200, 300, 500 193 144 32 20 64 71 85.5 M18 X 1.5 22.5 7 18 200, 300, 500 194 145 32 20 77 84 98.5 M18 X 1.5 21 7 18 P T* X M N O Q Z L Bore size (mm) 32 40 50 63 Rc(PT) 1/8 57.5 41 34 5.5 M6 X 1 56 30 14 Rc(PT) 1/8 64.5 41 40 5.5 M6 X 1 62 30 14 Rc
150 600 300 150 1000 500 250 800 400 200 Different from the initial value. *5.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Additional cylinder tube length Full stroke RHC CDQ2 MK(2) RS Q G Overall length of cylinder tube RS H A Comparison of cylinder tube overall length (mm) RZQ Full stroke = 300 mm (150 + 150 = 300 mm in case of CG1BN) MI W S CG1BN150+150-XC11 Dual stroke
3 Position Cylinder 2-stage stroke enabled with a small increase in length Provides intermediate stop mechanism Overall length of cylinder tube RZQ First-stage stroke Additional cylinder tube length Full stroke CDQ2 Overall length of cylinder tube Series RZQ 32, 40, 50, 63 Comparison of cylinder tube overall length (mm) Full stroke = 300 mm (150 + 150 = 300 mm in case of CG1BN) CG1BN150
(When the allowable interval is specified for each cylinder series, use the indicated value.) 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (D-A6, A80, A80H, A90, A90V, C80, R80, 90, E80A, Z80).
Double acting 125, 140 160, 180 200 Double rod CQ2W 7-6-115 10 to 300 Long Stroke 32, 40, 50 63, 80, 100 Single rod CQ2 Double acting 7-6-121 125 to 300 Anti-lateral Load Single rod CQ2S 32, 40, 50 63, 80, 100 Double acting 32 to 40/5 to 100 50 to 100/10 to 100 7-6-132 With End Lock 20, 25, 32 50, 63, 80 100 Single rod CBQ2 Double acting 20 to 63/10 to 100 80, 100/25 to 100 7-6-142 Air-hydro
Indicator light Lead wire Flexible fluorine resin heavy-duty cable, 6, 0.5mm2, 2 cores, 300 mm Impact resistance Switch part : 1000 m/s2, Connector part : 300 m/s2 Insulation resistance 50 M or more at 500 VDC (between lead wire and case) Withstand voltage 1000 VAC for 1 minute (between lead wire and case) Ambient temperature 10 to 60C Enclosure IEC529 standard IP67, JIS 0920 Watertight