SMC Corporation of America
Elite Part Number Search
Search Results "CDNA2L50-800-D-A93"

/Y7PV D-Y7W/Y7WV D-Y7BA D-Y59/Y69 D-Y7P/Y7PV D-Y7W/Y7WV D-Y7BA 5 5 5 5.5 5.5 5 5 5 5.5 5.5 Perpendicular electrical entry type and D-Y7BAL cannot be mounted on 16, 20, 50 and 63.

Auto Switch Proper Mounting Position for Stroke End Detection MY1CW 16, 20 MY1MW 16, 20 B A Reed switch D-A90(V), D-A93(V), D-A96(V) Solid state switch D-F9N(V), D-F9P(V), D-F9B(V) D-F9NW(V), D-F9PW(V), D-F9BW(V) Mounting position 20 16 20 16 20 Mounting position Mounting position 16 A 90 70 93 73 94 A A 74 B 110 90 107 87 106 B B 86 Operating range Note) 7.5 11 6.5 8.5 6.5 Operating range

Technical Data 1219 MY1H Series Auto Switch Mounting Auto Switch Proper Mounting Position Auto Switch Proper Mounting Position (mm) D-M9 D-M9V D-M9W D-M9WV D-M9AL D-M9AV Auto switch model D-A9 D-A9V A A Bore size A A 25 32 40 81 85 112.5 116.5 133.5 137.5 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.

(mm) D-A90V D-A96V D-A93V 22 Bore size D-M9V D-F9WV D-M9 D-F9W D-A90 D-A96 D-A93 (mm) 32 20 32 Mounting pattern q, w 35 Mounting pattern e 20 12 Mounting of Auto Switch As shown below, there are 3 ways to mount the auto switch according to 3 types of electrical entries. Insert the auto switch into the switch groove.

freezing) Bearing type Ball spline Rubber bumper Cushion Air cushion Effective cushion length (mm) 11 12 9 10 17 17 Lubrication Non-lube Reed switch: D-A9 Solid state switch: D-F9 D-F8 Reed switch: D-A9 Solid state switch: D-F9 Auto switches +1.0 0 Stroke tolerance mm 0.1 or less (within allowable torque values) 0.2 or less (within allowable torque values) Non-rotating accuracy Port size

Adjuster Option: Stroke Adjustment Range Extension end (AS) Bore size Suction flow rate L/min (ANR) Stroke adjustment range 0 to 5 mm Retraction end (AT) 6, 8, 12 1 Rubber stopper Both ends (A) 16 2 Extension end (CS) 20 3 Stroke adjustment range 0 to 5 mm Retraction end (CT) 25 5 Metal stopper Both ends (C) Proper Auto Switch Mounting Position (Detection at Stroke End) E A B Reed auto switch: D-A93

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Magnet: Built-in Magnet, Mounting: Axial Foot, Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 800mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 5m, Number: -, Made to Order: -

Magnet: Built-in Magnet, Mounting: Axial Foot, Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 800mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: F5P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire or Prewired Connector: 5m, Number: 1 pc., Made to Order: -

Magnet: Built-in Magnet, Mounting: Axial Foot, Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 800mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Made to Order: -

Magnet: D (Built-in Magnet), Mounting: L (Axial Foot), Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 800mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), Mounting: L (Axial Foot), Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 800mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), Mounting: L (Axial Foot), Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 800mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)

Magnet: D (Built-in Magnet), Mounting: L (Axial Foot), Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 800mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: Z (5m)