If this is not done, the tie-rods or piston rod assembly will be damaged. 75
Series C96 How to Mount and Move the Auto Switch 1 Tie-rod Mounting Type Mounting Bracket
For details, refer to page 443. 413
CHA Series How to Mount and Move the Auto Switch
BQ-1 BQ-2 BQ2-012 Weight (g) 1.5 1.5 5 259
CHQB/CHQWB Series How to Mount and Move the Auto Switch
Low friction type (CDS1Q): 125, 140, 160 Auto Switch Mounting Height (mm) D-F5 D-J5 D-F5W D-J59W D-F5BAL D-F59F D-F5NTL Hs Auto switch model D-Z7/Z80 D-Y5/Y6 D-Y7P D-Y7PV D-Y7W D-Y7WV D-Y7BAL Hs D-A9 D-A9V D-M9 D-M9W D-M9AL D-M9V D-M9WV D-M9AVL D-A3 D-G39 D-K39 D-A5 D-A6 D-A59W D-A44 DHs Ht Hs Hs Hs Ht Ht Ht Ht Ht Bore size 125 140 160 180 200 69 69.5 71.5 69.5 69 69.5 116 126 75.5 69.5 74.5
Auto Switch Mounting Height (mm) D-F5 D-J5 D-F5W D-J59W D-F5BAL D-F59F D-F5NTL Hs D-Z7/Z80 D-Y5/Y6 D-Y7P D-Y7PV D-Y7W D-Y7WV D-Y7BAL Hs Auto switch model D-A9 D-A9V D-M9 D-M9W D-M9AL D-M9V D-M9WV D-M9AVL D-A3 D-G39 D-K39 D-A5 D-A6 D-A59W D-A44 Hs Hs Ht Hs Hs Hs Ht Ht Ht Ht Bore size 125 140 160 69 69.5 69 71.5 116 126 75.5 74.5 69.5 69.5 69.5 70 76 76 76 77.5 124 134 81 80 76 76 76.5 76.5
to 63. 145
Auto Switch Mounting CP96 Series How to Mount and Move the Auto Switch
(mm) Auto switch model Bore size Bore size Auto switch model 20 to 32 40 to 80 63 80 D-A9/A9V 20 25 32 40 50 8 9.5 8 8 8.5 9.5 9.5 D-A9/A9V D-M9/M9V D-M9W/M9WV D-M9AL/M9AVL Note) q BMP1-032 w BMG2-012 D-M9/M9V D-M9W/M9WV D-M9AL/M9AVL BMY3-016 4.5 4.5 5 5 5 6.5 6 D-Z7/Z80 D-Z7/Z80 D-Y5/Y7P D-Y7W D-Y6/Y7PV D-Y7WV D-Y7BAL 10 10 11 13 D-Y59/Y69 D-Y7P/Y7PV D-Y7W/Y7WV D-Y7BAL q BMP1-032 6 5 6
D-M9BW(V), D-M9NW(V), D-M9PW(V) Stroke (mm) 20 41 29 41 29 47 35 Stroke (mm) Model Model Normally closed (NC = b contact) solid state auto switches (DF9G/F9H types) and a solid state auto switch (D-F8) are also available.
Auto Switch Proper Mounting Position (at Stroke End Detection) Center of magnet A D-M9m, D-M9mV D-M9mW, D-M9mWV (mm) D-A9, D-A9mV (mm) A Operating range Bore size 16 25 A Operating range Bore size 16 25 30 9 34 4.5 30 9 34 4.5 Note) Only adjust the setting position after confirming the auto switch is properly activated.
Material: Carbon steel 20 Series MU Auto Switch Proper Mounting Position (Detection at stroke end) and Mounting Height D-M9 D-M9W D-M9AL D-A9 D-M9V D-M9WV D-M9AVL D-A9V B B A A Hs Hv D-M9 D-M9W D-M9AL D-M9V D-M9WV D-M9AVL D-A9 D-M9V D-M9WV D-M9AVL Size A B A B Hs Hv A B A B Hs Hv 25 5 5 5 5 7.5 27.5 1 1 1 1 32 5 5 5 5 14.5 30 1 1 1 1 40 5.5 5.5 5.5 5.5 16.5 37 1.5 1.5 1.5 1.5 50 7
Single round shaft: ClRA1BT Double shaft (round shaft, with four chamfers): ClRA1BJ Double round shaft: ClRA1BK D D D H H H H UU UU M N 0 0.2 G D L 0 0.2 [mm] [mm] [mm] Size D (g6) H Size D (g6) G H M N UU L Size D (g6) H UU 30 8 25 50 15 36 63 17 41 80 20 50 100 25 60 30 8 6 25 10 8 75 7.8 50 15 11 36 20 15 118 14 63 17 13 41 22 17 139 16 80 20 15 50 25 20 167 19 100 25 19 60 30 25 202 24
Minimum Stroke for Auto Switch Mounting (mm) 12 16 20 25 32 40 50 63 80 100 Auto switch model No. of auto switches mounted 1 pc. 10 5 D-A9 2 pcs. 15 10 D-A9V D-M9V 1 pc. 5 2 pcs. 10 1 pc. 15 10 5 D-M9 2 pcs. 15 10 1 pc. 15 10 D-M9W 2 pcs. 15 10 1 pc. 10 D-M9WV 2 pcs. 10 D-Z7 D-Z80 1 pc. 10 5 2 pcs. 15 10 D-Y59 D-Y7P 1 pc. 5 10 2 pcs. 15 10 D-Y69 D-Y7PV 1 pc. 5 2 pcs. 5 D-Y7W D-Y7WV 1 pc.
Solid State Auto Switch: D-M9B, D-M9N, D-M9P, D-M9BW, D-M9NW, D-M9PW Stroke B Stroke E Model A 40 50 150 10 20 30 40 75 100 125 150 10 20 30 125 75 100 50 B MXS6 -0.4 -0.4 -0.4 11.6 17.5 9.6 9.6 9.6 21.6 27.6 10 MXS8 4.9 -0.1 0.9 8.9 16.9 41.9 14.9 9.9 10.9 18.9 51.9 26.9 11.6 MXS12 32.4 22.4 12.4 14.4 45.4 74.4 24.4 22.4 12.4 2.4 4.4 14.4 35.4 64.4 15.6 MXS16 32.7 22.7 12.7 12.7 42.7
Applicable model: D-A73, A73H, A73C, C73, C73C, E73A, Z73 D-R73, R73C, 97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) When using a 2-color indicator type auto switch (D-A79W, A59W and B59W), the auto switch will constantly remain ON if the connections are reversed.
(between case and cable) Ambient temperature -10 to 60 C Enclosure IEC 60529 criteria IP67, JISC0920 watertight construction -23No.D-S-OMJ0004-G D-M9BW(V)/D-M9NW(V)/D-M9PW(V) PLC: Programmable Logic Controller Switch part no.
Applicable model: D-A73, A73H, A73C, C73, C73C, E73A, Z73 D-R73, R73C, 97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) When using a 2-color indicator type auto switch (D-A79W, A59W and B59W), the auto switch will constantly remain ON if the connections are reversed.
LAT LEJS40 LEJS63 Applicable auto switches D-M9N(V)-900, D-M9P(V)-900, D-M9B(V)-900 D-M9NW(V)-900, D-M9PW(V)-900, D-M9BW(V)-900 LZ *4 Please consult with SMC for non-standard strokes as they are produced as special orders. LC3F2 * Specifications and dimensions for the 25A-series are the same as standard products.
M9B D-M9B M9N D-M9N Solid state switch M9P D-M9P M9BW D-M9BW Solid state switch (2-color indication) M9NW D-M9NW M9PW D-M9PW *Note 1) lead wire length symbols 0.5mNil. (Case) M9NW 1mM (Case) M9NWM 3mL (Case) M9NWL 5mZ (Case) M9NWZ *Note 2) When 2 auto-switches are specified they are assembled for shipping.
M9B D-M9B M9N D-M9N Solid state switch M9P D-M9P M9BW D-M9BW Solid state switch (2-color indication) M9NW D-M9NW M9PW D-M9PW *Note 1) lead wire length symbols 0.5mNil. (Case) M9NW 1mM (Case) M9NWM 3mL (Case) M9NWL 5mZ (Case) M9NWZ *Note 2) This product can be mounted on the NEXTAGE KAWADA ROBOTICS CORPORATION. 3-2.
Mounting Height Auto Switch Proper Mounting Position (mm) D-Y59< D-Y69< D-Y7P D-Y7PV D-Y7