SMC Corporation of America
Elite Part Number Search
Search Results "CDQSWB12-20D-M9PW"

, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~0.7, Cushion: Rubber cushion, Port thread type: M5 × 0.8, Auto Switches: M9PW

Method: Double Acting, Main Body Shape: Square Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 42, Gripping Force (Open Side at 0.5 Mpa)(N): 66, Environment, Applications: Standard, Additional Function: With Linear Guide, Stroke Adjustment Mechanism: Not Provided, Cylinder internal diameter(mm): 20, Finger position / Options: Standard basic type, Body options: Basic type, Auto switch: M9PW

Bore Size: 20mm, Action: Double Acting, Finger Option: Basic Style, Body Option: Basic Style, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: -, Number: -, Made-to-Order: -

Magnet: Built-in, Bore Size: 50mm, Port Thread: Screw-in Piping, Stroke: 20mm, Action: Double Acting, Rod End Configuration: Round Bar Style, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -

Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: Double Acting, Rod End: Round Bar Style, Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in Magnet, Bore Size: 10 mm, Port Thread: Bore 6~25:M5, Bore 32: Rc 1/8, Stroke: 20 mm, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in Magnet, Bore Size: 16 mm, Port Thread: Bore 6~25:M5, Bore 32: Rc 1/8, Stroke: 20 mm, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Lead Wire or Prewired Connector: -, Number: -

Bore Size: 20mm, Finger Option: Standard Tap Mounting, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in Magnet, Bore Size: 10, Port Thread: Bore: 6, 10, 16, 20, 25, M5x0.8 ; Bore: ø32, Rc1/8, Stroke: 20mm, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in Magnet, VAC Side Tube/Rod End Shape: Cap Piping/Male Thread, Bore Size: 16mm, Port Thread: M5x0.8 (Bore 10, 16, 20, 25), Rc1/8 (Bore 32), Stroke: 20mm, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Through Hole, Both Ends Tapped, Bore Size: 12mm, Stroke: 20mm, Option: Standard(Rod End Female Thread), Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: -, Number: -, Thread: -

Magnet: Built-in, Mounting: Through Hole, Both Ends Tapped, Bore Size: 20mm, Stroke: 20mm, Option: Standard(Rod End Female Thread), Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: -, Number: -, Thread: -

Magnet: Built-in, Mounting: Through Hole, Both Ends Tapped, Bore Size: 25mm, Stroke: 20mm, Option: Standard(Rod End Female Thread), Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: -, Number: -, Thread: -

Bore Size: 20mm, Action: D (Double Acting), Finger Option: Basic Style, Body Option: Basic Style, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø6 mm, Stroke: 20 mm, Rod End Thread: With Thread, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, 0.5M

Operates smoothly with minimal stick-slip. 0.01 0.01 0.1 RZQ 1 10 Cylinder operating conditions Particle diameter (m) MI W S 10-CM2XB20-50 CEP1 CJ2XB10-60 CQSXB20-20D Evaluation of air purity inside chamber 100 Air cleaning system Particle concentration (particles/cf) Average speed 0.85 mm/s Average speed 0.88 mm/s 2.0 CE1 Average speed 0.43 mm/s Average speed 0.43 mm/s 2.0 Speed (mm/s) Displacement

Different sides RB D-A44C n Same side J 10 75 80 90 1 2 (Different sides, Same side), 1 D85 90 95 105 15 80 D-Z7/Z80 D-Y59/Y7P D-Y7W (n 2) 2 15 + 40 n = 2, 4, 6, 8 (n 4) 2 (n 4) 2 (n 4) 2 (n 4) 2 (n 4) 2 105 + 40 95 + 40 n = 4, 8, 12, 16 90 + 40 n = 4, 8, 12, 16 85 + 40 n = 4, 8, 12, 16 80 + 40 n = 4, 8, 12, 16 n -X n = 4, 8, 12, 16 2 (Different sides, Same side), 1 75 80 90 10 65 20D-Y69

Test range Thermometer Test equipment Pressure tap Pressure tap Throttle valve on the upstream side Flow meter Throttle valve on the downstream side 2d 6d 20d 10d Fig. (3) Test circuit based on IEC60534-2-3, JIS B 2005 12 VXB Series Flow Rate Characteristics Note) Use this graph as a guide. If an accurate flow rate is required, refer to pages 8 to 12.

VXZ VXS VXB Test range Thermometer VXE Equipment for test Pressure tap Pressure tap VXP VXR Throttle valve in the downstream side Flow meter Throttle valve in the upstream side VXH 2d 6d VXF 20d 7d VX3 Fig. (3) Test circuit based on IEC60534-2-3, JIS B 2005-2-3 VXA 100 100 Saturated steam flow rate Q0 [kg/h] (when Kv = 1) Upstream pressure Water flow rate Q0 [L/min] (When Kv = 1) 50 40

Test range Thermometer Equipment Pressure Pressure for test tap tap Restrictor Flow Restrictor on the 2d 6d on the meter downstream side upstream side r 20d r 10d Fig. (3) Test circuit based on IEC60534-2-3, JIS B 2005 32 Series VXN Flow-rate Characteristics Note) Use this graph as a guide. In the case of obtaining an accurate flow rate, refer to pages 28 through to 32.