SMC Corporation of America
Elite Part Number Search
Search Results "CLSL125-1600-D"

Magnet: None, Mounting: Foot, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: Rc, Stroke: 1200mm, Option: -, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -

Magnet: None, Mounting: Foot, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: Rc, Stroke: 1000mm, Option: -, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 130, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 1400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

D The setting time from when the input signal reaches the set value, to when the ON-OFF output actually begins working. Delay time setting can prevent the output from chattering. Delay time Shows how precisely the flow can be displayed or set by the digital flow switch.

Magnet: D (Built-in), Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 200 (2"), Stroke: 1600 (16"), Air Cushion: Both Ends (Air Cushion), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: N (No Lead Wire), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XB9 [Low Speed Cylinder (10~50mm/s)]

Magnet: D (Built-in), Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 325 (3 1/4"), Stroke: 1600 (16"), Air Cushion: Both Ends (Air Cushion), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: N (No Lead Wire), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XB9 [Low Speed Cylinder (10~50mm/s)]

Magnet: D (Built-in), Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 250 (2 1/2"), Stroke: 1600 (16"), Air Cushion: Both Ends (Air Cushion), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: N (No Lead Wire), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XB9 [Low Speed Cylinder (10~50mm/s)]

Magnet: D (Built-in), Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 250 (2 1/2"), Stroke: 1600 (16"), Air Cushion: Both Ends (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC6 (Stainless Steel Rod)

Magnet: D (Built-in), Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 325 (3 1/4"), Stroke: 1600 (16"), Air Cushion: Both Ends (Air Cushion), Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.), X Option: XC6 (Stainless Steel Rod)

Magnet: D (Built-in), Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 325 (3 1/4"), Stroke: 1600 (16"), Air Cushion: Both Ends (Air Cushion), Auto Switch: A64--Reed, DC Volt >5<24, AC Volt <200, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.), X Option: XC6 (Stainless Steel Rod)

Magnet: D (Built-in), Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 200 (2"), Stroke: 1600 (16"), Air Cushion: Both Ends (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC22 (Viton Seals)

Magnet: D (Built-in), Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 150 (1 1/2"), Stroke: 1600 (16"), Air Cushion: Both Ends (Air Cushion), Auto Switch: A53--Reed, DC Volt >5<24, LED, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC6 (Stainless Steel Rod)

Magnet: D (Built-in), Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 400 (4"), Stroke: 1600 (16"), Air Cushion: Both Ends (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC6 (Stainless Steel Rod)

Magnet: D (Built-in), Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 150 (1 1/2"), Stroke: 1600 (16"), Air Cushion: Both Ends (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC6 (Stainless Steel Rod)

Magnet: D (Built-in), Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 200 (2"), Stroke: 1600 (16"), Air Cushion: Both Ends (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC6 (Stainless Steel Rod)

Magnet: D (Built-in), Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 250 (2 1/2"), Stroke: 1600 (16"), Air Cushion: Both Ends (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC35 (with Coil Scraper)

Magnet: D (Built-in), Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 250 (2 1/2"), Stroke: 1600 (16"), Air Cushion: Both Ends (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.

Magnet: D (Built-in), Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 325 (3 1/4"), Stroke: 1600 (16"), Air Cushion: Both Ends (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC35 (with Coil Scraper)