Bore Size: 32mm, Stroke: 10mm, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Rated Voltage: 5 (24VDC), Electrical Entry: MO (M-type plug connector w/o connector), Surge Voltage Suppressor: S (With surge voltage suppressor)
Bore Size: 32mm, Stroke: 10mm, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Rated Voltage: 5 (24VDC), Electrical Entry: M [M-type plug connector w/lead wire (300mm)], Surge Voltage Suppressor: S (With surge voltage suppressor)
Bore Size: 32mm, Stroke: 10mm, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Rated Voltage: 5 (24VDC), Electrical Entry: M [M-type plug connector w/lead wire (300mm)], Surge Voltage Suppressor: R [With surge soltage suppressor (Non-polar)]
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.7, Port thread type: -, Auto
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.7, Port thread type: -, Auto
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.7, Port thread type: -, Auto
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.7, Port thread type: -, Auto
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.7, Port thread type: -, Auto
Mounting: Through Hole, Bore Size: 40mm, Stroke: 100mm, Option: Standard (Rod End Female Thread), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Rated Voltage: 24 VDC, Electrical Entry: M Plug Connector With Lead Wire, Surge Voltage Suppressor: U [Light/Surge Suppressor (Non-Polar Type
Mounting: B (Through Hole), Bore Size: 40mm, Stroke: 100mm, Option: Standard (Rod End Female Thread), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Connector With Lead Wire), Surge Voltage Suppressor: U [Light/Surge Suppressor
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT GUIDE ROD W/VALVE, ACTUATOR, CVQM CYL, GUIDE ROD W/VALVE, PE, 63MM CVQM DBL ACTING, AUTO-SW, 3.96832 lb
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 63mm, Port Thread Type: TF (G), Stroke: 50mm, Body Option: Rod End Female Threads, Standard, Locking Direction: F (Extension Locking), By-Pass Piping: None (Emergency Stop), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: M (1m)
Magnet: D (Built-in), Series: 85 (Standard), Head Cover Type: N (Basic Integrated Clevis), Bore Size: 25mm, Stroke: 50mm, Cushion: Rubber Cushion, Rod Boot: None, Mounting Bracket: None, Accessory: None, Auto Switch Mounting Type: B (Band), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: M (1m)
Mounting: A (Both Ends Tapped), Bore Size: 50mm, Thread: Rc, Full Stroke: 50mm, First Stroke: 20mm, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: M (1m)
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 50/45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket: Both
Magnet: D (Built-in), Mounting: L (Foot), Bore Size: 20mm, Stroke: 50mm, Rod End Thread: Male Thread, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: M (1m), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Auto Switch Mounting Bracket)
Magnet: D (Built-in), Mounting: B (Basic Style), Style: Aluminum Tube, Bore Size: 40mm, Thread: TN (NPT), Stroke: 50mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewied Connector: M (1m)
Mounting: A (Both Ends Tapped), Bore Size: 50mm, Thread: Rc, Full Stroke: 50mm, First Stroke: 45mm, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: M (1m)
Magnet: Built-in, Mounting: Double Clevis, Bore Size: 63mm, Port Thread Type: G, Stroke: 50mm, Body Option: Rod End Female Threads, Standard, Locking Direction: Extension Locking, By-Pass Piping: None (Emergency Stop), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 1m, Number: -
Magnet: Built-in, Mounting: Basic Style, Style: Aluminum Tube, Bore Size: 40mm, Thread: NPT, Stroke: 50mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Air Pressure Lock-up, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewied Connector: 1m, Number: -