CXSJM15 CXSJM20 CXSJM25 CXSJM32 CXSJL15 CXSJL20 CXSJL25 CXSJL32 CXSM15-PS CXSM20-PS CXSM25-PS Items !7, !8, and !
CXSJM15 CXSJM20 CXSJM25 CXSJM32 CXSJL15 CXSJL20 CXSJL25 CXSJL32 CXSM15-PS CXSM20-PS CXSM25-PS Items !7, !8, and !9 from the chart above CXSM32-PS CXSL15APS CXSL20APS CXSL25APS CXSL32APS 8 Series CXSJ Construction: Axial Piping CXSJ6P, CXSJ10P e q t w r u y i o Parts List: Axial Piping No.
CXSJM15 CXSJM20 CXSJM25 CXSJM32 CXSJL15 CXSJL20 CXSJL25 CXSJL32 CXSM15-PS CXSM20-PS CXSM25-PS Items !7, !8, and !9 from the chart above CXSM32-PS CXSL15APS CXSL20APS CXSL25APS CXSL32APS 8 Series CXSJ Construction: Axial Piping CXSJ6P, CXSJ10P e q t w r u y i o Parts List: Axial Piping No.
Dual rod cylinder with air cushion, Slide bearing or ball bushing bearing, Bore sizes: 20mm, 25mm, 32mm, Standard strokes: 20-100mm, Thread types: M, Rc, NPT, G, Auto switches available, FRONT PLATE (CXSM15), ACTUATOR, CXS GUIDED CYLINDER, G1, 15MM CXS PART, .04972 lb, SeriesDescriptionModelTypeNoteVol. no. (for std model)CXSDual rod cylinderCXSStandard type--3 From P. 561
Type Model Features Electrical entry Applicable bore size D-Z73, Z76 Grommet (In-line) Reed auto switch Without indicator light D-Z80 D-Y59A, Y59B, Y7P 25 to 63 Diagnostic indication (2-color display) D-Y7NW, Y7PW, Y7BW Solid state auto switch Grommet (In-line) Water resistant (2-color display) D-Y7BA With pre-wired connector is also available in solid state auto switches.
90 102 102 143 153 50 st or less 5.5 0 4 0 9.5 5 Over 50 st 42.5 36 46 41 68.5 69 Bore size (mm) 32 40 50 63 80 100 32 40 50 63 80 100 71.5 71.5 81 81 93 105 20 20 25 25 28 36 24 17.5 25 20 18.5 21 16 16 20 20 25 30 Grooves (Except 12, 16, 20, 25) (mm) Use grooves section a and section b in the figure below of the cylinder body for firmly fixing in the following case.
(When the allowable interval is specified for each cylinder series, use the indicated value.) 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (D-A6, A80, A80H, A90, A90V, C80, R80, 90, E80A, Z80).
As a rule, it should be turned about 90 past the position at which tightening can be felt. 8-24-8 9 Series MGT Specific Product Precautions Be sure to read before handing. Mounting Mounting Warning Caution 1. Do not put hands or fingers between the plate and body.
MY1CW MY1MW m 200 200 190 (kg) (kg) 190 (2100) (2100) (2100) (2100) 180 180 l 170 170 160 160 150 150 140 140 m l (2400) (2400) (2400) (2400) (2400) (2400) 130 130 (1800) (1800) (1800) (1800) m 120 120 Weight (m) Weight (m) 110 110 MY1MW63 MY1MW63 MY1MW63 100 100 (2000) (2000) (2000) (2000) (2000) (2000) l l 90 90 (1500) (1500) (1500) (1500) MY1CW63 MY1CW63 80 80 MY1MW50 MY1MW50 MY1MW50 Caution
90 108 108 20 20 25 30 30 32 40 50 2 2 3 3 M18 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 M8 x 1.25 depth 16 Up to 300 Up to 300 Up to 300 35 40 40 32 37 37 M10 x 1.5 depth 16 M10 x 1.5 depth 22 M12 x 1.75 depth 22 Note) < >: Denotes the dimensions for G port.
1 Smooth Cylinder CQSY/CQ2Y/CM2Y/CG1Y/CA2Y 12 to 25 32 to 100 20 to 40 20 to 100 40 to 100 RE A B Minimum 0.01 to 0.03 MPa operating pressure Minimum Minimum 0.01 to 0.03 MPa operating pressure REC CX 0.04 Minimum operating pressure MPa CY 12 16 0.03 MQQ M 20 25 32 40 0.02 RHC 50 63 80 100 0.01 MK(2) 0 0 10 20 30 40 60 50 70 80 90 100 RS Q G Bore size mm RS H A (Measurement based on JIS B8377
Lead wire length (m) Load voltage Auto switch model Tie-rod mounting Band mounting Indicator light Wiring (Output) Pre-wire connector Special function Type Electrical entry Applicable load 0.5 (Nil) 3 (L) 5 (Z) AC DC 3-wire (NPN equivalent) Z76 5 V IC circuit Grommet B53 B54 A33 A34 A44 B59W G59 G5P K59 G39 K39 G59W G5PW K59W G5BA G59F Z73 A54 A33C A34C A44C A59W Y59A Y7P J51 Y59B G39C
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 20 25 32 40 0.02 RHC 50 63 80 100 0.01 MK(2) 0 0 10 20 30 40 60 50 70 80 90 100 RS Q G Bore size mm RS H A (Measurement based on JIS B8377) RZQ MI W S CEP1 Stable operation possible even at a low speed of 5 mm/s (Measurement based on JIS B 8377) Sliding
Supply voltage Internal voltage drop of switch Minimum operating voltage of load _ > 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (Model D-A6l, A80, A80H, A90, A90V, C80, R80, 90, E80A, Z80).
D-Z73 D-Y59B D-Y59A Load voltage 24 VDC,100 VAC 24 VDC (10 to 28 VDC) 28 VDC or less Load current range Indicator light Application Relay, PLC 24 VDC Relay, PLC IC circuit, Relay, PLC 5 to 40 mA, 5 to 20 mA 5 to 40 mA 40 mA or less PLC: Programmable Logic Controller Refer to page 889 for the applicable auto switch list.
Allowable load mass mv (kg) Maximum operating pressure Pv (MPa) Cushion Stroke Model Stroke (mm) 25 30 1 5 0.3 Model CYP15 CYP32 CYP15 CYP32 8-17-6 6 Clean Room Rodless Cylinder Series CYP 15, 32 How to Order MX CYP 15 Z73 200 MTS MY Number of auto switches Nil S n 2 pcs. 1 pc. n pcs.
Series 10-MGF Guide table 40, 63, 100 How to Order 10 M G F 63 50 Y59B Number of auto switches 2 pcs. 1 pc. 10 Clean series Relief type Nil S Bore size (mm) Reed switch Type of auto switch Port type Z73 Solid state switch Y59A,Y59B Bore size Type Rc NPT G Symbol Nil TN TF 40, 63, 100 Cylinder stroke (mm) Model Cushion Bore size (mm) 40 63 100 Standard stroke (mm) Auto switch mounting Action
Provides high linearity and high precision. 1 Series CYP How to Order CYP 15 Z73 200 Clean rodless cylinder Cylinder bore size Number of auto switches 15 32 15mm 32mm 2 pcs. 1 pc. n pcs. Nil S n Standard stroke Standard stroke (mm) 100, 150, 200, 250, 300 350, 400, 450, 500, 600, 700 Bore size (mm) Type of auto switch 15, 32 Nil Select auto switches from the table below.
As a guide, it should be turned about 90 past the point at which tightening can be felt. 15 mm or more Iron plate, etc. Slotted set screw (M2.5 x 4l) (Included as accessory) Flat head watchmakers screwdriver Auto switch Other than the applicable auto switches listed in How to Order, the following auto switches can be mounted. For detailed specifications, refer to page 8-30-1.
As a guide, it should be turned about 90 past the point at which tightening Tighten M2.5 screws with a torque of about 0.5 to 0.7 Nm, and M3 screws with a torque of about 0.5 to 0.7 Nm Inserting Direction for Mounting Auto switches can only be inserted from the head side. Inserting Direction for Mounting Auto switches can only be inserted from the head side.