-40D 160 50 MHY Pressure 0.7 MPa Pressure 0.7 MPa 140 0.6 0.6 40 Gripping force (N) Gripping force (N) 120 MHW 0.5 0.5 100 30 0.4 0.4 80 MRHQ 0.3 0.3 20 60 0.2 0.2 Misc. 40 10 20 D0 20 40 60 Gripping point L (mm) 100 80 20 40 60 Gripping point L (mm) 80 100 120 140 160 0 20Confirmation of Gripping Point MHY Step 2 MHW 200 60 H H 50 Overhang H (mm) Overhang H (mm) MHW2-20D 150 MHW2-25D MHW2
74 94 09 11 14 09.5 16.0 15.0 M8 x 1.25 M10 x 1.5 PA PG 7 8 9 Bore size (mm) 25 32 40 P Rc 1/8 Rc 1/8 Rc 1/4 SS 5.1 4.0 9.0 PB 112 134 150 PP1 12.7 15.5 17.5 PP2 12.7 18.5 20 Q 206 264 322 QQ 16 16 26 QW 46 60 72 RR1 18.9 22.0 RR2 17.9 24.0 TT 15.5 21.0 26.0 UU 16 16 21 VV 16 19 23 W 122 144 160 WW 11 13 20 YW 070 088 104 Z 240 300 360 60 80 100 25.50 29 .0 Hole sizes for centralized piping
MHS Applicable Tubing MHC Description/Model Nylon tubing T0425 4 1.0 13 20 to 60 Nylon12 Polyurethane tubing TU0425 4 0.5 10 20 to 60 Polyurethane Polyurethane coil tubing TCU0425B-1 4 0.5 20 to 60 Polyurethane Soft nylon tubing TS0425 4 0.8 12 20 to 60 Nylon12 Specifications MHT Outside diameter mm Max. operating pressure MPa Min. bending radius mm Operating temperature C Material MHY MHW
MHS Applicable Tubing MHC Description/Model Nylon tubing T0425 4 1.0 13 20 to 60 Nylon12 Polyurethane tubing TU0425 4 0.5 10 20 to 60 Polyurethane Polyurethane coil tubing TCU0425B-1 4 0.5 20 to 60 Polyurethane Soft nylon tubing TS0425 4 0.8 12 20 to 60 Nylon12 Specifications MHT Outside diameter mm Max. operating pressure MPa Min. bending radius mm Operating temperature C Material MHY MHW
42 22 21 150.5 8 M8 x 1.25 25 to 800 25 to 650 50 35 12 13 10 59 40 27 11 27 21 52 20 10 17 9 32 80.5 70 46 24 28.5 162.5 11 M8 x 1.25 25 to 800 25 to 650 60 35 15 18 10 67 40 26 27 23 64 20 13 17 9 32 98.5 85 48.5 24 28.5 174 11 M10 x 1.25 13.5 25 to 750 25 to 600 70 40 17 23 14 72 52 30 32 23 78 25 15 21 11 37 117.5 102 55 26.5 36 189 13 M12 x 1.75 16.5 25 to 750 25 to 600 80 40 19 25
Lead wire length(m)* Auto switch model Lead wire entry Perpendicular In-line Load voltage Special function Indicator light Electrical entry Wiring (Output) Applicable load Model 0.5 (-) 3 (L) 5 (Z) DC AC P P Z76 3 wire 5V IC Grommet Yes Reed switch P P P Z73 100V 24V 12V Relay PLC 2 wire 5V 12V P P Z80 No 100V IC 3 wire (NPN) 5V 12V P P Y59A Y69A p IC 3 wire (PNP) 5V 12V Y7PV Y7P P P p 2
NDH10 125 140 160 I-12 I-14 I-16 0.1 0.3 25 32 +0.084 0 2033 27 46 54 100 M30 x 1.5 E1 0.1 0.3 28 36 +0.084 0 39 30 48 54 105 M30 x 1.5 NX 0.1 0.3 32 40 +0.100 0 Data 39 34 55 60 110 M36 x 1.5 L1 U1 RR1 Rod End Nut Material: Rolled steel 30 d Applicable bore size (mm) d H B C D Part no.
(Refer to page 5 for detailed specifications of the contact protection boxes.) 6.2 5.7 3.4 12.5 Most sensitive position 8 Solid State Auto Switches/Direct Mount Type D-Y59 /D-Y69 /D-Y7P (V) A B A B Auto Switch Specifications D-Y5, D-Y6, D-Y7P, D-Y7PV (with indicator light) D-Y7PV D-Y59B D-Y59A D-Y69A D-Y7P D-Y69B Auto switch part no.
(Refer to page 5 for detailed specifications of the contact protection boxes.) 6.2 5.7 3.4 12.5 Most sensitive position 11 Series CYP Clean Room Rodless Cylinder Solid State Auto Switches/Direct Mount Type D-Y59 /D-Y69 /D-Y7P (V) A B A B Auto Switch Specifications D-Y5, D-Y6, D-Y7P, D-Y7PV (with indicator light) D-Y7PV D-Y59B D-Y59A D-Y69A D-Y7P D-Y69B Auto switch part no.
(Refer to page 5 for detailed specifications of the contact protection boxes.) 6.2 5.7 3.4 12.5 Most sensitive position 11 Series CYP Clean Room Rodless Cylinder Solid State Auto Switches/Direct Mount Type D-Y59 /D-Y69 /D-Y7P (V) A B A B Auto Switch Specifications D-Y5, D-Y6, D-Y7P, D-Y7PV (with indicator light) D-Y7PV D-Y59B D-Y59A D-Y69A D-Y7P D-Y69B Auto switch part no.
(mm) ML2B ML2B D-Z7/Z80 D-Y59/Y69 D-Y7P/Y7PV D-Y7W D-Y7WV A B Auto switch model Bore size (mm) 25 32 40 91 102.5 126.5 131.5 180 206 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.
115 74 48 17 135 20 46 M45 x 1.5 260 50 71 67 140 86 60 20 160 25 56 M56 x 2.0 285 60 71 67 140 86 60 20 160 25 56 M56 x 2.0 296.5 60 80 76 140 96 60 20 175 30 65 M64 x 2.0 325 70 ZZ + Stroke 80 76 140 96 60 20 175 30 65 M64 x 2.0 325 70 1728 Made to Order Common Specifications: -XB6: Heat Resistant Cylinder (10 to 150C) Symbol -XB6 Heat Resistant Cylinder (10 to 150C) 2 Air cylinder which
Calculation: (Example) CLJ2L16-60 Basic weight320 (16) Additional weight6.5/15 stroke Cylinder stroke60 stroke 320 + 6.5/15 x 60 + 27 = 373 g 4 4.4 5 3 2 1 Stopping Accuracy (Not including tolerance of control system.)
Bore size mm (in) Bore size Operating range Operating range l (mm) 180 200 15 (0.6) 15 (0.6) 9 Series CQ2 Compact Cylinder Solid State Auto Switches/Direct Mounting Type D-Y59 , D-Y69 , D-Y7P (V) A B A B Auto Switch Specifications D-Y5, D-Y6, D-Y7P, D-Y7PV (with indicator light) D-Y7PV D-Y59B D-Y59A D-Y69A D-Y7P D-Y69B Auto switch model no.
Calculation: (Example) CLJ2L16-60 Basic weight320 (16) Additional weight6.5/15 stroke Cylinder stroke60 stroke 320 + 6.5/15 x 60 + 27 = 373 g 4 4.4 5 3 2 1 Stopping Accuracy (Not including tolerance of control system.)
30 60 80 40 80 100 50 100 120 70 120 160 100 160 200 60 10 40 MHC 60 MHT 16 40 MHY 60 MHW 20 40 MRHQ 60 25 Misc. 40 30 D32 20 2030 40 P . 12-4-7 20 Note) The open and close time spans represent the value when the exterior of the workpiece is being held.
32 5 20 45 16 40 CA2 80 90 95 11 11 16 10 72 94 50 36 5 20 45 16 50 CS1 100 110 60 115 12 11 20 10 55 20 89 41 5 25 113 60 C76 Mounting style (E) C85 C95 CP95 NCM NCA D-X 20Bore size (mm) d2 CK S5 K1 K2 l3 G1 l1 G2 EM G3 CA H6 R1 Data 32 11 10 38 51 10 21 18 26 31 32 10 6.6 7 8 40 11 12 41 54 10 24 22 28 35 36 11 6.6 9 10 50 15 12 50 65 12 33 30 32 45 45 12 9 11 12 63 15 16 52 67 14 37 35
6.6 9 10 50 15 12 50 65 12 33 30 32 45 45 12 9 11 12 63 15 16 52 67 14 37 35 40 50 50 15 9 11 12 80 18 16 66 86 18 47 40 50 60 63 15 11 12.5 14 100 18 20 11 76 96 20 55 13.5 50 60 70 71 15 19 Mounting style (CR): Head side clevis with ball joint A B C D EN ER F E L M N P H Bore size (mm) 0.2 max 0.2 H7 0.1 max H11 H13 H13 0.5 0.5 32 22 10 14 15 30 5 32.5 10.5 6.6 45 10.5 5.5 40 38 12 25
(Onty auto SWItch mounting bracket ISassembled at the lime of shipment) 2 Air Cylinder Series CS2 Specifications " Bore size (mm) 125 f 140 :1 1 60 . j Action Double actmg.