SMC Corporation of America
Elite Part Number Search
Search Results "CY1L10H-200-A80"

Cylinder: DP (Auto Switch/Plate Mount), Model: N (Non-lube), Bore Size: 15mm, Port Thread: Rc (M ø10, ø15), Stroke: 200mm, Cushion: 2 Adjuster Bolts, Auto Switch: A80--Reed, DC Volt.>5,<24, AC Volt.<100, Lead Wire, Vertical

Bore Size: 10mm, Port Thread: Rc, Magnetic Holding Force: Large Holding Force, Stroke: 200mm, Adjuster: Adjuster Bolt, Auto Switch: A80--Reed, DC Volt.>5,<24, AC Volt.<100, Lead Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -

Cylinder: Auto Switch/Plate Mount, Model: Non-lube, Bore Size: 15mm, Port Thread: Rc (M ø10, ø15), Stroke: 200mm, Cushion: 2 Adjuster Bolts, Auto Switch: A80--Reed, DC Volt.>5,<24, AC Volt.<100, Lead Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -

Cylinder: w/Auto Switch/Plate Mount, Model: Non-lube, Bore Size: 1 Inch, Stroke: 2 Inch, Cushion: Two Adjuster Bolts, Auto Switch: A80--Reed, DC Volt.>5,<24, AC Volt.<100, Lead Wire, Vertical, 0.5M, Number: -

Cylinder: w/Auto Switch/Plate Mount, Model: Non-lube, Bore Size: 3/8 Inch, Stroke: 2 Inch, Cushion: Two Adjuster Bolts, Auto Switch: A80--Reed, DC Volt.>5,<24, AC Volt.<100, Lead Wire, Vertical, 0.5M, Number: -

Cylinder: w/Auto Switch/Housing Mount, Model: Non-lube, Bore Size: 5/8 Inch, Stroke: 2 Inch, Cushion: Two Adjuster Bolts, Auto Switch: A80--Reed, DC Volt.>5,<24, AC Volt.<100, Lead Wire, Vertical, 0.5M, Number: -

Cylinder: w/Auto Switch/Housing Mount, Model: Non-lube, Bore Size: 1 Inch, Stroke: 2 Inch, Cushion: Two Adjuster Bolts, Auto Switch: A80--Reed, DC Volt.>5,<24, AC Volt.<100, Lead Wire, Vertical, 0.5M, Number: -

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, EE, 10MM CY1H/CY1L DBL-ACT A/S, 2.88307 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)10CY1L10H2.70.55

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, EE, 10MM CY1H/CY1L DBL-ACT A/S, 3.00562 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)10CY1L10H2.70.55

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 25mm, Stroke: 10mm, Action: S (Single Acting, Spring Return), Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: A80--Reed, DC Volt.>5,<24, AC Volt.<100, Lead Wire, Vertical, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc

Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Bore Size: 25mm, Stroke: 10mm, Action: T (Single Acting, Spring Extend), Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: A80--Reed, DC Volt.>5,<24, AC Volt.<100, Lead Wire, Vertical

Magnet: D (Built-in), Bore Size: 10 (3/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0600 (6 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: A80--Reed, DC Volt.>5,<24, AC Volt.<100, Lead Wire, Vertical, 0.5M

Magnet: D (Built-in), Bore Size: 15 (5/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0300 (3 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: A80--Reed, DC Volt.>5,<24, AC Volt.<100, Lead Wire, Vertical, 0.5M

Magnet: D (Built-in), Bore Size: 15 (5/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0600 (6 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: A80--Reed, DC Volt.>5,<24, AC Volt.<100, Lead Wire, Vertical, 0.5M

Magnet: D (Built-in), Bore Size: 15 (5/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 1000 (10 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: A80--Reed, DC Volt.>5,<24, AC Volt.<100, Lead Wire, Vertical, 0.5M

Magnet: D (Built-in), Bore Size: 15 (5/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 1200 (12 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: A80--Reed, DC Volt.>5,<24, AC Volt.<100, Lead Wire, Vertical, 0.5M, Number: 3 pcs.

Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 1200 (12 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: A80--Reed, DC Volt.>5,<24, AC Volt.<100, Lead Wire, Vertical, 0.5M

Magnet: D (Built-in), Bore Size: 40 (1 1/2 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 2500 (25 Inch), Adjuster: Adjuster Bolt, Auto Switch: A80--Reed, DC Volt.>5,<24, AC Volt.<100, Lead Wire, Vertical, 0.5M, Number: S (1 pc.)

Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0500 (5 Inch), Adjuster: Adjuster Bolt, Auto Switch: A80--Reed, DC Volt.>5,<24, AC Volt.<100, Lead Wire, Vertical, 0.5M

Magnet: Built-in, Mounting: Basic, Bore: 10mm, Stroke: 15mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A80--Reed, DC Volt.>5,<24, AC Volt.<100, Vertical, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Rail Mounting, Cushion: -, Series: -