SMC Corporation of America
Elite Part Number Search
Search Results "CY3R15-350-M9B"

Piping: Standard, Bore Size: 15mm, Port Thread: (M5 Thread-6~15mm)(Rc-20~63mm), Stroke: 50mm, Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: -, Number: -

, Auto Switches: M9B, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: N/A, Pivot Bracket: Without bracket, Rod End Bracket: Without bracket, Type of Mount Support: Rod-end flange type, Rod Boot: None, Custom-made Specifications: None, Stroke adjustment symbol: -

: Built-in magnet, Port thread type: Rc, Auto Switches: M9B, Lead Wire Length(m): 5, The number of the switches: 3, Type of Auto Switch Mounting: Standard, Type of Mount Support: Rod-end flange type, Rod Boot: None, Custom-made Specifications: None, Locking Direction: Bidirectional

: Built-in magnet, Port thread type: Rc, Auto Switches: M9B, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Type of Mount Support: Axial foot type, Rod Boot: None, Custom-made Specifications: None, Locking Direction: Bidirectional

cushions on both sides, Operating Pressure(MPa): -, Specification: -, Support bracket: Basic type, Port thread type: Rc, Auto Switches: M9B, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: APC, Rod Boot: Without rod boot, Tube Material: Aluminum tube, Custom-made Specifications: None, Locking Direction: Bidirectional

Auto Switches: M9B, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Lock Position: With head-end lock, Type of Mount Support: Rod-end flange type, Rod Boot: None, Custom-made Specifications: None, Lock actuation system: Non-locking type

thread type: Rc, Auto Switches: M9B, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Rod End Bracket: None, Type of Mount Support: Rod-end flange type, Rod Boot: None, Custom-made Specifications: None, Customized specification (port positions): -, Type: Lube type, Stroke adjustment symbol: -

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: M9B, Lead Wire Length

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: M9B, Lead Wire Length(m): 3, The number

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: M9B, Lead Wire Length(m): 3, The number

Load voltage AC DC Auto switch model Lead wire length (m) Indicator light Pre-wire connector Special function Type Electrical entry Wiring (Output) Applicable load 0.5 (Nil) 3 (L) 5 (Z) Perpendicular In-line 3-wire (NPN equivalent) IC circuit A96V A96 5 V Reed switch Solid state switch Yes Yes Grommet 100 V 24 V 12 V A93 M9N M9P M9B F9NW F9PW F9BW A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches