Mounting of auto switch Auto switch mounting screw (M2.5 x 0.45 x 8L) Tightening Torque of Auto Switch Mounting Screw [Nm] Auto switch Auto switch model Tightening torque Auto switch mounting nut D-M9(V) D-M9W(V) D-M9A(V) D-A93 Auto switch mounting screw (M3 x 0.5 x 8L) 0.05 to 0.15 Auto switch D-A9(V) (Excluding D-A93) 0.10 to 0.20 Auto switch fixing screw (M2.5 x 0.45 x 10L) Auto switch
However, if there is any problem, use a 3 wire DC style. 3.8-11 Series CXT Auto Switch Mounting Position and Mounting Height Reed switch Solid state switch A B W D-F9NW D-F9PW D-F9BW D-A90 D-A93 D-A96 D-F9N D-F9P D-F9B D-F9BAL 12 A B W 16, 20, 25 W A B 32, 40 (mm) D-A90 D-A93 D-A96 D-F9NW D-F9PW D-F9BW D-F9N D-F9P D-F9B Auto switch model D-F9BAL Symbol A B W A B W A B W Standard stroke 12
Consult with SMC regarding water resistant types with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. DLead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ For details about auto switches with pre-wired connector, refer to pages 1648 and 1649.
Standard stroke 12 16 20 25 How to Order . 1 5, 10, 15, 20, 25, 30 5, 10, 15, 20 25, 30, 35, 40, 45, 50 Note 1) Single Rod Double Rod Return/Extend Single Rod Accessories . 5 Long stroke 12 16 20 Double Acting Single Acting Double Acting 35, 40, 45, 50, 75, 100 75, 100, 125, 150 175, 200 75, 100, 125, 150 175, 200, 250, 300 Construction . 6 25 Dimensions . 7 & 8 Reed switch D-A90, A90V D-A93
Lead wire length symbols: 0.5 mNil (Example) A93 3 mL (Example) Y59BL 5 mZ (Example) F9NWZ Refer to page 8-12-24 for details on other applicable auto switches than listed above.
Lead wire length (m) Load voltage 5 (Z) Applicable load Auto switch model Electrical entry direction Wiring (Output) Special function Electrical entry Indicator light Type 0.5 (Nil) 1 (M) 3 (L) AC DC 12 V In-line A93 M9N M9B Reed auto switch 24 V 2-wire 100 V 12 V Relay, PLC Grommet Yes 3-wire (NPN) Solid state auto switch 24 V Relay, PLC Grommet Yes 12 V 2-wire Lead wire length symbols
(mm) D-A90V D-A96V D-A93V 22 Bore size D-M9V D-F9WV D-M9 D-F9W D-A90 D-A96 D-A93 (mm) 32 20 32 Mounting pattern q, w 35 Mounting pattern e 20 12 Mounting of Auto Switch As shown below, there are 3 ways to mount the auto switch according to 3 types of electrical entries. Insert the auto switch into the switch groove.
A93 3m . L (Ex.) A93L 5m . Z (Ex.) F9NWZ Solid state auto switches marked with a "" are produced upon receipt of order.
Operating temperature range (C) 5 to 60 Standard Strokes Bore sizes (mm) Standard strokes (mm) Max. manufacturable stroke (mm) 16 100, 200, 300, 400, 500, 600, 700 800, 900, 1000, 1200, 1400, 1600 1800, 2000 3000 20, 25, 32, 40, 50, 63 Strokes can be manufactured in 1mm increments, up to the maximum stroke.
Nil (Example) A93 3m .
MY2 H/HT MY3A MY3B m (800) MY3M 50 L (600) 40 m L 30 MY1H40 (550) Mass m (kg) m MY1H32 20 L L MY1H25 10 Caution 1. If the cylinder mounting surfaces are not measured accurately, using a side support may cause poor operation. Therefore, be sure to level the cylinder tube when mounting it.
Separate switch spacers (BMG2-012) are required to retrofit auto switches (M9 type) on cylinders 25 to 63. 2 1 m type lead wire is only applicable to D-A93. Refer to page 1360 for details on other applicable auto switches than listed above. For details about auto switches with pre-wired connector, refer to pages 1648 and 1649. Auto switches are shipped together (not assembled).
: Built-in magnet, Port thread type: Rc, Auto Switches: A93, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Type of Mount Support: Axial foot type, Rod Boot: None, Custom-made Specifications: None, Locking Direction: Bidirectional
Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.08~0.97, Cushion: With
Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.08~0.97, Cushion: With
, Auto Switches: A93, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Lock Position: With rod-end lock, Type of Mount Support: Head-end flange, Rod Boot: None, Custom-made Specifications: None, Lock actuation system: Non-locking type
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches