/25 CY1H15/20/25 CY1H15/20/25 CY1H15/20 CY1H15/20 CY1H25 CY1H15/20 CY1H25 0.08 0.03 CY1H25 Deflection (mm) Deflection (mm) Deflection (mm) Deflection (mm) 0.02 0.06 0.02 0.04 0.01 0.01 0.02 25 25 25 5 10 15 20 0 Moment (Nm) 5 10 15 20 0 Moment (Nm) 5 10 15 20 0 Moment (Nm) CY1HT25/32 CY1HT25/32 CY1HT25/32 0.05 CY1HT25 CY1HT25 CY1HT32 CY1HT25 CY1HT32 0.03 Deflection (mm) Deflection (mm) 0.04
at the time of shipment, and should be operated at the full stroke.
to 500 20 to 600 20 to 600 20 to 750 20 to 750 30 to 1000 30 to 1000 30 to 1200 27 32 32 37 37 47 47 53 60 70 86 102 116 145 161 182 22 27 27 32 41 59 67 73 77 85 112.5 121 133 69 78 84 92 100 141.5 150 167 44 52 64 78 92 115 128 144 10 12 16 20 25 25 28 32 17 17 20 16 20 20 25 30 36 36 40 40 50 55 65 80 90 90 90 6.5 6.0 6.0 8.0 8.0 43 43 43 14 14 14 15 17 17 21 21 16 16 18.5 15 17 17 21
n +4 0 R ra g n 0 n io at ot ra R 18 R n ot io ve R at at oo io ot ot R n gr ra y ng at ke e of +4 0 io n 0 ra 19 ng e e ov of o ke gr y Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Switch A Switch B Proper Auto Switch Mounting Position at Rotation End CDRA1W30
Keep the upstream pressure at a certain constant level above 0.3MPa. First measure the maximum flow rate in saturation. Then, measure the flow rate, upstream pressure and downstream pressure each at 80%, 60%, 40% and 20% points of the flow rate. Calculate the sonic conductance C from the maximum flow rate.
K Non-rotating Symbol Stroke ZP2A-002 10 20 30 40 50 B5 10 mm 20 mm 30 mm 40 mm 50 mm M5 x 0.8 Buffer Specifications 4 onetouch fitting 04 6 onetouch fitting Stroke (mm) 10, 20, 30, 40, 50 1.0 3.0 3.0 Nm 5% 06 ZP2A-003 At 0 stroke (N) At buffer stroke (N) Spring reactive force Note 1) in the table indicates the pad material. Note 2) in the table indicates the buffer stroke.
Fixed end Burst pressure (MPa) Min. bending radius (mm) Note) 10 15 20 27 35 Air: 20 to 60C, Water: 0 to 40C (No freezing) Operating temperature Polyurethane Material Note) The minimum bending radius indicates the value at which the tubing will fold at a temperature of 20C. At a higher temperature, the tubing may fold at more than the minimum bending radius.
Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Note 4) Based on JIS C 0920.
200 to 230V (4 cores x 8 mm2) R8-5 AC(60Hz) including HRL300-A-20 50 ground 1 Cable specifications are the examples when using the product at a continuous allowable operating temperature of 70 oC, with an operating voltage of 600 V and two kinds of plastic insulated wires at an ambient temperature of 30 oC.
Magnetic Holding Force (N) 63 50 40 32 25 20 15 10 6 Bore size (mm) Holding force (at 150C) 1590 1000 641 410 250 160 90.1 40.0 14.4 Holding force (at 100C) 1900 1190 766 490 299 192 107 47.9 17.2 Temperature Range for Operating Cylinder and Piston Speed (mm/s) 400 Standard model no.
Grease should be applied at 1 million cycles or 200 km, whichever comes first. LEC Y Motorless Motorless Grease pack order number: GR-S-010 (10 g)/GR-S-020 (20 g) LAT LZ LC3F2 885
As the circulating fluid temperature at this time is 20 oC, "AS.06" starts alarm monitoring at the same time as the operation start. Status (2): The circulating fluid temperature becomes within the set range of "AS.04", and starts "AS.04" alarm monitoring".
C85LlA 20 40 95 Foot (2 pcs. with 1 mounting nut) C85LlB 55 105 210 Mounting bracket Flange C85Fl 12 25 90 Calculation example: C85KN20-50NV O Basic weight189 g (20) O Additional weight8.7 g (at 10 mm stroke) O Cylinder stroke50 mm O Mounting bracket: Clevis85 g O Accessory: Rod end45 g Trunnion C85Tl 20 50 75 Clevis C85Cl 20 40 85 Rod end KJlD 17 25 45 70 Double knuckle joint GKMl-l 10 20
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
Non-rotating Rod Accuracy (No load/At retraction of the rod at the locking plateside) Bore size (mm) 10 0.8 16 20 25 0.5 32 Non-rotating rod accuracy Allowable Rotational Torque Bore size (mm) 10 16 20 25 32 0.20 Allowable rotational torque (Nm) Minimum Operating Pressure 0.02 0.04 0.10 0.15 (MPa) Bore size (mm) 10 16 20 25 32 3.
at extension end Stroke adjuster at retraction end 37.5 (With stroke adjuster at extension end) 12 6 N x M5 x 0.8 thread depth 6 (Insert) 6 4 x M5 x 0.8 thread depth 7 1 (With stroke adjuster at extension end) 3.5 (With stroke adjuster at retraction end) 26 58 35 62 48 5H9 ( ) depth 4 +0.030 0 F 20 18 N 1 x F 2 2 x M6 x 1 thread depth 10 41 +0.030 0 5H9 ( ) depth 4 30 M 0.5 37.5 40 Z ZZ