Number of stations: 1 station, Option: With Bracket, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (Rc1/8), detection side (ø6 one-touch), Output specifications: NPN 1 output, Unit specification for pressure values: With unit switching function, Cable: Straight cable
Number of stations: 1 station, Option: No bracket, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (Rc1/8), detection side (ø6 one-touch), Output specifications: NPN 1 output, Unit specification for pressure values: With unit switching function, Cable: None
Number of stations: 2 stations, Option: With Bracket, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (Rc1/8), detection side (ø6 one-touch), Output specifications: NPN 1 output, Unit specification for pressure values: With unit switching function, Cable: Straight cable
Number of stations: 2 stations, Option: With Bracket, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (Rc1/8), detection side (ø6 one-touch), Output specifications: NPN 1 output, Unit specification for pressure values: With unit switching function, Cable: None
Number of stations: 2 stations, Option: With Bracket, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (Rc1/8), detection side (ø6 one-touch), Output specifications: NPN 1 output, Unit specification for pressure values: With unit switching function, Cable: Centralized lead wire
Number of stations: 1 station, Option: No bracket, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (Rc1/8), detection side (ø6 one-touch), Output specifications: NPN 1 output, Unit specification for pressure values: SI unit fixed, Cable: Straight cable
Number of stations: 1 station, Option: With Bracket, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (Rc1/8), detection side (ø6 one-touch), Output specifications: NPN 1 output, Unit specification for pressure values: SI unit fixed, Cable: Right-angle cable
Number of stations: 2 stations, Option: No bracket, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (Rc1/8), detection side (ø6 one-touch), Output specifications: NPN 1 output, Unit specification for pressure values: SI unit fixed, Cable: Straight cable
Number of stations: Triple, Option: No bracket, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (Rc1/8), detection side (ø6 one-touch), Output specifications: NPN 1 output, Unit specification for pressure values: SI unit fixed, Cable: Straight cable
The ISA series is a non-contact style air catch sensor for applications requiring confirmation of work present for machining operations. Due to the construction of the sensor, fluctuations in the supply pressure does not influence operations. The ISA series is IP66 rated and is dust proof and drip proof. Air catch sensor, Operating pressure: 0.05 to 0.2MPa, Enclosure IP66, Port size: 1/8
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 1, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: L2 (w/Control Unit, Supply Port:
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: N (NPN Output), Unit Specification: M (Fixed SI Unit), Stations: 1, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: L2 (w/Control Unit, Supply Port:
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 1, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: L4 (w/Control Unit, Supply Port:
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 1, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: L3 (w/Control Unit, Supply Port:
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: N (NPN Output), Unit Specification: M (Fixed SI Unit), Stations: 1, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: L3 (w/Control Unit, Supply Port:
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: B (PNP, 2 Outputs), Unit Specification: M (Fixed SI Unit), Stations: 1, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: L3 (w/Control Unit, Supply Port
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 1, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: R1 (w/Control Unit, Supply Port:
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 1, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: L6 (w/Control Unit, Supply Port:
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Unit Specification: M (Fixed SI Unit), Stations: 1, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: R1 (w/Control Unit, Supply Port: Right Side, With regulator, Round type
Rated Distance Range: F (0.01 to 0.03mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Unit Specification: M (Fixed SI Unit), Stations: 1, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: R4 (w/Control Unit, Supply Port: Right Side, With regulator, Square type pressure gauge, 0.2 MPa), 2 Port Solenoid Valve Rated Voltage: 2 (110 VAC)