Bore size (mm) NN P S X Y ZZ 20 M22 x 1.5 1/8 81 20 9 151 25 M24 x 1.5 1/8 81 20 9 156 32 M30 x 1.5 1/8 87 23 9 172 40 M33 x 2 1/4 108 25 11 198 49 Round Type Low Pressure Hydraulic Cylinder: 3.5MPa Series CHM Front flange type: CHMF Width across flats B2 Width across flats B1 N GA GB Rc P N Rc P 4-FD H1 H2 2-NN I IA D FY B MM Effective thread K F NB Width across flats NA NC FT A FX H S +
keeper plate mounting screw J P H A B C D d K L L1 E Part no.
Plug Part Number Bore size Part number Port thread type Quantity1 12 (10 x 2) 16 (12 x 2) P-M3 M3 8 20 (16 x 2) 25 (20 x 2) 32 (25 x 2) P-M5 M5 8 P-R1 Rc1/8 8 40 (32 x 2) 50 (40 x 2) 63 (45 x 2) P-N1 NPT1/8 8 P-G1 G1/8 8 P-R2 Rc1/4 8 80 (56 x 2) 100 (71 x 2) P-N2 NPT1/4 8 P-G2 G1/4 8 *1 1 set includes 8 pieces.
Visible Visible Air suction side Filter Filter holder LED Indicators PWR Power supply indicator ION/HV Static neutralization operation/ Incorrect high voltage indicator ALM Error indicator NDL Maintenance indicator 4 Fan Type Ionizer IZF Series Models and Functions New New IZF21 IZF31 IZF10 IZF10R P.11 P.11 P.21 P.21 Size (Depth x Width x Height) (mm) 40 x 104 x 155 40 x 144 x 195 39 x 80
In center position the flo/v P-A, B is as sholn. X X { l ) Series NVFSOO How To Order NVFs lPort size (P,A,B) OXT Y.NPIF O3T %NPTF o4T. _ IbNPIF Typ of I *2 positiqr/singlo solanoid 2 -e position/double eolgnoid l-3 posilion, dGd c6oter/doubl6 solonoid 4 -3 gooidofl extEugt centr/double solenoid 5 -A pEsilion, p.6sure crte./double solenoid oyeride 'Subbas type only.
P LED Table 10-28 P LED LED state Meaning OFF No safe communication Green ON Safe communication is running. Green Flash Safe communication is running. The controller is requesting operator acknowledgment 64 No.EX##-OMY0004 10.10.
SI No. 1 COM M OUT 1 COM 0V 2 3 P OUT 1 Zone 1 4 SOL 0 0 Zone 1 ON Zone 1 11 SOL 7 7 Zone 1 ON 12 P OUT 2 Zone 2 13 SOL 8 8 Zone 2 ON Zone 2 20 SOL 15 15 Zone 2 ON 21 P OUT 3 Zone 3 22 SOL 16 16 Zone 3 ON Zone 3 29 SOL 23 23 Zone 3 ON 30 N. C. N.
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: 01 (R1/8), Lead Wire: w/o Lead Wire, Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)]
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: 01 (R1/8), Lead Wire: w/o Lead Wire, Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)], Operation Manual: T (w/o Operation Manual, Calibration Certificate)
Note that the products used for the port size A2 or A3 are not available at SMC.
Specifications AC adapter (IZF21-CG1 / IZF21-CG2) Model Air flow Applied voltage Ion generating method Voltage application method IZF21 (NPN) IZF21-P (PNP) IZF31 (NPN) IZF31-P (PNP) 1.8 m3/min 4.4 m3/min +/-5kV Corona discharging method DC Offset voltage (ion balance) Note) +/-5 V 24 VDC +/-10 (%) Power supply voltage 0.9 A or less 1.3 A or less Current consumption Connect with +24 V Voltage
Service Class Inst Attr ID Values ID ID Reset 01 h [Identity Object] 1 h 01 (Type1 reset) -35No.EX-OMX1001
Colour on the feed holes Cable colour Signal Cable O.D. 4.0 to 8.0 mm Electric wire cross section (Twist line) AWG26 to 22 YE=Yellow or OGWH=Orange/ White 1 Orange/ White TD+ WH=White or GNWH=Green/ White 2 Green/ White RD+ 3 Orange OG=Orange TD4 Green BU=Blue or GN=Green RD-40No.EX-OMP0013-E (3) Cable with communication connector Part number: EX9-AC 01 0EN-PSRJ Cable length (L) 01 1000 [
PF-OMK0003CN-E PFMV505 PFMV510 PFMV530 PFMV505F PFMV510F PFMV530F N2 (JIS B8392-1 1.1.21.6.2ISO8573-1 1.1.21.6.2) 2 2 2 () 00.5 01 03 -0.50.5 -11 -33 1 L/min L/min L/min L/min L/min L/min 2F.S. 3 2F.S.(1535 ) (25) 5F.S.(050 ) 2F.S.(0300 kPa) 5F.S.(-700 kPa) (0kPa 4) -70300 kPa -100400 kPa 500 kPa 5 15 V 5 ms 1 k DC1224 V10(p-p) 10() 16 mA IP40 050 () 050 -1060 () 3585R.H
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: 01 (R 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A2 (Bracket B, Horizontal Mounting)
Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: 01 (R 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A2 (Bracket B, Horizontal Mounting)
Specifications Model ISE35 Rated pressure range 0 to 1 MPa Display/setting pressure range 0.1 to 1 MPa ZSE20 ISE20 Withstand pressure 1.5 MPa ZSE30 ISE30 Minimum display/setting unit 0.01 MPa Applicable fluid Air, Non-corrosive gas, Non-flammable gas ZSE40 ISE40 12 to 24 VDC 10%, Ripple (p-p) 10% or less (With power supply polarity protection) Power supply voltage ZSE10 ISE10 Current consumption
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting), Operation Manual: K (Operation Manual, Calibration Certificate)