L6 T Inch Size A1 A2 M1 T Model H d D1 L2 L5 L6 D3 D4 L1 D2 L4 L3 ASD230F-U10/32-01D 1/8" 8.4 12.9 29.4 17.5 ASD230F-U10/32-03D 5/32" 9.3 27.4 7.8 10-32 UNF 8 0.7 31 11.7 9.6 10 4.7 30.7 ASD230F-U10/32-05D 16.5 3/16" 11.4 35.2 23.3 ASD230F-U10/32-07D 13.5 1/4" 12 32.6 20.7 ASD330F-N01-05SD 16.5 3/16" 11.6 38.5 14 23.9 38.9 ASD330F-N01-07SD 31.6 10.6 NPT 1/8 12.7 17 35.6 1.2 7.2 14.2 11.8
-01ST AS221F-01-04ST 1/8" 8.4 4 20.4 27.5 9.3 5/32" 9.3 20.4 27.5 12.7 14.3 AS221F-N01-03ST AS221F-01-06ST 13.5 12 R 1/8 14.2 7 35.6 1.5 31.6 6 11.6 3/16" 11.4 23.1 30.2 14.3 16.5 AS221F-N01-05ST AS221F-01-08ST NPT 1/8 12.7 14.2 7 35.6 1.5 31.6 18.5 25.3 32.4 8 15.2 AS221F-N01-07ST AS221F-01-10ST 1/4" 13.2 23.9 31 18.5 15 21 33.1 40.2 10 18.5 AS221F-N01-09ST AS221F-02-04ST 15 5/16" 15.2 25.3
12 V Reed auto switch Solid state auto switch 12 V IC circuit Diagnostic indication (2-color indicator) 5 V, 12 V Relay, PLC Yes Grommet 24 V 12 V IC circuit 5 V, 12 V Water resistant (2-color indicator) M9PAV1 M9PA1 M9BAV1 M9BA1 12 V 3-wire (NPN equiv.)
Common Adjuster Options Model Stroke 10 20 30 40 50 75 100 125 150 MXQ6(L)-Zmm(6, 7, 8, 9) v v v v v MXQ8(L)-Zmm(6, 7, 8, 9) v v v v v v MXQ12(L)-Zmm(6, 7, 8, 9) v v v v v v v MXQ16-Zmm(6, 7, 8, 9) u v v v v v v v MXQ20-Zmm(6, 7, 8, 9) u v v v v v v v v MXQ25-Zmm(6, 7, 8, 9) v v v v v v v v v MXQ6A, 8A, 12A 10, 20 mm stroke Auto switch is not mountable End plate Adjustment block MXQ16(A)
Pulse train signal specifications (Open collector input and differential input are common) 5 s or more 24 V 21.6 V to 26.4 V 5 V 4.75 V to 5.25 V PP3s or less 5 s or more 3s or less 16 s or more 28 - 7.4 Parallel I/O signals (Pulse Input Type) (1) Input side (Pulse input type) Function Description Common terminal for the input signal power supply.
Effective area [mm2] Min. port size Release button dimensions L A2 M P Q O N Applicable tubing O.D.
teaching Acceleration/ Deceleration Acceleration/deceleration during movement V V V Set in units of 1 mm/s2 Select from 16-level Select from 16-level Pushing force Rate of force during pushing operation V V V Set in units of 1% Set in units of 1% Select from 3-level (weak, medium, strong) Step data setting (Excerpt) Trigger LV Target force during pushing operation V V Set in units of 1%
SMC 50 35 5 SMC 6 28 (R) P P K U K C S U O C H L S O H L 38 AV AU Panel cut Panel thickness: Max. 4 Panel cut Panel thickness: Max. 3 34 AF 40 15.4 x 5.4 AR Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com IR 8 x 6.5 79 13 45.5 VEX Atmosphere 106 G SET SET Pad side
How to Order S 2 B P H S4 200 LEY 63 A2 w y !0 i o e r t q u !1 !2 !3 !
Controller Set Up (P.34) and 14. Card Motor Controller Configuration software (P. 57) for instructions on how to setup. (6) Test operation Refer to section 10. Monitor and Test Mode of the Controller (P.41) and 14.5 Monitor/Test window (P. 68) for instructions on operating instruction of test operation 14 - 3.
CHN CHM Examples of D-A9(V), M9(V), M9W(V), M9A(V) models mounted on CHKD.
IC circuit A56 5 V Reed switch Solid state switch A53 12 V Grommet Yes Relay, PLC 24 V A54 2-wire 100 V, 200 V Diagnosis indication (2-color) A59 W F59 3-wire (NPN) 5 V, 12 V IC circuit F5P 24 V 3-wire (PNP) J59 12 V 2-wire J51 100 V, 200 V Relay, PLC Yes Grommet F59 W 3-wire (NPN) 5 V, 12 V IC circuit Diagnosis indication (2-color) F5PW 3-wire (PNP) J59 W 24 V 2-wire F5BA
IC circuit A56 5 V Reed switch Solid state switch A53 12 V Grommet Yes Relay, PLC 24 V A54 2-wire 100 V, 200 V Diagnosis indication (2-color) A59 W F59 3-wire (NPN) 5 V, 12 V IC circuit F5P 24 V 3-wire (PNP) J59 12 V 2-wire J51 100 V, 200 V Relay, PLC Yes Grommet F59 W 3-wire (NPN) 5 V, 12 V IC circuit Diagnosis indication (2-color) F5PW 3-wire (PNP) J59 W 24 V 2-wire F5BA
Load voltage Indicator light Lead wire length (m) AC DC Auto switch model Applicable load Pre-wire connector Special function Type Electrical entry Wiring (Output) 5(Z) 0.5(Nil) 3(L) Perpendicular In-line Reed switch Solid state switch IC circuit 3-wire (NPN equivalent) A96 A96 5 V Grommet Yes Relay, PLC 2-wire A93V A93 100 V 24 V 12 V M9NV M9N 3-wire (NPN) IC circuit 5 V, 12 V M9PV
D D t D t t c e c c e e u u s u s s d i d i d i g g g o o o n n n r r r P P P A A A 1 1 9 9 9 9 9 9 w w 9 w 9 9 m I m I n n 9 9 9 u d u d a a a r u r u o s o F s tr F i e tr i e 9 9 9 D r r D r r r e e e e v v s 1 d d s 1 1 d o o i i n g n g n n n n a a H H n P n P g g r r o o i i s s d d e e u u D D c c t t d A d A r r w w a a 12-11-1 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way,
Option symbol P High-Pressure Pump Mounted P HECR Applicable model HECR002-A5-P HECR004-A5-P HECR006-A5-P HECR008-A5-P HECR010-A2-P HECR008-W5-P HECR012-W2-P High-pressure pump mounted Possible to choose a high-pressure pump in accordance with users piping resistance.
9 Specifications p. 10 Flow Range p. 11 Analog Output p. 11 Pressure Loss p. 11 IN Side Straight Section and Accuracy p. 12 Internal Circuits and Wiring Examples p. 12 Construction: Parts in Contact with Fluid p. 13 Dimensions p. 13 3-Screen Display Digital Flow Monitor PFG300 Series How to Order p. 14 Specifications p. 15 Internal Circuits and Wiring Examples p. 16
IC circuit Reed switch Solid state switch A96 A96V 5 V Grommet Yes Relay, PLC A93 A93V 12 V 2-wire 24 V 100 V 3-wire (NPN) M9N M9NV 5 V, 12 V IC circuit 3-wire (PNP) M9P M9PV 2-wire M9B M9BV 12 V Relay, PLC 3-wire (NPN) F9NW F9NWV 5 V, 12 V 24 V IC circuit Grommet Yes Diagnostic indication (2-color) 3-wire (PNP) F9PW F9PWV F9BW F9BWV 12 V 2-wire Water resistant (2-color) F9BA Although it
Rated Vacuum Range: -101 to 0 kPa, Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting), Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)
.: ZS-46-A2) Measurement mode screen Item Default setting To obtain the operation manual about this product and control unit, please refer to the SMC website (URL http://www.smcworld.com) or contact SMC directly.