OUT port size Material D side U side 1 2 3 4 5 n Symbol 01 02 Port size 1/8 (6A) 1/4 (8A) Stations Body material C37 Symbol Nil H Seal material FKM FKM 02 : 10 2 stations : 10 stations Stainless steel All IN ports are 3/8. Refer to the "L" dimensions on page 6 regarding the maximum number of stations.
ZSE5-02-27L Two Output NPN Open Collector 30V, 80mA ZSE5-02-67L Two Output PNP Open Collector 80mA ISE5-02-26L None (Analog Output) 1~5V(5%F.S.)
Flow Rate and Sonic Conductance Model AS1002F-mA AS2002F-mA AS2052F-mA AS3002F-mA AS4002F-mA Tubing O.D.
OUT port size Material Symbol 01 02 Port size 1/8 (6A) 1/4 (8A) Stations D side U side 1 2 3 4 5 n Body material Brass Symbol D H Seal material FKM FKM 02 : 10 2 stations : 10 stations All IN ports are 3/8. Stainless steel Refer to the L dimensions on page 6 regarding the maximum number of stations.
Materials Thread type Symbol Nil A G H Manifold material Seal material NBR FKM NBR FKM Rc G NPT Nil F N Brass 1 D side 2 3 4 5 U side Stainless steel OUT port size Stations Series 20 Port size M5 1/8 (6A) 1/4 (8A) Symbol 02 : 10 2 stations : 10 stations 30 10 M5 01 02 Note) IN port sizes are as follows. 10: 1/8 (6A) 20: 1/4 (8A) 30: 3/8 (10A) How to Order Valves (for Manifold) VDW 2 3 5
Model Allowable Moment (Nm) Allowable dynamic moment Model Mounting orientation Load movement direction LTF6 200 Horizontal/Lateral Horizontal/Lateral Lateral Horizontal a Mep L1 (mm) Pitching 100 m a=1000 a=2000 a=3000 L1 30 20 10 0 Transfer load m (kg) L2 200 a=1000 a=2000 a=3000 Mer L2 (mm) Rolling Yawing 100 m L2 Mer 30 20 10 0 m Transfer load m (kg) 200 a=1000 a=2000 a=3000 L3 (mm) 100
VT 3 (R) 1 (P) Solenoid Specifications VP Power consumption Note 1) 0.35 W (Standard), 0.5 W (High voltage), 0.1 W (Holding) 3, 5, 6, 12, 24 VDC 10% of the rated voltage Equivalent to class B Rated coil voltage Allowable voltage fluctuation Note 2) VG Coil insulation type VP Note 1) With a light/surge voltage suppressor and power saving circuit, the light consumes a power equivalent to 2 mA
'-02 ~2 06 >6 (Application: Refer to ListO) i 08 ~8 U Flat type Material a With buffer 04 4 Pad type.
*1: To use the power of the device, the total load current must be 500 mA or less.
) 100 VAC 0.5 VA (5 mA) Power consumption 0.65 VA (5.9 mA) 110 VAC 0.55 VA (5 mA) (current value) 1.2 VA (6 mA) 200 VAC 1.0 VA (5 mA) 1.3 VA (5.9 mA) 220 VAC 1.1 VA (5 mA) L plug connector Grommet Grommet L plug connector With light/surge voltage suppressor L plug connector (With light/surge voltage suppressor) ( ) Electrical entry With light/surge voltage suppressor Vacuum Pressure Switch
N L1 L2 L3 L4 L5 L6 P Q1 Q2 M KRM12-06-02-10 KRM12-06-02-6 99 10 6 6 89 47 1 4 17 19.5 33.5 23.5 33 13.5 8.5 13 19 10 125 6 108 10 55 73 106 104 KRM12-08-03-10 KRM12-08-03-6 3 8 8 19 139 11.5 22.5 37.5 26 36.5 10 15.5 20.5 14.7 86 126 119
Power consumption 110 V AC 0.65VA (5.9mA) 0.55 VA (5 mA) (current value) 200 V AC 1.2VA (6mA) 1.0 VA (5 mA) 220 V AC 1.3VA (5.9mA) 1.1 VA (5 mA) Grommet Grommet L plug connector L plug connector (With indicator light and surge) voltage suppressor L plug connector (With indicator light and surge voltage suppressor) Electrical entry With indicator light and surge voltage suppressor Vacuum
2 (NPN PNP) 10 mA 26.4 V 1 V (10 mA ) 2 LCD 3 7 (/) 6 7 () IP67 8 050 -2070 () 3585RH() AC1000 V 50/60 Hz 1 2 M(DC500 V ) Rc1/8 C 4 6 G1/8(ISO1179-1) F G1/8(ISO1179-1) -15No.PS-OMT0001CN-E 2 ISA3-F ISA3-G ISA3-H M12-4 4 4 5 m 0.72 mm 1.14 mm M12-4 4 4 1.14 mm 23 8 6 5 m46 14 6 5 m 0.50 mm 1.00 mm(26 ) 113 g() CE (EMC RoHS ) 120 2F 3 57 G 20 280 H 20
1 (NPN PNP) 10 mA 26.4 V 1 V (10 mA ) 0.005 mm 0.010 mm 0.020 mm (25 ) 0.010 mm 0.015 mm 0.030 mm 0 0 (3) (20) 2 LCD 3 7 (/) 6 7 () IP67 5 050 -2070 () 3585RH() AC1000 V 50/60 Hz 1 2 M(DC500 V ) Rc1/8 C 4 6 G1/8(ISO1179-1) F G1/8(ISO1179-1) M12-4 4 4 5 m 0.72 mm 1.14 mm M12-4 4 4 1.14 mm 23 5 4 5 m46 8 6 5 m 0.50 mm 1.00 mm(26 ) 113 g() CE (EMC
*1: To use the power of the device, the total load current must be 500 mA or less.
(f) B u L-~ __~~__~~~ ~ Operating piston speed in/s (mm/s) ...J Stoppage Accuracy (Variation In control system is not induded) mm (IN) PI.ton sPMd mm/'sec (I.v.c) Type ot IockJng 50(2) 300(12) 100(4) 500 (20) Spring lock O.4 (C.016) iO.S (O.02) .11.0 (~O .o.I) :::2.0 {:to 08) Air pres.u ... lOCk O 2 (a.008) 0.3 (O.OI 2) O .S (i O .02) =. 1.5 (O .OS) Sori...Alr _roM." I"".
To use the power of the device, the total load current must be 200 mA or less. 2:Refer to 3.3.6 Wiring of contact output signal 3.3 Installation HRL Series 3-18 HRX-OM-W060 Chapter 3 Transport and Setting Up Table 3.3-4 Contact input/output communicatin /Analog output pin number PIN No.
Pressure Range: ISE70 (0 to 1 MPa), Piping: F02 (G 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: 0 to 1 MPa, Piping: G 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -
. = 16 V Example) Load voltage at OFF Leakage current: 1 mA Load impedance: 3 k Load voltage at OFF = Leakage current x 2 pcs. x Load impedance = 1 mA x 2 pcs. x 3 k = 6 V 12 Related Product RoHS For the 12 and 16 JMGP Speed Controller with One-touch Fitting Elbow Type for M3 AS121F-M3-A-X790 Metric size (Color: Light gray) Specifications Flow Rate and Sonic Conductance Inch size (Color: