L1 L2 M Nylon Urethane Weight (g) D 1 8 KGF04-01 KGF04-02 KGF06-01 KGF06-02 KGF06-03 KGF08-01 KGF08-02 KGF08-03 KGF10-02 KGF10-03 KGF12-02 KGF12-03 5.6 15 23 11 16 14 11 13 15 17 13.1 13.1 14 27 31 27.5 31 33.5 29 32.5 33.5 34.5 36.5 35 37 41 4 10 5.6 1 4 17 14 17 19 14 17 19 17 19 17 1 8 15 22 25 17 24 24 27 30 36 31 1 4 12 6 3 8 1 8 1 4 3 8 1 4 3 8 1 4 3 8 11 13 14 14 15 8 18.0 18.5 26.1

L1 L2 M Nylon Urethane Weight (g) D 1 8 KGF04-01 KGF04-02 KGF06-01 KGF06-02 KGF06-03 KGF08-01 KGF08-02 KGF08-03 KGF10-02 KGF10-03 KGF12-02 KGF12-03 5.6 15 23 11 16 14 11 13 15 17 13.1 13.1 14 27 31 27.5 31 33.5 29 32.5 33.5 34.5 36.5 35 37 41 4 10 5.6 1 4 17 14 17 19 14 17 19 17 19 17 1 8 15 22 25 17 24 24 27 30 36 31 1 4 12 6 3 8 1 8 1 4 3 8 1 4 3 8 1 4 3 8 11 13 14 14 15 8 18.0 18.5 26.1

e q w y e q Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VQ7-6-FG-DVQ7-6-FG-D-R o o t r u t r u w y e q w y e q FHG FJG FIG FHG FJG FIG VQ7-6-DVQ7-6-D-R o o t r u t r u w y e q w y e q VQ7-6-FPG-Do t r u w y e q i Replacement Parts (For valve) FHG FJG FIG FHG FJG

e q w y e q VQ7-6-FG-DVQ7-6-FG-D-R o o t r u t r u w y e q w y e q FHG FJG FIG FHG FJG FIG VQ7-6-DVQ7-6-D-R o o t r u t r u w y e q w y e q VQ7-6-FPG-Do t r u w y e q i Replacement Parts (For valve) FHG FJG FIG FHG FJG FIG Description VQ7-6-FG-SVQ7-6-FG-DVQ7-6-FPG-DVQ7-6-FG-S-R VQ7-6-FG-D-R VQ7-6-D-R VQ7-6-DNo.

Refer to the X-axis data set type home position return program and create the Y-axis program. Assign the X inputs, Y outputs, D registers, M contacts and T timers of the Y axis so that they do not overlap those of the X axis. The buffer memory addresses of the QD75 differ between the X and Y axes.

L2-10.5 L1=(28 x n)+36 18 28 28 5.3 F.R.L.

L2-10.5 L1=(28 x n)+36 18 28 28 5.3 F.R.L.

0 y t r q e u q !2 i !1 (A) 4 (B) 2 (A) 4 (B) 2 4(A) SOL.a SOL.b SOL.a SOL.b 5 (EA) 1 (P) 3 (EB) 5 (EA) 1 (P) 3 (EB) 2(B) o 5(EA)/3(EB) 1(P) SJ3B60 [N.O. valve x 2] SJ3B60 [N.O. valve x 2] SJ3B60K with back pressure check valve !0 y t r w e u w !2 i !

Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only)

Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)

Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)

Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)

Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: B (Bracket B), Operation Manual/Calibration Certificate

Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type])

Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate

Pressure Range: ISE71 (0 to 1.6 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)

Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: B (Bracket B)

Connector for unit (Plug) 6 y t y t EX600-DXlB EX600-DYlB EX600-DXlCl q w q w e q w er e y t y t y t EX600-DXlD EX600-DXlE EX600-DYlE EX600-DMlE EX600-DXlF EX600-DYlF EX600-DMlF Analog Unit q w e q w e No.

(a) Delta connection For the 3-phase (L1/L2/L3) delta connection, an instantaneous power failure occurs in the voltage between a pair of lines (e.g. between L1 and L2) among voltages between three pairs of lines (between L1 and L2, L2 and L3, or L3 and L1).

T.T. 60 Push button (Mushroom) VM220-02-30R/B/G/Y VM230-02-30R/B/G/Y JIS Symbol 2 port Panel mounting hole 3 port EXH port (3 port only) 0.5 MPa supply 4.9 mm P.T. 52 N F.O.F. 2-5.5 mounting hole 1.6 mm O.T. 6.5 mm T.T. 5-6-23 22 Series VM200 Series VM200 Push button (Extended) VM220-02-32R/B/G/Y VM230-02-32R/B/G/Y JIS Symbol 2 port 3 port Panel mounting hole EXH port (3 port only) 0.5