Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only)
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: B (Bracket B)
Pressure Range: ISE71 (0 to 1.6 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70),
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE71 (0 to 1.6 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE71 (0 to 1.6 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: B (Bracket B)
Pressure Range: ISE71 (0 to 1.6 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: B (Bracket B)
Type: Pressure Switch, Fluid Type: Air, Maximum Pressure Rating: 1MPa, Minimum Pressure Rating: 0kPa, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Output Method: Switch, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] Rc, Plumbing Thread Nominal: [1/4] 1/4, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 1.5, Operating
Type: Pressure Switch, Fluid Type: Air, Maximum Pressure Rating: 1MPa, Minimum Pressure Rating: 0kPa, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Output Method: Switch, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [NPT] NPT, Plumbing Thread Nominal: [1/4] 1/4, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 1.5, Operating Humidity
DIN Rail Mounting Bracket (Order Separately) ZS 33 R Stations 1 2 3 4 5 1 station 2 stations 3 stations 4 stations 5 stations DIN rail (supplied by customers) Port size F02: G1/4 cannot be mounted on the DIN rail. 919 Series PFM5 Specifications Model PFM510 PFM525 PFM550 PFM511 Dry air, N2, Ar, CO2 (Air quality grade is JIS B8392.1-1, 1.2 to 1.6.2 and ISO8573.1-1, 1.2 to 1.6.2.)
C08 C10 C12 02 N02 F02 C04 C06 C08 02 N02 F02 C08 C10 C12 02 N02 F02 C04 C06 C08 02 N02 F02 IN port size IN port size Construction The construction and materials are the same as the standard product. Refer to Construction on page 323. The symbol stands for unavailable combination. The symbol stands for unavailable combination.
Type: Pressure Switch, Fluid Type: Air, Maximum Pressure Rating: 1MPa, Minimum Pressure Rating: 0kPa, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Output Method: Switch, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] Rc, Plumbing Thread Nominal: [1/4] 1/4, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 1.5, Operating
Type: Pressure Switch, Fluid Type: Air, Maximum Pressure Rating: 1MPa, Minimum Pressure Rating: 0kPa, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Output Method: Switch, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] Rc, Plumbing Thread Nominal: [1/4] 1/4, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 1.5, Operating
Type: Pressure Switch, Fluid Type: Air, Maximum Pressure Rating: 1MPa, Minimum Pressure Rating: 0kPa, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Output Method: Switch, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] Rc, Plumbing Thread Nominal: [1/4] 1/4, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 1.5, Operating