SMC Corporation of America
Elite Part Number Search
Search Results "ISE70-N02-AB-MAY"

Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: B (Bracket B)

Pressure Range: ISE70 (0 to 1 MPa), Piping: F02 (G 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: B (Bracket B)

Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)

Pressure Range: ISE71 (0 to 1.6 MPa), Piping: 02 (Rc 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)

Pressure Range: ISE70 (0 to 1 MPa), Piping: F02 (G 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)

Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)

It may cause an electric shock, fire, or injury. 4. Use only the specified combination between the electric actuator and controller. It may cause damage to the actuator or the controller. 5. Be careful not to be caught or hit by the workpiece while the actuator is moving. It may cause an injury. 6.

Through-hole/Both ends tapped (Standard): MK2TB MK2T-XC89 Lube-retainer Coil scraper 2 x P Cylinder port M A C G thread length H L N C A KA I KK 2 x J 4 x J K D 0.07 0.15 4 x F counterbore C S T AB AA MM KB Q R 2 x E through 2 x FF counterbore (mm) MM KB KK FF AB AA I N M L K J H G F E D C A KA Bore size 32 40 50 63 0.07 0.15 14 50 9 depth 11 9 depth 7 M10 x 1.5 8 4 46 45 34 6 M6 x 1.0 21

If the lock nut is loose, there are sometimes changes in actuator speed which may become dangerous.

In case of Long Stroke For long stroke operation, the cylinder tube may be deflected depending on weight and load; in that case, support the center on the cylinder with a side support so that the supporting interval will be lower than the value shown in the diagram.

Grease may enter into the outlet port of the valve. 2. When using vacuum pressure for the VM100, supply vacuum pressure to P port.

If the exposed tip of the optical cable is dirty, optical transmission may be interrupted and may cause malfunctions. If the tip becomes dirty, wipe with a bonded textileor similar. Do not use a solvent such as alcohol. Click Tab (b) Removal While holding the tab on the SSCNET cable connector, remove the connector.

If the end face of optical code tip is dirty, optical transmission may be interrupted and may cause malfunctions. If the tip becomes dirty, wipe with a bonded textile, etc. Do not use a solvent such as alcohol. Click Tab (b) Removal Whilest holding the tab on the SSCNET cable connector, remove the connector.

If it is pulled off at an angle, the pilot valve may be damaged or the protective O-ring may be scratched. Installation Put the cover back on straight without touching the pilot valve, and push it all the way until the cover's hook locks, without twisting the protective O-ring. (When pushed in, the hook opens and locks automatically.)

This may cause malfunction of the vacuum pump. 6. When the capacity of the vacuum pump is relatively small or when the inside diameter of the piping is small, a change in the set pressure (the pressure difference between the non-flow and flow conditions) may be large. In this case, change the vacuum pump or the inside diameter of the piping.

Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate

Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: Operation