Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket B, Operation Manual/Calibration Certificate: None
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket B, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket B, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Orifice: Orifice shipped with the Product, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -
The ISE70G pressure sensors provide continuous quantitative values, as well as switched digital outputs when pressure set points are met. Compatible fluids include any non-corrosive liquid or gas. 6 pressure ranges are offered up to 50 MPa. This sensor is also IO-Link compatible.
The ISE70G pressure sensors provide continuous quantitative values, as well as switched digital outputs when pressure set points are met. Compatible fluids include any non-corrosive liquid or gas. 6 pressure ranges are offered up to 50 MPa. This sensor is also IO-Link compatible.
Nozzle Diameter: 13 (ø1.3mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: F01 (Screw-in G1/8), VAC: F02 (Screw-in G1/4), EXH: F02 (Screw-in G1/4)
pre-wired connectorSDPC M9BWSDPC *Order part numbers for auto switches alone are D-M9BW(V)L-900, D-M9BW(V)SDPC-900 and DY7BW(V)L-900.
H andl e caref ul l y w hen operat i ng w i t h out put pressure rel eased t o t he at m osphere, as ai r w i l l cont i nue t o f l ow out . I f suppl y pressure t o t hi s product i s i nt errupt ed or shut of f , w hi l e t he pow er i s st i l l on, t he i nt ernal sol enoi d val ve w i l l cont i nue t o operat e and a hum m i ng noi se m ay be generat ed.
R L B 01 1 Nil F G Rc 1 8 ... ...
*r-r-r --r| | | a High-speed | | | response time I I I specifications t t l | | t---{ Pressure display unit | | t--fMfi--l | | f--fkof/cm, l I I [s-f b "t| | I-+-fEr_--] | | tsT kp " ] t l t l I I Cable connector type I S I Straiqht tvpe 3 m I I L I Riqht anqle tvpe 3 m I I j N lWithout cable connector I l L-Bracket Model 7 . l00O tvoe v : 2000 tvoe Pressure [rPa 2 kqf/cm, 3 bar 4 PSI kPa
min (ANR) or less 4.4 L/min (ANR) or less 4.4 L/min (ANR) or less 4.4 L/min (ANR) or less 11.5 L/min (ANR) or less Rc 1/4, 3/8, 1/2 Rc 1/8 (2 locations) Rc 1/4, 3/8, 1/2 Port size Pressure gauge port Rc 1/4 Rc 1/4 Rc 1/8 SRP Ambient and fluid temperature Weight (kg) 5 to 60C (No freezing) 0.64 0.71 0.35 0.30 0.14 SRF Note 1) With the condition of no flow on the output side.
min (ANR) or less 4.4 l/min (ANR) or less 4.4 l/min (ANR) or less 4.4 l/min (ANR) or less 11.5 l/min (ANR) or less (At supply pressure of 1.0 MPa) SRF Rc 1/4, 3/8, 1/2 Rc 1/4 Rc 1/4, 3/8, 1/2 Port size Rc 1/4 Rc 1/8 Rc 1/8 (2 locations) Pressure gauge port ARX20 Ambient and fluid temperature 5 to 60C (No freezing) 0.71 0.35 0.64 Mass (kg) 0.30 0.14 VCHR Note 1) With the condition of no flow
0.1 0.3 0.4 0.6 0.5 0.8 0.7 0.9 300 0 100 200 1.0 Flow rate l/min (ANR) Relief flow rate l/min (ANR) Supply pressure P1 MPa 5 Series IR1000/2000/3000 Series IR2000 Flow rate characteristics Relief characteristics Pressure characteristics Testing methods conform to JIS B8372.