Dynamic moment Va Calculation Example m Operating conditions Cylinder: CYV32 Mounting: Horizontal wall mounting Maximum speed: U = 300 [mm/s] Load mass: m = 1 [kg] (excluding mass of the arm section) L1 = 50 [mm] L2 = 50 [mm] L2 L1 Item Load factor n Note 1. Maximum load mass m 1 = m/m max = 1/5 = 0.20 L2 Review m. L1 2.
Dynamic moment Va Calculation example m Operating conditions Cylinder: CYP32 Mounting: Horizontal wall mounting Maximum speed: U = 300 [mm/s] Load mass: m = 1 [kg] (excluding mass of arm section) L1 = 50 [mm] L2 = 50 [mm] L2 L1 Item Load factor n Note 1. Maximum load mass m 1 = m/mmax = 1/5 = 0.20 L2 Review m. L1 M2 = m g (L1 + B) 103 2.
Dynamic moment Va Calculation example m Operating conditions Cylinder: CYP32 Mounting: Horizontal wall mounting Maximum speed: U = 300 [mm/s] Load mass: m = 1 [kg] (excluding mass of arm section) L1 = 50 [mm] L2 = 50 [mm] L2 L1 Item Load factor n Note 1. Maximum load mass m 1 = m/mmax = 1/5 = 0.20 L2 Review m. L1 2.
Dynamic moment Va Calculation example m Operating conditions Cylinder: CYP32 Mounting: Horizontal wall mounting Maximum speed: U = 300 [mm/s] Load mass: m = 1 [kg] (excluding mass of arm section) L1 = 50 [mm] L2 = 50 [mm] L2 L1 Item Load factor n Note 1. Maximum load mass m 1 = m/mmax = 1/5 = 0.20 L2 Review m. L1 2.
San=a1+a2+a31 3.11-10 Air Slide Table Series MXS Allowable load: W (N) Fig.1 Overhang: Ln (mm), Correction value for moment center distance An (mm) Fig.2 Pitch moment Yaw moment Roll moment W My Mp Mr W W W Static moment Dynamic moment L1 A1 L3 A5 L2 A3 CL W Mp Mr My W W MLGC L3 A6 W L1 A2 L2 A4 CNA W Mey Mep CB L2 A4 CV/MVG A2 L3 Work mounting coefficient: K Fig.3 CXW Table mounting CXS
Pressure Range: ISE76G (0 to 5 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: M (SI Unit Only)
Pressure Range: ISE76G (0 to 5 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE76G (0 to 5 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE76G (0 to 5 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE75[H]), Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate)
Pressure Range: ISE76G (0 to 5 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)
Pressure Range: ISE76G (0 to 5 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)
Pressure Range: 0 to 5 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 5 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 5 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 5 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate
Pressure Range: 0 to 5 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 5 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
1 5 Port Air Operated Valve Series SYA3000/5000/7000 How to Order SA One-touch fitting (Inch size) A, B port size Thread type VA Thread piping Nil Rc Symbol Port size Applicable series M5 01 02 Symbol Port size Applicable series N3 N7 N3 N7 N9 N7 N9 G F SA 5 32" SYA3000 SYA5000 SYA7000 One-touch fitting for M5 x 0.8 N NPT SYA3000 1 4" 1 8 1 4 One-touch fitting for NPTF T VA 5 32" One-touch
-02/03 3 (Exhaust center) Rc 1/4: 17 VH302-02/03 VH312-02/03 2 (Position) 1 (P) 3 (R) 2 1 VH3 0.71 1/4, 3/8 VH320-02/03 VH330-02/03 3 (Closed center) Rc 3/8: 20 Exhaust center VH321-02/03 VH331-02/03 3 (Exhaust center) (A) 2 (B) 4 VH322-02/03 VH332-02/03 2 (Position) 12 3 4 VH400-02 to 06 VH410-02 to 06 3 (Closed center) 1 (P) 3 (R) Rc 1/4: 45 4 3 VH401-02 to 06 VH411-02 to 06 3 (Exhaust
1 5 Port Air Operated Valve Series VFA3000 How to Order SA Thread type (Including pilot port) VA Nil F N T Rc G NPT NPTF SA Port size (P, A, B port) VA 01 02 1 8 1 4 Option R1, R2 port are 1/8.