Positioning distance (mm) 600 300 100 10 1 10 60.5 30.5 10.5 1.5 0.5 100 6.5 3.5 1.5 0.6 0.5 Speed (mm/s) 250 2.9 1.7 0.9 0.6 0.5 500 1.8 1.2 0.8 0.6 0.5 Values will vary slightly depending on the operating conditions.
/s) 50 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 C85 -XC3 Special port location 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper C95 80 1400 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Heat resistant cylinder (110 C) -XC5 100 1500 25, 50, 75, 100, 125, 150, 175
/s) 50 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 C85 -XC3 Special port location 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper C95 80 1400 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Heat resistant cylinder (110 C) -XC5 100 1500 25, 50, 75, 100, 125, 150, 175
AC voltage valves there is no S option.
Stations J kit (Flat ribbon cable) G kit (Flat ribbon cable with terminal block) P kit (Flat ribbon cable) F kit (D-sub connector) Cylinder port Kit U S A U S P 26P 20P J U S U S F 15P U S P 16P U S B P 20P U S C P A 10P F 25P G Type Negative common specifications Max. points 24 14 24 18 14 8 16 16 Electrical entry Cable length M kit (Circular connector) T kit (Terminal block box) S kit (
Stations J kit (Flat ribbon cable) G kit (Flat ribbon cable with terminal block) P kit (Flat ribbon cable) F kit (D-sub connector) Cylinder port Kit U S A U S P 26P 20P J U S U S F 15P U S P 16P U S B P 20P U S C P A 10P F 25P G Type Negative common specifications Max. points 24 14 24 18 14 8 16 16 Electrical entry Cable length M kit T kit (Terminal block box) S kit 0 1 2 With cable (0.6
Stations J kit (Flat ribbon cable) G kit (Flat ribbon cable with terminal block) P kit (Flat ribbon cable) F kit (D-sub connector) Cylinder port Kit U S A U S P 26P 20P J U S U S F 15P U S P 16P U S B P 20P U S C P A 10P F 25P G Type Negative common specifications Max. points 24 14 24 18 14 8 16 16 Electrical entry Cable length M kit T kit (Terminal block box) S kit 0 1 2 With cable (0.6
250 =0.7 200 0.5 150 0.1 0.3 100 50 0 1,000 2,000 3,000 Maximum speed Vmax [mm/s] : Cylinder load factor Vmax : Maximum speed (Refer to page 24) 16
VBAT10A1 S Note) A safety valve port is provided only when option R or S is selected.
(For DIN rail mounting) (7.5) Manifold block internal wiring specifications 11.8 S: Single wiring D: Double wiring L Dimension n: Stations L n 2 198 187.5 162.8 17.5 63 3 198 187.5 173.3 12.5 73.5 4 210.5 200 183.8 13.5 84 5 223 212.5 194.3 14.5 94.5 6 235.5 225 204.8 15.5 105 7 248 237.5 215.3 16.5 115.5 8 260.5 250 225.8 17.5 126 9 260.5 250 236.3 12 136.5 10 273 262.5 246.8 13 147 11 285.5
or 3/8" 67.0 67.0 60 121 7380 1 10 mm or 3/8" 75 189 11500 1 10 mm or 3/8" 502 195 11900 1 10 mm or 3/8" 130.0 130.0 602 282 17200 1 10 mm or 3/8" 752 441 26900 1 10 mm or 3/8" B1J B1JA Stroke volume dm3 / in3 NPT Piping Air (s) Spring (s) Piping Air (s) Spring (s) Piping Air (s) Spring (s) 6 0.47 28.7 3/8 10 mm or 3/8" [6 mm or 1/4" (x)] 10 mm or 3/8" [6 mm or 1/4" (x)] 8 0.9 55
Bore size (mm) Maximum stroke Standard stroke (mm) 32 700 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 40 800 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80 1400 25, 50, 75, 100, 125, 150, 175
: 500 mm/s Operating pressure: 0.6 MPa Load weight: 200 kg 300 Load weight m (kg) 250 63 200 Since the conditions are horizontal extension with a speed of 500 mm/s, use graph (5).
S L, Z S L, Z 1 1 1 1 4 1 2 PB AC 2 Ordering example (Example) Series VXR22, Rc 1 1/4, 200 VAC, Conduit terminal (Part no.)
745 550 300 860 1650 2105 120 250 80 (3B) 100 (4B) 150 (6B) 65 (2 1/2B) 65 (2 1/2B) 630 920 37 750 24 317 795 600 300 880 1410 1865 120 250 80 (3B) 100 (4B) 150 (6B) 65 (2 1/2B) 65 (2 1/2B) 710 970 37 1000 24 394 795 600 300 880 1670 2125 120 250 80 (3B) 100 (4B) 150 (6B) 65 (2 1/2B) 65 (2 1/2B) 735 970 53 750 24 373 845 650 300 890 1420 1880 120 250 80 (3B) 100 (4B) 150 (6B) 65 (2 1/2B)
L Speed: V [mm/s] a1 a2 T1 = V/a1 = 300/3000 = 0.1 [s], T3 = V/a2 = 300/3000 = 0.1 [s] Time T = T1 + T2 + T3 + T4 [s] [s] L 0.5 V (T1 + T3) V T1: Acceleration time and T3: Deceleration time can be found by the following equation.
Maximum piston speed: 1000 mm/s It can be used at 50 to 1000 mm/s provided that it is within the allowable kinetic energy range.
Standard Stroke/ Bore size (mm) 32 40 50 63 80 100 Standard stroke (mm) 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 25, 50, 75, 100, 125, 150, 175, 200, 250, 300
Note 4) Interface regulator is only capable of regulating the P port pressure. 0.06 1.9 2.1 4.5 4.5 P A P B A EA B EB Effective area at supply side (mm2) (3) S at P1 = 0.7 MPa, P2 = 0.5 MPa Effective area at exhaust side (mm2) (3) S at P2 = 0.5 MPa How to Order Solenoid Assembly Non plug-in type C DXT170 5 L Flow Characteristics {1(P) 4(A)} Conditions: Inlet pressure setting 0.7 MPa