These vortexes are stable under certain conditions, and their frequency is proportional to the flow velocity, resulting in the following formula. f = k x v f: Frequency of vortexes, v: Flow velocity, k: Proportional constant (determined by the vortex generator's dimensions, shape, etc.) Therefore, the flow rate can be measured by detecting this frequency.
Symbol: 10R2 (Body Ported, 2 Port, N.O., Port 3 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 300mm, CE Compliant: Q (CE Compliant)
Symbol: Body Ported, 2 Port, N.O., Port 3 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 300mm, CE Compliant: CE Compliant
At temperatures of 5C or lower, take measures to prevent freezing, since moisture in circuits may be frozen and this can cause damage to seals and lead to malfunction. Refer to SMCs Air Cleaning Equipment catalog for further details on compressed air quality. Piping Caution 1.
VH600 Cast iron Cast iron q w Cover Body Replacement Parts Part No. of Lock Nut for Panel Mounting Part no. VH200 244026 244026-1 Series VH200 VH300 VH400 Part no. 244010 24418 240258 Material No.
Buffer stroke 25 50 75 100 40 50 63 80 100 125 Series ZPT ZPX Pad Material and Characteristics : Little or no influence : Can be used depending on conditions X: Not suitable Characteristics Operating temperature range (C) Oil resistance gasoline Oil resistance benzol Solvent resistance (Benzene, toluene) Durometer HS (5C) Base resistance Acid resistance Abrasion resistance Ozone resistance
Example of a Basic Circuit Diagram Two Hand Control Valve Push button operated valve Cylinder Air operated valve Push button operated valve 1682 Two Hand Control Valve VR51 Series Construction q t !1 i !8 y e !0 P1(11) port u R(4) Exhaust port r !5 o !7 A(2) port P2(12) port w !2 !6 !4 !
Take measures to prevent freezing, since moisture in circuits will be frozen under 5C, and this may cause damage to seals and lead to malfunction. Refer to the "Compressed Air Cleaning Systems" catalog for details on compressed air quality. 2. Do not operate with the cushion needle in a fully closed condition.
Active face A (upper switch) becomes covered at open limit of travel and face K (lower switch) at closed limit.
Temperature J Nylon 140F (60C) K Neoprene 230F (110C)* *Max Temperature is for boot only How To Order MOUNTING BORE STROKE CUSHION BOOT NCA1 Rod boots are used to protect the surface of a piston rod in harsh environments.
(Example) CLK1GA50-100Y-B None Single knuckle joint Double knuckle joint None With limit switch mounting base With dog fitting With pedestal (for 75, 100, 150 strokes only) Nil B D K Note 2) Port position Note 1) Accessories (options) are not available with 32. Note 2) Clevis width B (19.5mm) is not available with mounting base K. Note 3) List the necessary options.
Ambient and fluid temperature range is as follows: Digital pressure switches: 0 to 50C Other pressure switches: 0 to 60C Take measures to prevent freezing of moisture in circuits below 5C, since this may cause damage to the O-ring and lead to malfunction. The installation of an air dryer is recommended for eliminating condensate and moisture.
Symbol: 10R2 (Body Ported, 2 Port, N.O., Port 3 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 1 (Bracket), Lead Wire Length: K (Plug Connector, 300mm)
Symbol: 10R2 (Body Ported, 2 Port, N.O., Port 3 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: K (Plug Connector, 300mm)
Symbol: 10R2 (Body Ported, 2 Port, N.O., Port 3 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 3 (Bracket + Manual Override), Lead Wire Length: K (Plug Connector, 300mm)
Symbol: Body Ported, 2 Port, N.O., Port 3 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket, Lead Wire Length: Plug Connector, 300mm, CE Compliant: -
Symbol: Body Ported, 2 Port, N.O., Port 3 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: Plug Connector, 300mm, CE Compliant: -
Symbol: Body Ported, 2 Port, N.O., Port 3 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: Plug Connector, 300mm, CE Compliant: -
When the rotational axis and load center of Rectangular parallelepiped) Position of rotational axis: Perpendicular to the plate through the center of gravity gravity are not consistent L r 2 I = K + mL K: Moment of inertia around a b the load center of gravity 2 2 b a I = m 12 2 r 4.Round plate K = m2 9. Gear transmission 4.
When the rotational axis and load center of Rectangular parallelepiped) Position of rotational axis: Perpendicular to the plate through the center of gravity gravity are not consistent L 2 r I = K + mL K: Moment of inertia around a b the load center of gravity 2 2 b a + 2 r I = m 12 4.Round plate K = m2 9. Gear transmission 4.