160 200 50 100 150 200 Load (N) Load (N) Load (N) 8-6-5 6 Series MXF Model Selection Model Selection Step Formula/Data Selection Example Operating Conditions 1 Cylinder: MXF20-50 Cushion: Rubber bumper Workpiece table mounting Mounting: Horizontal wall mounting Average speed: Va = 300 [mm/s] Allowable load: W = 0.5 [kg] L1 = 10 mm L2 = 30 mm L3 = 30 mm Kinetic Energy Model to be used Type

Lead wire length (m) Load voltage Auto switch model Electrical entry direction Indicator light Type Electrical entry Pre-wired connector Wiring (output) Special function Applicable load 0.5 (Nil) 1 (M) 3 (L) 5 (Z) AC DC Perpendicular In-line M9NV M9PV M9BV M9NWV M9PWV M9BWV M9NAV1 3-wire (NPN) M9N M9P M9B M9NW M9PW M9BW M9NA1 5 V, 12 V IC circuit Reed auto switch Solid state auto switch 3

Roller Type/Round Bar Type/ Chamfered Type Graph (1) Lever Type (With shock absorber) Friction coefficient = 0 Graph (2) Lever Type (With shock absorber) Friction coefficient = 0.1 Graph (3) 100 200 200 50 130 130 50 50 100 100 50 40 40 40 40 Example 1 30 40 50 40 50 Weight of transferred object m (kg) Weight of transferred object m (kg) Weight of transferred object m (kg) 20 30 30 Example

Yes A90V Grommet IC circuit 100 V or less No Yes No Yes No 100 V, 200 V Relay PLC 200 V or less 12 V Connector 2-wire 24 V IC circuit 24 V or less PLC Terminal conduit 100 V, 200 V Yes Relay PLC DIN terminal Grommet Diagnostic indication (2-color indicator) 1 Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance

300 40 30 20 10 0 30 25 20 15 10 5 0 Load (N) Load (N) MSQXB30A MSQXB50A 350 300 300 250 Displacement (m) Displacement (m) 250 200 200 150 150 100 100 50 40 30 20 10 0 100 80 60 40 20 0 Load (N) Load (N) 336 MSQX Series Low-Speed Rotary Table Rack & Pinion Type Construction CRB2 CRB1 MSU CRJ CRA1 o i @5 @6 t y !

mm/s or less L = 100 mm, V = 200 mm/s or less 10 10 Load mass m [kg] Load mass m [kg] 1 1 0.3 0.3 10 30 31 101 200 100 10 30 31 100 101 200 Stroke [mm] Stroke [mm] MGPKL32 L = 50 mm, V = 200 mm/s or less L = 100 mm, V = 200 mm/s or less 50 50 Load mass m [kg] Load mass m [kg] 10 10 3 3 10 50 51 100 101 200 100 101 200 10 50 51 Stroke [mm] Stroke [mm] 21 Model Selection MGPK Series L L Plate

Seal kit includes a grease pack (125 to 160: 40 g, 180, 200: 50 g, 250: 60 g). Order with the following part number when only the grease pack is needed.

MY1MW32 MY1MW32 5 4 0.5 0.4 MY1MW32 MY1MW32 MY1MW25 MY1MW25 3 MY1MW25 MY1MW25 0.3 1 MY1MW20 MY1MW20 MY1M20 MY1MW25 MY1MW25 2 0.2 MY1MW20 MY1MW20 MY1MW20 MY1MW20 0.5 MY1MW16 MY1MW16 MY1MW16 MY1MW16 0.4 1 0.1 MY1MW16 MY1MW16 0.3 0.2 100 200 300 400 500 1000 1500 0.05 0.5 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 Piston speed (mm/s) Piston speed (mm/s) Piston speed (mm/s)

1 y, z + A = 200 y, z + A = 300 1 y, z + A = 200 0.1 y, z + A = 300 0.01 0.1 0 200 400 600 800 1000 1200 1400 1600 0 200 400 600 800 1000 1200 1400 1600 Stroke [mm] Stroke [mm] [Graph 7] Allowable load mass by stroke 40 100 y, z + A = 0 y, z + A = 50 Load mass [kg] y, z + A = 100 y, z + A = 200 10 y, z + A = 300 1 0 200 400 600 800 1000 1200 1400 1600 If load center of gravity exceeds the

, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 25 3000 32 40 3000 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 5000 63 Note 1) Long stroke type (XB11) applies to the strokes exceeding 2000 mm.

160 180 200 0.1 0 40 60 80 100 120 140 160 180 200 20 20 Overhang L (mm) Overhang L (mm) Graph (21) Stroke: Up to 200 stroke Graph (17) Stroke: Up to 200 stroke 10 20 10 20 2 3 4 5 2 3 4 5 Weight W (kg) Weight W (kg) 40 40 32 32 1 1 0.5 0.4 0.3 0.2 0.5 0.4 0.3 0.2 25 20 25 20 0.1 0.1 100 120 140 160 180 200 0 40 60 80 100 120 140 160 180 200 0 40 60 80 20 20 Overhang L (mm) Overhang L (mm

400 500 100 200 300 400 600 500 100 200 300 400 600 Load (N) Load (N) Load (N) 8-7-5 6 Long Stroke Slide Table Series MXW 8, 12, 16, 20, 25 How to Order MXW 16 100 B M9N S Number of auto switches Nil S n 2 pcs. 1 pc. n pcs.

Maximum Allowable Moment MY1B/M1 MY1B/M2 MY1B/M3 200 300 400 500 40 50 100 30 200 20 50 40 30 100 10 20 40 50 3 4 5 30 10 20 Moment Nm Moment Nm Moment Nm 2 5 4 3 10 1 MY1B40 MY1B40 5 4 3 2 MY1B40 MY1B40 MY1B40 MY1B40 0.3 0.4 0.5 MY1B32 1 2 MY1B32 MY1B32 MY1B25 0.2 1 0.5 0.4 0.3 MY1B25 MY1B25 0.1 0.4 0.5 0.2 0.3 0.05 0.04 0.03 0.2 0.1 0.02 0.06 0.1 100 200 300 400 500 1000 1500 100 200 300

distance l (mm) 10 400 Eccentric distance l (mm) MGTL100 300 200 300 MGTM100 200 P = 0.5 MPa 100 P = 0.5 MPa Load weight m(kg) Larger than 75st Load weight m(kg) 40 50 100 Larger than 50st 50st 25st 30 25, 50st 20 50 40 10 30 5 4 3 2 20 1 10 20 30 40 50 100 200 300 1 2 3 4 5 10 20 304050 100 200 300400 Eccentric distance l (mm) 10 400 Eccentric distance l (mm) Allowable side load F(N) 1

Mounting side Closed C B A A Open D Open E F F Mounting side MHL2-25DZ-X86/X86A MHL2-25D Z-X86/X86A 1 2 200 200 160 160 Gripping force [N] Gripping force [N] Pressure 0.6 MPa Pressure 0.6 MPa 0.5 MPa 120 120 0.5 MPa 0.4 MPa 0.4 MPa 80 80 0.3 MPa 0.3 MPa Closed F (Fingers closed) 40 40 0 0 40 80 120 160 200 0 0 40 80 120 160 200 [mm] Model A B C D E F Weight [g] MHL2-25DZ-X86(A) 9 106 128

300 400 500 1000 1500 Piston speed mm/s 100 200 300 400 500 1000 1500 Piston speed mm/s 100 200 300 400 500 1000 1500 Piston speed mm/s MY2C MY2 H/HT Maximum Load Mass Select the load mass from within the range of limits shown in the graphs.

Bore size (mm) Standard stroke (mm) Maximum manufacturable stroke (mm) 10 15, 30, 45, 60, 75, 100, 125, 150 400 16 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 400 Symbol Specifications -XAl Change of rod end shape -XC3 Special port location -XC9 Adjustable stroke cylinder/Adjustable retraction type Note 1) Manufacture of intermediate strokes at 1 mm intervals is possible.

Lead wire length (m) Load voltage Auto switch model Electrical entry direction Special function Electrical entry Indicator light Wiring (Output) 0.5 (Nil) 3 (L) Applicable load Type AC DC 12 V In-line 24 V 100 V 12 V 2-wire Reed auto switch Grommet Yes Relay, PLC A93 3-wire (NPN) M9N 24 V Solid state auto switch Grommet Yes Relay, PLC 12 V 2-wire M9B Lead wire length symbols

Lead wire length (m) Load voltage Auto switch model Electrical entry direction Indicator light Electrical entry Special function Wiring (Output) 0.5 (Nil) 3 (L) Applicable load Type AC DC 12V In-line Yes Grommet 24V 100V 12V Reed switch 2-wire Relay, PLC A93 3-wire (NPN) M9N Yes Grommet 24V Solid state switch Relay, PLC 2-wire 12V M9B Lead wire length symbols: 0.5mNil (Example)