S M U D J Bracket (Option) AR20(K)-B to AR40(K)-06-B 2 x P1 Panel fitting dimensions A (Port size) Y W C B Q V K OUT OUT IN IN Z Plate thickness AR20(K)-B to AR30(K)-B: Max. 3.5 AR40(K)-B : Max. 5 R F P2 S (Pressure gauge port size) Bracket (Option) U M J D T N AR50(K)-B/AR60(K)-B 2 x P1 A (Port size) B Q C K OUT IN R F P2 S (Pressure gauge port size) Bracket (Option) T N J M D U 73 Regulator
E 03 05 07 09 't't 5132" 1l4', 5/16' 3t8" 1/2" 6mm 8mm H , T , U , X , N 1 3 06 08 t0 1 2 1 6 32 i10-32 UNF Thread 3 5 I l t N P r H ' L . W , r .
Micromesh element (SUS304) Bonding material: Epoxy resin Q005 FQ1 0 1 1 B 06 N Part number Dimensions Filtration accuracy (m) Element symbol Element type Select from tables on the right.
As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.
Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order. q Symbol Description Body size 20 40 60 30 Nil K Note 1) Without backflow function With backflow function With backflow function w + Nil N Note 2) F Note 3) Thread type Rc NPT G e + 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 Port size r + Nil B Note 5) H Note 4) a Without mounting option
Micromesh element (SUS304) Bonding material: Epoxy resin Q005 FQ1 0 1 1 B 06 N Part number Dimensions Filtration accuracy (m) Element symbol Element type Select from tables on the right.
ASD Body size Port size M5 M5 x 0.8 U10/32 10-32UNF 1 M5 x 0.8 10-32UNF AS AS-FE 2 F A 1 AS 1 M5 06 0 E Body size 1 KE AS-FG F A 1 AS 2 01 06 2 0 S Body size 2/3/4 AS-FP AS-FM Body size Made to Order Refer to page 562 for details.
As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.
As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.
Caution REC25 101110-AS2001F-06-X214 10-AS2301F-01-06-X214 10-AS2201F-01-06-X214 REC32 101110-AS3001F-08-X214 10-AS2301F-01-06-X214 10-AS2201F-01-06-X214 REC40 101110-AS3001F-08-X214 10-AS3301F-02-08-X214 10-AS3201F-02-08-X214 2. Speed control is possible with meter-in and meter-out types of speed controllers.
N H (Hex.) Applicable tube O.D.
L* N x 4 N x 8 N x 12 N x 6 N x 12 N x 18 N x 8 N x 16 N x 10 N x 20 N x 12 N x 24 D 18 28 28 24 37 37 31 42 52 52 67 67 TCU0425-1N-X6 TCU0425-2N-X6 TCU0425-3-N-X6 TCU0604-1-N-X6 TCU0604-2-N-X6 TCU0604-3-N-X6 TCU0805-1-N-X6 TCU0805-2-N-X6 TCU1065-1-N-X6 TCU1065-2-N-X6 TCU1208 -1-N-X6 TCU1208 -2-N-X6 LX5.9 + 200 LX4.4 + 200 LX2.9 + 200 LX5.3 + 200 LX3.8 + 200 LX2.5 + 200 LX5.2 + 200 LX3 +
PF25 SEMI-F47 (Tough Drive )] (a)DC158V Tough DriveDC158V[AL. 10] O N OFF [Pr. PF25] (DC 158 V) ALM ( ) O N OFF WNG ( ) O N OFF MTTR ( Tough Drive ) O N OFF MBR () O N OFF O N OFF 7 24 7. (b) DC158V ON OFF [Pr. PF25] (DC 158 V) ON OFF ALM ( ) ON OFF WNG ( ) ON OFF MTTR ( Tough Drive ) MBR ON OFF () ON OFF 7 25 7. 7.4 SEMI-F47 SEMI-F47 LECSS2-TSEMI-F47 (1) [Pr.
AN103-01 AN203-02 AN303-03 AN403-04 5-10-3 4 Silencer Metal Case Type Series 25 How to Order Exhaust in only one direction Prevents scattering of mist and noise. 25 10 002 Port size Thread type Body size 002 003 004 006 010 1/4 3/8 1/2 3/4 1 R NPT Nil N 04 05 06 07 08 10 11 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside
ZZX1 06 Manifold base Supply port location Stations Thread of supply and exhaust valve Right side Left side Both sides R L B 01 1 ZX Note) Exhaust port is both sides release type. ... ...
N) 99(4) 100(4) AC DC AC/DC 60 40 1 80 60 10(1) 60 40 40 60 Maximum Minimum 10 5(2) Note 1) Dew point: 10C or less Note 2) 50 cSt or less Note 3) D, E, N, P etc. in parentheses are option symbols.
Control type 04 06 4 6 Port size 0 1 Meter-out Meter-in M3 M5 01 02 M3 x 0.5 M5 x 0.8 R 1/8 R 1/4 With One-touch fitting Fixed orifice Applicable model AS121F-M3-04 AS121F-M5-04 AS121F-M5-06 AS221F-01-04 AS221F-01-06 AS221F-02-06 Symbol Fixed orifice 1 2 3 4 5 6 7 8 9 10 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 The graph below shows the relationship between orifices for each cylinder bore
Body size Port size Thread type Nil N F Symbol Port size Rc NPT G 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 A spacer or spacer with bracket is required if the valve is combined with modular FRL. SUP SUP Applicable air preparation equipment Spacer with bracket part no. Pressure relief 3 port valve VHS20 VHS30 VHS40 VHS40-06 VHS50 IN OUT Spacer part no.