-XC22 Fluororubber seal Auto switch -XC25 No fixed throttle of connection port -XC85 Grease for food processing equipment -X446 PTFE grease DRefer to pages 262 to 266 for cylinders with auto switches.
Seals made of fluorine rubber -XC22 Seal materials are changed to the fluorine rubber. Low speed (10 to 50 mm/s) -XB9 XC22 Enter the applicable model number. XB9 Enter the applicable model number.
: Fluoro Rubber Seals Symbol -XC22 26 Fluoro Rubber Seals Standard model no.
Grease pack part number: GR-T-005 (5 g) XC22/Fluororubber seal CJP2B6D-XC22-PS 6 10 16 CJP2B6D-XC22-PS CJP2B10D-XC22-PS CJP2B16D-XC22-PS Set of left nos. !0, !1, !2. CJP2B10D-XC22-PS CJP2B16D-XC22-PS Seal kit includes a grease pack (5 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-L-005 (5 g) 6
XC22 CA2 CA2W Fluoro rubber seal Specifications Mounting Bore size Stroke A Suffix Stroke B-A Suffix CA2 XC11 Double acting, Single/Double rod Fluoro rubber Specifications and dimensions other than the above are the same as the standard type.
-XC22 5 Fluoro Rubber Seals Specifications MGPM XC22 Bore size Stroke MGPM Applicable series Slide bearing Bearing type Fluoro rubber seals 12, 16, 20, 25, 32, 40, 50, 63, 80, 100 Cylinder bore size (mm) None Cushion Seals are changed to a fluoro rubber material which has outstanding resistance to chemicals. Mountable Auto switch 1. Dimensions are the same as standard products. 2.
Magnet: Built-in, Mounting: MS2, Side Lug, Bore Size: 3 1/4", Stroke: 16", Air Cushion: Both Ends (Air Cushion), Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Viton Seals
Magnet: Built-in, Mounting: MP4, Single Detachable Rear Clevis, Bore Size: 2 1/2", Stroke: 16", Air Cushion: Both Ends (Air Cushion), Auto Switch: A53--Reed, DC Volt >5<24, LED, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Viton Seals
Magnet: Built-in, Mounting: MT2, Head trunnion, Bore Size: 2", Stroke: 16", Air Cushion: Both Ends (Air Cushion), Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Viton Seals
Magnet: Built-in, Mounting: MT1, Rod Trunnion, Bore Size: 3 1/4", Stroke: 16", Air Cushion: Both Ends (Air Cushion), Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Viton Seals
stainless steel 20 to 100 Note 6) v v XC8 Adjustable stroke cylinder/Adjustable extension type XC9 Adjustable stroke cylinder/Adjustable retraction type v v XC10 Dual stroke cylinder/Double rod type v 20 to 63 XC11 Dual stroke cylinder/Single rod type v XC12 Tandem cylinder v v v Note 15) XC13 Auto switch rail mounting 20 to 100 v v v XC20 Head cover axial port 20 to 63 v v XC22
-XC6 Piston rod and rod end nut made of stainless steel -XC8 Adjustable stroke cylinder/Adjustable extension type Theoretical Output -XC9 Adjustable stroke cylinder/Adjustable extension type -XC22 Fluoro rubber seals OUT IN -XC35 With coil scraper (N) -XC69 With shock absorber Rod size (mm) Operating direction Piston area (mm2) Operating pressure (MPa) Bore size (mm) -XC79 Machining tapped
400 15 400 3 40 500 20 500 50 500 40 500 20 500 4 50 600 25 600 60 600 50 600 25 600 5 60 700 30 700 80 700 60 700 30 700 6 80 800 40 800 100 800 80 800 40 800 7 100 900 50 900 200 900 100 900 50 900 8 150 1000 75 1000 300 1000 200 1000 75 1000 9 200 1200 100 1200 400 1200 250 1200 100 1200 10 250 1400 125 1400 500 1400 300 1400 125 1400 11 300 1600 150 1600 600 1600 400 1600 150 1600 12
v 32 to 125 XC7 Tie-rod, cushion valve, tie-rod nut, etc. made of stainless steel v v v v XC8 Adjustable stroke cylinder/Adjustable extension type v v XC9 Adjustable stroke cylinder/Adjustable retraction type v v XC10 Dual stroke cylinder/Double rod type v v XC11 Dual stroke cylinder/Single rod type v v XC12 Tandem cylinder v v v v v v XC14 Change of trunnion bracket mounting position XC22
Other specifications and dimensions 7 -XC22 Fluoro rubber seal Specifications CXS XC22 Auto switch Bore size Stroke Slide bearing CXSL CXSM Series Bearing type Ball bushing bearing Fluoro rubber seal 6, 10, 15, 20, 25, 32 Bore size (mm) Without auto switch: 10C to 70C With auto switch: 10 to 60C (with no freezing) Chemical-resistant fluoro rubber is used for seal materials.
NPT ports Mounting type MB1 XC11 Bore size Stroke A Suffix Stroke B Suffix Fluoro rubber seals XC22 16 Dual stroke cylinder single rod type Seal material is changed to fluoro rubber for superior chemical resistance.
400 600 800 1000 1200 1400 1600 Speed [mm/s] 0 200 400 600 800 1000 1200 1400 1600 Speed [mm/s] LEC Y LEC Y Regenerative resistor area Applicable Motor/Driver Motorless * When using the actuator in the Regenerative resistor area, download the AC servo capacity selection program/SigmaJunmaSize+ from the SMC website.
1600 1890 1606 1730 18 8 1600 1700 1990 1706 1830 20 9 1800 1800 2090 1806 1930 20 9 1800 1900 2190 1906 2030 22 10 2000 2000 2290 2006 2130 22 10 2000 2500 2790 2506 2630 28 13 2600 Encoder cable (7) Motor cable (7) Note 1) When mounting the actuator using the body mounting reference plane, set the height of the opposite surface or pin to be 3 mm or more because of R chamfering.
Model LEFB25 LEFB32 LEFB40 300, 400, 500 600, 700, 800 900, 1000, (1100) 1200, (1300, 1400) 1500, (1600, 1700) (1800, 1900), 2000 2500 300, 400, 500 600, 700, 800 900, 1000, (1100) 1200, (1300, 1400) 1500, (1600, 1700) (1800, 1900), 2000 2500, 3000 300, 400, 500 600, 700, 800 900, 1000, (1100) 1200, (1300, 1400) 1500, (1600, 1700) (1800, 1900), 2000 LEF Stroke [mm] Note 1) LEJ Actuator specifications
300 mm 300 mm 300 mm 4 s 4 s 6 s 6 s 8 s 0 8 s 0 8 s 2 s 4 s 6 s 8 s 0 2 s 4 s 6 s 8 s 0 2 s 2 s 300 mm 300 mm 300 mm 300 mm 0 400 800 1200 1600 2000 Installation distance [mm] 0 400 800 1200 1600 2000 Installation distance [mm] 0 2000 0 400 800 1200 1600 2000 Installation distance [mm] 0 400 800 1200 1600 2000 Installation distance [mm] 1600 2000 m] Extensive static neutralization area can