Standard part number MB1 XC35 With coil scraper Specifications Action Cushion Wiper ring Double acting single rod Air cushion, Rubber bumper Coil scraper (metal) Specifications other than the above are the same as the standard type.

Example: Part Number *NVSA 4114-52AM =A |NVSA 4114.00A vatve mounled on *ISPA 0112 subplate with a #SPA 0100 Interlace Spaed Control between.

[PA04] = 0100. Set the "PA04" to "0100" in the "Basic" tab. Click on the "Single Axis Write" button. Turn the power OFF and ON again. Parameter is enabled. -24- 6.3.6 Absolute position detection system *If you use the absolute position detection system, set parameter: [PA03]=0001. Refer to "LECSS Operation Manual, chapter 12 for details.

v v CG1lR V v v CG1lM MB MB1 v v XB6 Note 2) Note 2) Note 15) v XB7 CA2 v v v XB9 Note 15) v XB13 Note 15) CS1 v v v v XC4 CS2 v v XC6 v v v v v XC8 Note 15) Note 13) Note 13) v v v v v XC9 Note 15) Note 14) Note 14) v v v v v v v XC10 v v v v v v v XC11 v v v v v XC12 v v v v XC13 v v v v XC20 Note 15) v v v XC22 Note 2) v v v v v v XC27 v v v v v v v XC29 v v v v XC35

to 63 only -XB18 Low friction cylinder, 32 to 100 only -XC4 With heavy duty scraper, 20 to 100 only -XC6 Piston rod and rod end nut made of stainless steel -XC8 Adjustable stroke cylinder/Adjustable extension type -XC9 Adjustable stroke cylinder/Adjustable retraction type -XC10 Dual stroke cylinder/Double rod type -XC11 Dual stroke cylinder/Single rod type -XC18 NPT finish piping port -XC35

Double clevis pin and double knuckle pin made of stainless steel -XC27 200 998 250 813 -XC30 Front trunnion 300 564 -XC35 With coil scraper 6-9-3 4 Series CS1 Principal Parts Material and Surface Treatment Precautions Description Material Note Cover Rolled steel plate Black painted Be sure to read before handling.

Bore size (in) 1.50 2, 2.50 3.25, 4 Standard stroke 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24, 28 How to Order Mounting Bore Stroke NC D A1 XC35 Ex: NCDA1B 150-0400-XC35 With coil scraper Auto switch capable 6-15-33 33 Series NCA1 Accessory Bracket Dimensions Eye Bracket Part no.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com -XC11 Dual stroke cylinder/Single rod type -XC18 NPT finish piping port -XC35 With coil scraper, 32 to 100 only -XC36 With boss in rod side -XC58 Water resistance improved type/Built-in hard plastic magnet, 20 to 100 only -XC59 Fluoro rubber for seal/

-XC9 Adjustable stroke cylinder/Adjustable retraction type -XC35 With coil scraper Applicable stroke (mm) -XC79 Machining tapped hole, drilled hole, and pin hole additionally. Caution Example Positioning accuracy for pin hole on the plate Dispersion of dimensions when machining each component will be accumulated in the plate pin hole positioning accuracy when mounting this cylinder.

With Coil Scraper 11 MGG XC35 Standard part number from page 1 With coil scraper Scrapers are used on the piston rod and guide rods (front and rear) to protect the seals by removing frost, welding spatter and chips, etc., that adhere to the moving parts.

Bore size (in) 1.50 2, 2.50 3.25, 4 Standard stroke 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24, 28 How to Order Mounting Bore Stroke NC D A1 XC35 Ex: NCDA1B 150-0400-XC35 With coil scraper Auto switch capable 6-15-33 33 Series NCA1 Accessory Bracket Dimensions Eye Bracket Part no.

Magnet: Built-in, Mounting: MP2, Detachable Rear Clevis, Bore Size: 1 1/2", Stroke: 1", Air Cushion: Both Ends (Air Cushion), Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: with Coil Scraper

Magnet: Built-in, Mounting: MP2, Detachable Rear Clevis, Bore Size: 2 1/2", Stroke: 1", Air Cushion: Both Ends (Air Cushion), Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: with Coil Scraper

Magnet: Built-in, Mounting: MF1, Front Flange, Bore Size: 1 1/2", Stroke: 1", Air Cushion: Both Ends (Air Cushion), Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: with Coil Scraper

Magnet: Built-in, Mounting: MP1, Double Rear Clevis, Bore Size: 4", Stroke: 1", Air Cushion: Both Ends (Air Cushion), Auto Switch: A53--Reed, DC Volt >5<24, LED, Lead Wire or Prewired Connector: 3m, Number: 1 pc., X Option: with Coil Scraper

Retaining Force Of Air Pressure Lock-up 0100 1574 (7000) 1346 (6000) / ~?p>. .-~ --_1 124 (5000) ,/ /. / --/./-.P: 2 ;;; 900 (4000) !

When bank 2 is selected 0 Decimal no. 1 2 3 4 5 6 7 8 9 Bank 2 Bank 3 Bank 4 16 17 18 19 20 BCD 0 0001 0010 0011 0100 0101 0110 0111 1000 1001 11 12 13 14 15 Ex.) 1294.53 is expressed as follows. 0001 0010 1001 0100 0101 0011 6 7 8 9 10 Bank 1 1 2 3 4 5 RS-232C 1 2 3 4 5 6 7 8 9 10 Output terminal This is the interface standard for the serial transmission method, which is standard equipment

When bank 2 is selected Decimal no. 1 2 3 4 5 6 7 8 9 0 BCD 0 0001 0010 0011 0100 0101 0110 0111 1000 1001 16 17 18 19 20 Bank 2 Bank 3 Bank 4 11 12 13 14 15 Ex.) 1294.53 is expressed as follows. 0001 0010 1001 0100 0101 0011 6 7 8 9 10 Bank 1 1 2 3 4 5 RS-232C 1 2 3 4 5 Output terminal 6 7 8 9 10 Preset no.

cm) 40 ~ 140F (5 ~ -60C) 2 ~ 20 inch/sec (50 ~ 500mm/sec) Air Cushion Standard Basic, Foot, Flange, Center Trunnion, Side Tapped Standard Stroke List (in) Bore size Standard Stroke 2, 2.50 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24 3.25, 4 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24, 28 How To Order Oversized Rod/Non-Rotating MOUNTING BORE STROKE X119US NCA1 K Ex: NCDA1KB 200-0100

When bank 2 is selected 0 Decimal no. 1 2 3 4 5 6 7 8 9 Bank 2 Bank 3 Bank 4 16 17 18 19 20 BCD 0 0001 0010 0011 0100 0101 0110 0111 1000 1001 11 12 13 14 15 Ex.) 1294.53 is expressed as follows. 0001 0010 1001 0100 0101 0011 6 7 8 9 10 Bank 1 1 2 3 4 5 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800