(Example) CDNGLN40-100-D 0.5 (Nil) 3 (L) 5 (Z) None (N) DC AC 3 wire (NPN equiv.) 5V C76 IC circuit Yes B53 B54 B64 C73 C80 C73C C80C PLC 100V, 200V Solid state switches Reed switches 12V Grommet Mounting brackets part numbers 200V or less No 100V 12V Yes 2 wire 24V Refer to page 3 for the part numbers of mounting brackets for other than the basic air cylinder.
Electrical entry Type Model Feature D-A80 Grommet D-A80H Connector D-A80C Without indicator light Reed switch Grommet D-C80 Connector D-C80C Grommet With timer D-F7NTL Solid state switch D-F7NTL is also available with pre-wired connector. 2 End Lock Cylinder Series CBJ2 Dimensions Basic With front end lock / CBJ2B16-RN 14.5 0 h8-0.022 10 5 M10 x 1 Piping port 2-M5 x 0.8 20 M5 x 0.8 20.3
D-C76, D-C80 Band Mounted Reed Type Specifications Auto switch/lnternal circuit D-C73 . Respols tire 1 .2ns t Lead wre oilpr@rv nyr,63.4,0.008 in.
D-C76, D-C80 Band Mounted Reed Type Specifications Auto switch/lnternal circuit D-C73 . Respols tire 1 .2ns t Lead wre oilpr@rv nyr,63.4,0.008 in.
Series NCJ2 miniature cylinders available in spring return, spring extend, or double acting all offer stainless steel tubing and stainless steel rods. Available in bore sizes 6, 10, 16mm and stroke lengths from 1/2in. to 8in.. Basic, foot, front flange and double rear clevis mounting options. Auto-switch capable. Other features include non-rotating, double rod, rubber bumpers and a stainless
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø10 (3/8"), Stroke: 100 (1"), Port Location: Perpendicular, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire, 0.5M
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø16 (5/8"), Stroke: 600 (6"), Port Location: Perpendicular, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire, 0.5M, Number: S (1 pc.)
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø16 (5/8"), Stroke: 500 (5"), Port Location: Perpendicular, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire, 0.5M, Number: S (1 pc.)
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø16 (5/8"), Stroke: 300 (3"), Port Location: Perpendicular, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire, 0.5M, Number: S (1 pc.)
Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø16 (5/8"), Stroke: 500 (5"), Port Location: Perpendicular, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire, 0.5M
Magnet: Built-in, Mounting: Rod Flange, Bore: 16mm, Stroke: 45mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Band Mounting, Cushion: -, Series: -
Magnet: Built-in, Mounting: Rod Flange, Bore: 16mm, Stroke: 60mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Band Mounting, Cushion: -, Series: -
Magnet: Built-in, Series: -, Mounting: Basic, Bore Size: 16mm, Stroke: 75mm, Action: Single Acting, Spring Extend, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
Magnet: Built-in Magnet, Series: -, Bore Size: 16mm, Stroke: 150mm, Head Cover Port Location: Perpendicular to Axis, Rod End Bracket: None, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Band Mounting
Magnet: Built-in Magnet, Series: -, Bore Size: 16mm, Stroke: 75mm, Head Cover Port Location: Perpendicular to Axis, Rod End Bracket: None, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Band Mounting
Magnet: Built-in Magnet, Series: -, Bore Size: 10mm, Stroke: 75mm, Head Cover Port Location: Perpendicular to Axis, Rod End Bracket: None, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Band Mounting
Magnet: Built-in Magnet, Series: -, Mounting: Basic, Bore Size: 16mm, Stroke: 100mm, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Band Mounting
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: C80, Lead Wire Length(m): 0.5, The number
Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: C80, Lead Wire Length(m): 3, The number of the switches: 1, Type of
Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 8", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: C80, Lead Wire Length(m): 3, The number of the switches: 4, Type of