Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 03 (3/8), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket)

Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 03 (3/8), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket), Calibration Certificate: A (Calibration Certificate)

Rated Flow Range: 0.5 to 4L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 3/8, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 0.5 to 4L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 3/8, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate, Made to Order: -

Rated Flow Range: 0.5 to 4L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 3/8, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: Bracket, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 0.5 to 4L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 3/8, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: w/o Lead Wire w/M8 Connector, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate, Made

Rated Flow Range: 0.5 to 4L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 3/8, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 0.5 to 4L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 3/8, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 0.5 to 4L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 3/8, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: Calibration Certificate, Made to Order: -

LEFS 25 B 6N 1 20 0 1 DIN 1 6 16 25 25 I/O 32 32 40 40 1.5 m 1 1 3m 3 3m 3 5m 5 5 5m 40 16 25 32 40 16 25 32 ( ( DC24V NPN NPN A A LECP6/LECA6 6N 6N PNP PNP DC24V 6P 6P NPN NPN LECP1 1N * 1N * LECP1 PNP PNP 40 32 25 16 1P * 1P * 40 32 25 16 NPN NPN A A 10 mm 12 mm 16 mm 20mm AN * LECA6 AN * LECA6 PNP PNP B B 5 mm 6 mm 8 mm 10mm AP * AP * 100 mm 100 8m 8m 100 8 8 10m

Z (Example) Y59BZ D-Y7BA is available only as "L". Auto switches marked with a "" symbol are produced upon receipt of order. Note 1) Take note of hysteresis with 2 color indication type switches.

Calculate the load factor for each direction. x = Xc/Lx, y = Yc/Ly, z = Zc/Lz 5. Confirm the total of x, y and z is 1 or less. x + y + z 1 When 1 is exceeded, please consider a reduction of acceleration and work load, or a change of the work load center position and series. Acceleration [mm/s2]: a Work load [kg]: m Work load center position [mm]: Xc/Yc/Zc z y 1. Horizontal 3.

We refer to these products as Z Products. These revolutionary products, whether simple or complex, provide P/A customers with superior performance and availability at a very affordable cost.

Z Y69BZ 2 wire Y59B Y69B Solid state switch 12V Relay PLC Grommet Yes 24V 3 wire (NPN) 3 wire (PNP) Y7NW Y7NWV Solid state auto switches marked with a are manufactured upon receipt of order. 5V 12V Diagnostic indicator (2 color indicator) IC circuit Y7PW Y7PWV Refer to pages 6 to 9 for detailed auto switch specifications.

M Rod end male threads Cushion C Rubber bumper Action D Double acting Applicable auto switches Lead wire length (mm) Auto switch models Electrical entry direction Load voltage Type Detailed specifications Indicator light Electrical entry Special function Wiring (output) 0.5 (Nil) 3 (L) Applicable loads 5 (Z) AC DC Perpendicular In-line Z76 5V IC circuit 3 wire Yes P.9 Z73 12V 100V Grommet

www.smcworld.com 378 Electric Actuator Miniature Rod Type LEPY Series Step Motor (Servo/24 VDC) LEF LEJ LEL LEM LEY LES u Actuator cable length [m] o I/O cable length [m]1, Communication plug i Controller/Driver type1 LEPY LEPS LEPY LEPS Nil Without cable 8 8 Nil Without cable (Without communication plug connector)3 Nil Without controller/driver 6N LECP6 (Step data input type) NPN 6P PNP 1N

Magnetic Holding Power (lbs. force Series NCY2B Cylinder Theoretical Output 06, 410 100 o'15, 025,032, Q40 ^1100 3rooo I s00 I eoo g 7oo i m o 90 80 70 60 50 40 z 3 E .9 !

Magnetic Holding Power (lbs. force Series NCY2B Cylinder Theoretical Output 06, 410 100 o'15, 025,032, Q40 ^1100 3rooo I s00 I eoo g 7oo i m o 90 80 70 60 50 40 z 3 E .9 !

9e c:o c+o coo c+z cse l-cos 'lncludes Rod Packing. Piston Packing, and Tube Gasket (2) Comoact Guide Cytinder: Series MGQ 0120zs,/MGQM'MGQL A Perspective drawing 4-NN Thrcugh NOTE !