As the circulating fluid temperature at this time is 20 oC, "AS.06" starts alarm monitoring at the same time as the operation start. Status (2): The circulating fluid temperature becomes within the set range of "AS.04", and starts "AS.04" alarm monitoring".
As the circulating fluid temperature at this time is 20 oC, "AS.06" starts alarm monitoring at the same time as the operation start. Status (2): The circulating fluid temperature becomes within the set range of "AS.04", and starts "AS.04" alarm monitoring".
VQ1000 (VV5Q13)-Plug-in Unit, Flip Type (F, P, J, L, S kit) . VQ0 (VV5Q04)-Plug Lead Unit, Flip Type (F, P, T, S kit) . VQ1000 (VV5Q14)-Plug Lead Unit, Flip Type (F, P, T, S kit) . VQ2000 (VV5Q24)-Plug Lead Unit, Flip Type (F, P, T, S kit) .
Applicable model 84 84 03 FGD-CV002-04 06 03 FGD-CV003-04 06 03 FGD-CV004-04 06 03 FGD-CV001-04 06 32 32 FGDT/F FGDT/F FGDC/E FGDC/E Note 1) Same as standard product except for cover assembly Note 2) 03, 04, and 06 indicate the relevant port sizes (Rc3/8, 1/2, 3/4).
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature.
LVQ Metric sizes 4 04 06 4 6 N.C.
F A F For the double axis type, this is the cylinders central axis.
CJ1 How to Order CJP Mounting CJ2 Cylinder stroke (mm) B Basic L Axial foot F Rod flange G Head flange C Single clevis D Double clevis U Rod trunnion T Head trunnion E Integrated clevis BZ Boss-cut/Basic JCM Direction of low friction CM2 CM2 F With pressure at head side B With pressure at rod side FZ Boss-cut/Rod flange CM3 UZ Boss-cut/Rod trunnion Made to Order CG1 CM2Q L F 40 150 CG3 40
F A F For the double axis type, this is the cylinders central axis.
10mA load current) 0.8V or less 4V or less Internal voltage drop 100A or less at 24VDC 0.8mA or less at 24VDC Leakage current Operating position .
F A L L L Guide central axis A M1 = F x L M2 = F x L M3 = F x L Note) Displacement of Section A when force acts on Section F CYP15 (M1) CYP15 (M2) CYP15 (M3) 0.05 0.05 0.05 0.04 0.04 0.04 Deflection (mm) Deflection (mm) Deflection (mm) 0.03 0.03 0.03 0.02 0.02 0.02 0.01 0.01 0.01 0.1 0.2 0.3 0 0.1 0.2 0.3 0 0.1 0.2 0.3 0 Moment (Nm) Moment (Nm) Moment (Nm) CYP32 (M1) CYP32 (M2) CYP32 (M3)
F A L L L Guide central axis A M1 = F x L M2 = F x L M3 = F x L Note) Displacement of Section A when force acts on Section F CYP15 (M1) CYP15 (M2) CYP15 (M3) 0.05 0.05 0.05 0.04 0.04 0.04 Deflection (mm) Deflection (mm) Deflection (mm) 0.03 0.03 0.03 0.02 0.02 0.02 0.01 0.01 0.01 0.1 0.2 0.3 0 0.1 0.2 0.3 0 0.1 0.2 0.3 0 Moment (Nm) Moment (Nm) Moment (Nm) CYP32 (M1) CYP32 (M2) CYP32 (M3)
M M H W Y L E 1/8 LQ1H11-F LQ1H12-F LQ1H21-F LQ1H22-F LQ1H23-F LQ1H24-F LQ1H31-F LQ1H32-F LQ1H33-F LQ1H34-F LQ1H35-F LQ1H36-F LQ1H41-F LQ1H42-F LQ1H43-F LQ1H44-F LQ1H51-F LQ1H52-F LQ1H53-F LQ1H54-F LQ1H61-F LQ1H62-F LQ1H63-F LQ1H64-F 4 3 6 4 6 4 10 8 6 10 8 6 12 10 12 10 19 12 19 12 25 19 25 19 11.5 18.5 10 10 26.5 1/8" Class 1 Rc (NPT) Port size 18.5 35 1/8" 16.5 14 14 15 (L) 21.5 36.5
NPT Threads Port Size Symbol 02 03 04 Accessories Symbol Nil B* H* Applicable Body Size 20 30 40 Port Size 1/4 3/8 1/2 Description None Mounting Bracket Panel Mount Nut *Note: Bracket and/or panel mount nut are not assembled and are supplied loose at time of shipment.
Response time (ms) (at 0.5 MPa) Note) Barrier I.S.
specification Nil N F Rc NPT G Nil N Lead wire with connector 3m Without lead wire Port size Applicable models Flow rate (l/min) Port size Symbol 40 100 4 16 03 04 06 10 3/8 1/2 3/4 1 PF2W504, PF2W520 PF2W520, PF2W540 PF2W540, PF2W511 PF2W511 Specifications PF2W504 PF2W520 PF2W540 PF2W511 Model Measured fluid Water Detection type Karman vortex 0.5 to 4l/min 2 to 16l/min 5 to 40l/min 10
AS2001FM-04-X12 Ex.) AS2001FM-04-X21 AQ Note 1) Not particle-free ASV Throttle Valve (Without Check Valve) X214 AK Ex.) AS2001FM-04-X214 VCHC ASR ASQ Needle Valve/Flow Rate Characteristics Note) The flow rate characteristics are representative values.
Clean One-touch fitting (for blow off) 04 06 08 10 12 4 6 8 10 12 01 02 03 04 00 04 06 08 10 12 R 1/8 R 1/4 R 3/8 R 1/2 Thread connection Tubing (rod) connection Model H L T Y U R Male connector, Straight union Union elbow, Male elbow Male branch tee, Union tee Male run tee Male branch, Union "Y" Plug-in reducer Plug Same dia. tubing 4 6 8 10 12 Different dia. tubing (plug-in reducer) Clean
Clean One-touch fitting (for blow off) 04 06 08 10 12 4 6 8 10 12 01 02 03 04 00 04 06 08 10 12 R 1/8 R 1/4 R 3/8 R 1/2 Thread connection Tubing (rod) connection Model H L T Y U R Male connector, Straight union Union elbow, Male elbow Male branch tee, Union tee Male run tee Male branch, Union "Y" Plug-in reducer Plug Same dia. tubing 4 6 8 10 12 Different dia. tubing (plug-in reducer) Clean