SMC Corporation of America
Elite Part Number Search
Search Results "PFM511S-C6-1-N"

side of A port Nil 1 8 01 Rc VFN Nil Rc G NPT NPTF C4 4 cassette P port: Rc 1/8 R port: Rc 1/8 A port: Rc 1/8 F N T Same side of A port S C6 6 cassette Valve stations Type S42 (Solenoids on the same side of A port) 01 1 station 20 20 stations P port: Rc 1/8 R port: Rc 1/8 A port: Rc 1/8 Common SUP/Individual EXH How to Order Type 21: Body ported (A port top ported) Applicable solenoid valve

(800) 526-7661 1/4 NPT Male Thread to Tube 1/4 Male Pipe Thread to Tube not shown not shown 9 16 Hex Typ. 31/32 31/32 3 4 Typ. 1-3/32 1-1/8 1-1/4 9 32 1 1-1/16 44 1/4 B2 1/2 1/4 B2 1/4 B4 1/4 B6 1/4 B3 1/4 B1 1/4 B5 1/4 B8 1/4 B3 1/2 1/4 Male Pipe Straight Manifolds Top View Top View #1 Barb P/N 1/4 B1 x 2 1/4 B1 x 3 1/4 B1 x 4 1/4 B1 x 5 1/4 B1 x 6 1/4 B1 x 7 #2 Barb P/N 1/4

type Type of actuation Nil Rc G NPT NPTF Without sub-plate Nil 4 3 2 position double 2 position single 2 1 1/8 With sub-plate 01 F N T JIS Symbol Body ported 3 position closed center 1/4 With sub-plate 02 3 position exhaust center 2 position single 2 position double 5 3 position pressure center (A) 4 (B) 2 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 3 position exhaust center 3 position

VGA Port size Symbol Body ported Thread type VPA Type of actuation Nil Rc G NPT NPTF Without sub-plate Nil 4 3 2 position double 2 position single 2 1 2 position single 2 position double 1/8 With sub-plate 01 F N T VPA3 2(B) (A)4 2(B) (A)4 3 position closed center 3 position exhaust center (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) 5 3 position pressure center 3 position closed center 3 position

C6 (6 Onetouch fitting) C8 (8 Onetouch fitting) Rc(PT)1/8 C6 (6 One-touch fitting) C8 (8 One-touch fitting) Port size A, B port Rc(PT)1/8 Rc(PT)1/8: 11 (0.6) C6: 8.6 (0.48) C8: 9.9 (0.55) Body ported SYJ7l2l __ __ __ (1) Valve effective area mm2(Cv) Base mounted SYJ7l4l __ 11.9 (0.66) 9.5 (0.53) C6: 8.5 (0.47) C8: 9.7 (0.54) __ Note 1) Value for a single solenoid 2 position valve mounted

(The part numbers are for 1 piece.) !0 ZHP ZHP o ZU i VQD-V Replacement Parts/How to Order o!0 Plate assembly i Pad ZHP1 PL A 1 N ZP3E 80 BM Holder Pad material N NBR S Silicone rubber U Urethane rubber F FKM Size (Applicable pad dia./form) 1 63/80: Flat type, 63: Bellows type 2 80: Bellows type Plate Part number for a set of plate and holder Pad form !

Side 1/4 1/4 1,3,5 (P,EA,EB) Port 1/8 C6 (One-touch fitting for 6) C8 (One-touch fitting for 8) 1/4 Port size 1/4 C6 (One-touch fitting for 6) 4,2 (A,B) Port C10 (One-touch fitting for 10) C8 (One-touch fitting for 8) Manifold base weight W (g) n: Station W = 61n + 101 W = 79n + 127 W = 100n + 151 Note 1) For more than 10 stations (more than 5 stations in case of SS5Y7), supply pressure to

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N02 (NPT1/4), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)]

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N02 (NPT1/4), Piping Entry Direction: L (Bottom), Output Specification: 1 [Analog Output (1 to 5 V)]

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N7 (ø1/4 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)]

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: 02 (Rc1/4), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)]

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: C8 (ø8 (5/16") one-touch fitting), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)]

(MPa): 1, Flow Rate Type: Standard, Operating Temperature Range(°C): -10~60, Operating Humidity Range(%): 35~85, Number of Inputs: 2, Number of Outputs: 1, Analog Voltage Output(V): [DC1-5V] 1-5V, Power Supply Type: DC, Power Supply Voltage(V): [24] 24±10%, Pipe Connection Direction: 2-way, Connecting Tube Diameter: -, Liquid contact parts material: Resin + Metal, Mounting Hole: Presence,

Flow Rate Type: Standard, Operating Temperature Range(°C): -10~60, Operating Humidity Range(%): 35~85, Number of Inputs: 2, Number of Outputs: 1, Analog Voltage Output(V): [DC1-5V] 1-5V, Power Supply Type: DC, Power Supply Voltage(V): [24] 24±10%, Pipe Connection Direction: 2-way, Connecting Tube Diameter: [8] 8(5/16inch), Liquid contact parts material: Resin + Metal, Mounting Hole: Presence

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: Yes, Port Size: NPT1/4, Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: Yes, Port Size: NPT1/4, Piping Entry Direction: Bottom, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: Yes, Port Size: ø1/4 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -

Ejector valve ZYY35LZ-10S-E15C Double solenoid (24 VDC) SY3240-5LZ J ZZY 1 U Single solenoid (24 VDC) SY3140-5LZ Blanking plate assembly SX3000-75-1A Cylinder port size C6 : With 6 One-touch fitting Manifold base (4 stations) ZZYY3-45-04D-C6-J1U With ejector Number of ejectors 1 to 10 Example) ZYY-J3U ZYY35LZ-10S1-E15C ZYY35LZ-10S 2 SET 1 SET 1 SET U side Stations3 2 1 D side 13-8-6 7 Ejector

center SMC 5 3 position pressure center Dual body type (double/3 position) Pilot type Internal pilot External pilot Nil R Manifold SS5Y3-45GD-05U-C6 Rated voltage SS5Y3-45GD-05U-C6 . 1 set (manifold part number) SY3140-5FU . 3 sets (single solenoid part number) SY3245-5FU . 1 set (double solenoid part number) 5 24VDC Manual override Nil Non-locking push type D E Slotted locking type Knob

Single unit 3/4, 1, 1 1/2 0.03 to 1 20, 27, 40 17-2-79 VQ20/30 N.C. Single unit C6 to C12 Pilot operated (For dry air) 0.01 to 0.6 3.4, 4.8 C6 to C12, (3/8) (1) 17-2-89 VV2Q22/32 N.C. Manifold Note 1) All IN ports are 3/8. Note 2) 10 is N.C.