201 241 OUT 402 281 MXS 8 10, 20, 30, 40, 50, 75 16 8 MGG 60 91 121 151 181 211 IN 302 MXS12 10, 20, 30, 40, 50, 75, 100 OUT 628 126 188 251 314 377 440 20 10 MXS16 MGC 10, 20, 30, 40, 50, 75, 100, 125 IN 471 94 141 188 236 283 330 MXS20 10, 20, 30, 40, 50, 75, 100, 125, 150 OUT 982 196 295 393 491 589 687 25 12 MGF MXS25 10, 20, 30, 40, 50, 75, 100, 125, 150 IN 756 151 227 302 378 454 529
25 25 25 25 25 25 51 to 100 37.5 37.5 37.5 37.5 37.5 37.5 101 to 150 50 50 50 50 50 50 201 to 300 100 100 100 100 100 100 301 to 400 125 125 125 125 125 125 401 to 500 150 150 150 150 501 to 600 175 175 601 to 700 200 200 701 to 800 73 81 89 89 101 101 1 to 50 86 94 102 102 114 114 51 to 100 98 106 114 114 126 126 101 to 150 111 119 127 127 139 139 201 to 300 161 169 177 177 189 189 301
134 135 65 75 35 13 16 9 130 9 30 109 75, 100 125, 150 200, 250 300 32 M6 x 1 depth 13 60 118 35 102 106 150 M8 80 134 140 73 16 85 40 16 9 135 129 9 35 40 M8 x 1.25 depth 16 75 50 150 134 134 M8 95 186 170 175 93 105 50 19 19 12 170 9 45 152 50 M10 x 1.5 depth 21 90 56 160 152 140 115 210 200 103 190 115 55 21 12 194 25 11 50 182 M10 Long Stroke Bracket Mounting Stroke Bracket mounting
to 750mm/s C85 0.035J Allowable kinetic energy 10 0.090J 16 CG1 No freezing MB Standard Stroke (mm) C95 Bore size Standard stroke 10 15, 30, 45, 60, 75, 100, 125, 150 CA1 16 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 CS1 Minimum Strokes for Auto Switches Mounting Min. stroke (mm) Mounting Auto switch model Number of switches 2 (same surface) 50 D-C7 D-C8 2 (different surfaces) 15 1 15 D-H7
5 100 5 100 1 10 150 10 150 10 150 10 150 2 15 200 15 200 15 200 15 200 3 20 300 20 300 20 300 20 300 4 25 400 25 400 25 400 25 400 5 30 500 30 500 30 500 30 500 6 35 600 35 600 35 600 35 600 7 40 700 40 700 40 700 40 700 8 45 800 45 800 45 800 45 800 9 50 900 50 900 50 900 50 900 10 55 1000 55 1000 55 1000 55 1000 11 60 1200 60 1200 60 1200 60 1200 12 65 1400 65 1400 70 1400 70 1400 13 70
Pressure setting unit for MPa: 0.01 MPa Pressure setting unit for PSI: 1 PSI series, Other Other series, models models HRSH100/150/200/ HRSH100/150/200/2 250-W-T 50-W-T MPa to to PSI to to *When SE.19 is set to "dI.2", the maximum value becomes 0.7MPa (102 PSI). Setting: Pump operation frequency 6. Press the [SEL] key once.
Therefore, also check the allowable load for the selected conditions. 16 20 25 32 40 50 63 6.0 3.0 2.0 18 7 2.1 10 5.0 3.0 25 10 3 15 8.5 5.0 35 14 4.2 MY1C 30 14 10 49 21 6 60 23 20 68 30 8.2 115 35 35 93 42 11.5 150 50 50 130 60 16 The above values are the maximum allowable values for moment and load.
0 50 100 150 200 160 120 80 40 200 0 0 100 150 200 Load N 1N = 0.2248 lbf Load N 1N = 0.2248 lbf Load N 1N = 0.2248 lbf 20 20 20 Lr=122mm 0.040 0.05 0.10 0.035 MXS20-125 MXS20-150 MXS20-100 MXS20-150 MXS20-75 MXS20-50 MXS20-40 MXS20-30 MXS20-20 MXS20-10 0.04 0.08 MXS20-125 MXS20-150 MXS20-100 MXS2075 MXS2050 MXS2040 MXS20-125 MXS20-100 0.030 Table deflection mm Table deflection mm Table
for 1/4" (Inch size) N3: With One-touch fitting for 5/32" N7: With One-touch fitting for 1/4" N9: With One-touch fitting for 5/16" SX 000-50-3AP PG PH SX 000-50-4AFor 45(N) (Flat ribbon cable) SX 000-50-5ASX 000-50-6AT T1 For 45 (Terminal block) SX 000-50-7A1-6-110 111 Base Mounted Series SX3000/5000 How to Increase Manifold Bases (1) Loosen bolt (a) fixing the manifold base until it begins
65 60 Inrush Frequency (Hz) 50 45 55 50 65 60 50 60 50 60 50 60 50 60 50 60 50 60 9 7 19 16 30 25 11 8 20 18 32 27 VX21 VX21 VX22 VX22 VX23 VX23 Note) The values are for an ambient temperature of 20C and at the rated voltage.
10, 20, 30, 40, 50 75, 100, 125, 150 10, 20, 30, 40, 50, 75, 100 125, 150, 175, 200 Refer to "Made to Order" on page 51 for long strokes (i.e., strokes beyond the standard stroke range).
Hz), 3-phase 200 to 230 VAC (60 Hz) -20 3-phase 200 VAC (50 Hz), 3-phase 200 to 230 VAC (60 Hz) -20 3-phase 200 VAC (50 Hz), 3-phase 200 to 230 VAC (60 Hz) -40 3-phase 380 to 415 VAC (50/60 Hz) -40 3-phase 380 to 415 VAC (50/60 Hz) -40 3-phase 380 to 415 VAC (50/60 Hz) Set temp. range 5 to 35C Set temp. range 5 to 35C Set temp. range 5 to 35C Temp. stability 0.1C Temp. stability 0.1C Temp
Cylinder stroke 50mm 10 6 16 20 25 32 40 40 50 63 80 100 150 300 450 600 750 150 300 450 600 750 4 2.7 (0.15) VQ0 (Metal seal) 4 3.6 (0.2) VQ0001 (Rubber seal) Series VQ1000 Cylinder bore size (mm) Series CA1 Pressure 0.5MPa Load factor 50% Piping length 5m Speed controller: AS3000F-06 (S=6.5mm2) Cylinder stroke 300mm Series CM2 Pressure 0.5MPa Load factor 50% Piping length 5m Speed controller
Mounting bolt C D Mounting Bolt Size for NCQ8B056 to 250(Without Auto Switch) (Inch) Model C D Bolt size Model C D Bolt size NCQ8B056-012 025 037 050 062 075 087 100 125 150 175 200 250 300 350 400 NCQ8B075-012 025 037 050 062 075 087 100 125 150 175 200 250 300 350 400 NCQ8B106-012 025 037 050 062 075 087 100 125 150 175 200 250 300 350 400 NCQ8B150-012 025 037 050 062 075 087 100 125 150
LG1H/ Aluminum body LG1TH/ Stainless steel body LJ1 LG1 LC1 LX LC6D/LC6C Switches 50 10 10 50 Horizontal load 100% Horizontal load 50% 20 10 20 10 Horizontal load 100% Horizontal load 50% Amount of deflection m Amount of deflection m 500 1000 1000 500 200 100 200 100 50 20 50 20 10 10 5 5 Lateral load 100% Lateral load 100% 0.5 1 2 0.5 1 2 Lateral load 50% Lateral load 50% Horizontal empty
150 150 2759 200 200 2760 250 200 2760 325 325 2761 400 325 2761 Stroke (In Inches and Hundredths of Inches) Bore 150 200 250 325 400 Note: Quantity is one piece.
Standard Stroke Bore size (mm) Standard stroke (mm) Manufacturable Note) maximum stroke (mm) 6 300 50, 100, 150, 200 10 500 50, 100, 150, 200, 250, 300 50 100, 150, 200, 250, 300, 350, 400, 450 500, 600, 700, 800, 900, 1000 6000 63 Note) Please contact SMC if it is used by exceeding the maximum stroke length.
100 150 200 250 0 50 100 150 200 250 Supply pressure (kPa) Supply pressure (kPa) Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 0.6 0.4 0.5 mm 0.25 mm 0.5 Detection distance (mm) Detection distance (mm) 0.3 0.4 0.3 0.2 0.15 mm 0.2 0.15 mm 0.1 0.1 0.03 mm 0.01 mm 0 0 0 50 100 150 200 250 0 50 100 150 200 250 Supply
Bore size/Stroke (mm) Data 10 25, 50, 75, 100 16 25, 50, 75, 100, 125, 150, 175, 200 End lock 20 25, 50, 75, 100, 125, 150, 175, 200 25 25, 50, 75, 100, 125, 150, 175, 200 R End lock 32 (25), 50, 75, 100, 125, 150, 175, 200 Nil None Note 1) For (25) stroke, the shock absorber is mounted on a single side of the plate.
to 250 X 50 EPR 20 to 150 X X X The above table covers only general characteristics of subject rubber materials.