Size: 1 (100), Valve Type: 0 (3-port), Seal Material: B (FKM), Pressure Range: 30 (0 to 3MPa), Thread: Rc, Port Size: 10 (3/8, SGH100), Voltage: 5 (24VDC), Electrical Entry: T (Conduit Terminal), Light/Surge Suppressor: Z (Light/Surge Suppressor, Non-polar), Manual Override: Non-locking Push Type, Bracket: B2 (Bracket on Right Side)
Size: 400, Valve Type: N.C., Seal Material: FKM, Pressure Range: 0 to 7 MPa, Thread: Rc, Port Size: 1, SGH400, Pilot Valve: V116, for 7 MPa, Voltage: 24VDC, Electrical Entry: Conduit Terminal, Light/Surge Suppressor: Light/Surge Suppressor, Non-polar, Manual Override: Non-locking Push Type, Bracket: Bracket on Right Side
Size: 100, Valve Type: 3-port Dual Pressure Type, Seal Material: NBR, Pressure Range: 0 to 3MPa, Thread: NPT, Port Size: 3/8, SGH100, Voltage: 24VDC, Electrical Entry: Conduit Terminal, Light/Surge Suppressor: Light/Surge Suppressor, Non-polar, Manual Override: Non-locking Push Type, Bracket: Bracket on Right Side
Size: 100, Valve Type: 3-port Dual Pressure Type, Seal Material: NBR, Pressure Range: 0 to 7MPa, Thread: Rc, Port Size: 3/8, SGH100, Voltage: 24VDC, Electrical Entry: Conduit Terminal, Light/Surge Suppressor: Light/Surge Suppressor, Non-polar, Manual Override: Non-locking Push Type, Bracket: Bracket on Right Side
Size: 400, Valve Type: 3-port, Seal Material: FKM, Pressure Range: 0 to 3MPa, Thread: Rc, Port Size: 1, SGH400, Voltage: 24VDC, Electrical Entry: Conduit Terminal, Light/Surge Suppressor: Light/Surge Suppressor, Non-polar, Manual Override: Non-locking Push Type, Bracket: Bracket on Right Side
Size: 200, Valve Type: 3-port Dual Pressure Type, Seal Material: FKM, Pressure Range: 0 to 7MPa, Thread: Rc, Port Size: 1/2, SGH200, Voltage: 24VDC, Electrical Entry: Conduit Terminal, Light/Surge Suppressor: Light/Surge Suppressor, Non-polar, Manual Override: Non-locking Push Type, Bracket: Bracket on Right Side
Size: 400, Valve Type: 3-port Dual Pressure Type, Seal Material: FKM, Pressure Range: 0 to 7MPa, Thread: Rc, Port Size: 1, SGH400, Voltage: 24VDC, Electrical Entry: Conduit Terminal, Light/Surge Suppressor: Light/Surge Suppressor, Non-polar, Manual Override: Non-locking Push Type, Bracket: Bracket on Right Side
Size: 400, Valve Type: 3-port, Seal Material: FKM, Pressure Range: 0 to 7MPa, Thread: Rc, Port Size: 1, SGH400, Voltage: 24VDC, Electrical Entry: Conduit Terminal, Light/Surge Suppressor: Light/Surge Suppressor, Non-polar, Manual Override: Non-locking Push Type, Bracket: Bracket on Right Side
Model: SGC200, Valve Type: Normally Closed, Seal Material: FKM, Pressure Range: 0 to 1.6 MPa, Thread: Rc, Port Size: 1/2, Pilot Valve: 0.35 W Type, V116, Voltage: 24 VDC, Electrical Entry: Conduit Terminal, Surge Suppressor: With Light and Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Bracket Mounting Position: Bracket on the Right Side, Auto Switch: -, Lead Wire: -, Number
Series SGC coolant valve, with both CE and RoHS accreditation, provides the perfect solution for high speed machining. Due to the SGC's unique scraper, squeeze seal, grease channel and dry bearing construction, the valve's service life will exceed 5 million cycles. The introduction of a built-in magnet allows auto switches to be fitted, enabling confirmation of whether the valve is open
Series SGC coolant valve, with both CE and RoHS accreditation, provides the perfect solution for high speed machining. Due to the SGC's unique scraper, squeeze seal, grease channel and dry bearing construction, the valve's service life will exceed 5 million cycles. The introduction of a built-in magnet allows auto switches to be fitted, enabling confirmation of whether the valve is open
I = m x (a2 + b2) / 12 + m x H2 I = 0.15 x (0.062 + 0.042) / 12 + 0.15 x 0.032 = 0.0002 kgm2 Moment of inertia Kinetic energy 6 Confirm that the loads kinetic energy is within the allowable value. 1/2 x I x 2 = < Allowable energy 1 / 2 x (0.0002) x (2 x ( / 2) / 0.3)2 = = 2 / t (: Terminal angular velocity) 0.01096 J < Allowable energy OK : Rotation angle (rad) t: Rotation time (s) Allowable
A1 (mm) Note 2) Operating range Bore size Mounting patternq A1 Mounting patternw A2 Mounting patterne A3 B1 B2 B3 (mm) 10 15 25 5.5 34 64 22 76 34 76 5 35 70 23 82 35 82 Mounting pattern w B2 A2 5 40.5 99.5 28.5 111.5 40.5 111.5 Note 1) Adjust the auto switch after confirming the operating conditions in the actual setting.
I = m x (a2 + b2) / 12 + m x H2 I = 0.15 x (0.062 + 0.042) / 12 + 0.15 x 0.032 = 0.0002 kgm2 Moment of inertia Kinetic energy 6 Confirm that the loads kinetic energy is within the allowable value. 1/2 x I x 2 = < Allowable energy 1 / 2 x (0.0002) x (2 x ( / 2) / 0.3)2 = = 2 / t (: Terminal angular velocity) 0.01096 J < Allowable energy OK : Rotation angle (rad) t: Rotation time (s) Allowable
I = m x (a2 + b2) / 12 + m x H2 I = 0.15 x (0.062 + 0.042) / 12 + 0.15 x 0.032 = 0.0002 kgm2 Moment of inertia Kinetic energy 6 Confirm that the loads kinetic energy is within the allowable value. 1/2 x I x 2 = < Allowable energy 1 / 2 x (0.0002) x (2 x ( / 2) / 0.3)2 = = 2 / t (: Terminal angular velocity) 0.01096 J < Allowable energy OK : Rotation angle (rad) t: Rotation time (s) Allowable
Parallel I/O Connector: CN5 Wiring diagram LEC6N(NPN) LEC6P(PNP) Power supply 24 VDC for I/O signal CN5 Power supply 24 VDC for I/O signal CN5 A1 A1 COM+ COM+ COM COM A2 A2 A3 A3 IN0 IN0 A4 A4 IN1 IN1 A5 A5 IN2 IN2 A6 A6 IN3 IN3 A7 A7 IN4 IN4 A8 A8 IN5 IN5 A9 A9 SETUP SETUP A10 A10 HOLD HOLD A11 A11 DRIVE DRIVE A12 A12 RESET RESET A13 A13 SVON SVON Load Load B1 B1 OUT0 OUT0 Load Load B2 B2
1 I/O cable length [m]*3 Compatible driver Power supply voltage [V] Size 25 32 40 Nil Without driver A1 LECSA1-S100 to 120 A2 LECSA2-S200 to 230 B1 LECSB1-S100 to 120 B2 LECSB2-S200 to 230 C1 LECSC1-S100 to 120 C2 LECSC2-S200 to 230 S1 LECSS1-S100 to 120 S2 LECSS2-S200 to 230 *3 When Without driver is selected for driver type, only Nil: Without cable can be selected.
L1 L L2 d1 CD MR d2 R1 E2 UB CB 45 51 64 74 94 113 26 28 32 40 50 60 32.5 38 46.5 56.5 72 89 22 25 27 32 36 41 5 5 5 5 5 5 12 15 15 20 20 25 5.5 5.5 6.5 6.5 10 10 30 35 40 45 45 55 10 12 12 16 16 20 9.5 12 12 16 16 20 6.6 6.6 9 9 11 11 6.5 6.5 8.5 8.5 11 12 48 56 64 75 95 115 45 52 60 70 90 110 26 28 32 40 50 60 32 40 50 63 80 100 C85 C76 CG1 Rear Sngle Clevis DS MB MB1 Bore (mm) E B1 H B2
MK/MK2 RSQ/RSG RSH CE1 CE2 ML2B ML1C REA Calculation for Moment of Inertia I: Moment of Inertia (kgm2) m: Load weight (kg) REC qThin bar Position of rotary axis: Vertical to the bar and through the end rThin rectangular plate Position of rotary axis: Vertical to the plate and through the end RHC a22 3 I = m1 + m2 4a12+b2 12 4a22+b2 12 I = m1 + m2 a12 3 MTS CC wThin bar Position of rotary