LOCK Applicable cable Cord O.D.: 3.5 to 7 (Reference) 0.5mm2 2-core and 3-core wires equivalent to JIS C 3306.
DC+COM A(-) C(+) COM B(-) 1N.C.ON 2 ZNR/ 3AB 23 - No.ZB-OM00301 (10ms ) 1 210ms 2 330m/s 4() A-C ON B-C ON N.C. A-C ON OFF 10msec ON 10 A B OFF 50 A B 10 1 50 3 3 24 - No.ZB-OM00301 ZB / / Assy /HNBR Assy //HNBR 25 - No.ZB-OM00301 2 ()() 5kPa () ZFAZFBZFC ON ZB1-VQ110U N.C (0.3 0.4 0.5 0.6) ZB1-VQ110L (0.30.4) ZB1-VQ120U N.C ZB1-VQ110N.C.
Function: 2 (2 Position Double), Pilot: Internal Pilot, Back Pressure Check: None, Voltage: 5 (24VDC), Light & Surge Suppressor: R (Surge Suppressor), Manual Override: Non-locking Push Style, Manifold Block: C (Cassette Base Type 16 Manifold Block), Manifold Wiring: Double, A, B Port: C4 (ø4 One-touch Fitting)
Function: 2 (2 Position Double), Pilot: Internal Pilot, Back Pressure Check: None, Voltage: 5 (24VDC), Light & Surge Suppressor: R (Surge Suppressor), Manual Override: Non-locking Push Style, Manifold Block: C (Cassette Base Type 16 Manifold Block), Manifold Wiring: Double, A, B Port: N7 (1/4" One-touch Fitting)
Function: 2 Position Double, Pilot: Internal Pilot, Back Pressure Check: None, Voltage: 24VDC, Light & Surge Suppressor: Surge Suppressor, Manual Override: Non-locking Push Style, Manifold Block: Cassette Base Type 16 Manifold Block, Manifold Wiring: Double, A, B Port: ø4 One-touch Fitting
Function: 2 Position Double, Pilot: Internal Pilot, Back Pressure Check: None, Voltage: 24VDC, Light & Surge Suppressor: Surge Suppressor, Manual Override: Non-locking Push Style, Manifold Block: Cassette Base Type 16 Manifold Block, Manifold Wiring: Double, A, B Port: 1/4" One-touch Fitting
Function: 3 Position Closed Center, Pilot: Internal Pilot, Back Pressure Check: None, Voltage: 24VDC, Light & Surge Suppressor: Surge Suppressor, Manual Override: Non-locking Push Style, Manifold Block: Cassette Base Type 16 Manifold Block, Manifold Wiring: Double, A, B Port: 1/4" One-touch Fitting
/N.C.), Pilot: Internal Pilot, Voltage: 5 (24VDC), Light & Surge Suppressor: R (Surge Suppressor), Manual Override: Non-locking Push Style, Manifold Block: C (Cassette Base Type 16 Manifold Block), Manifold Wiring: Double, A, B Port: C6 (ø6 One-touch Fitting)
Function: 1 (2 Position Single), Pilot: Internal Pilot, Voltage: 5 (24VDC), Light & Surge Suppressor: R (Surge Suppressor), Manual Override: Non-locking Push Style, Manifold Block: C (Cassette Base Type 16 Manifold Block), Manifold Wiring: Double, A, B Port: C4 (ø4 One-touch Fitting)
Function: 4 (3 Position Exhaust Center), Pilot: Internal Pilot, Voltage: 5 (24VDC), Light & Surge Suppressor: R (Surge Suppressor), Manual Override: Non-locking Push Style, Manifold Block: C (Cassette Base Type 16 Manifold Block), Manifold Wiring: Double, A, B Port: N7 (1/4" One-touch Fitting)
Function: 3 (3 Position Closed Center), Pilot: Internal Pilot, Voltage: 5 (24VDC), Light & Surge Suppressor: R (Surge Suppressor), Manual Override: Non-locking Push Style, Manifold Block: C (Cassette Base Type 16 Manifold Block), Manifold Wiring: Double, A, B Port: C6 (ø6 One-touch Fitting)
Function: 4 Position Dual 3 Port N.C./N.C., Pilot: Internal Pilot, Voltage: 24VDC, Light & Surge Suppressor: Surge Suppressor, Manual Override: Non-locking Push Style, Manifold Block: Cassette Base Type 16 Manifold Block, Manifold Wiring: Double, A, B Port: ø6 One-touch Fitting
Function: 2 Position Single, Pilot: Internal Pilot, Voltage: 24VDC, Light & Surge Suppressor: Surge Suppressor, Manual Override: Non-locking Push Style, Manifold Block: Cassette Base Type 16 Manifold Block, Manifold Wiring: Double, A, B Port: ø4 One-touch Fitting
Function: 3 Position Exhaust Center, Pilot: Internal Pilot, Voltage: 24VDC, Light & Surge Suppressor: Surge Suppressor, Manual Override: Non-locking Push Style, Manifold Block: Cassette Base Type 16 Manifold Block, Manifold Wiring: Double, A, B Port: 1/4" One-touch Fitting
Function: 3 Position Closed Center, Pilot: Internal Pilot, Voltage: 24VDC, Light & Surge Suppressor: Surge Suppressor, Manual Override: Non-locking Push Style, Manifold Block: Cassette Base Type 16 Manifold Block, Manifold Wiring: Double, A, B Port: ø6 One-touch Fitting
Function: 3 (3 Position Closed Center), Pilot: Internal Pilot, Back Pressure Check: None, Voltage: 5 (24VDC), Light & Surge Suppressor: R (Surge Suppressor), Manual Override: Non-locking Push Style, Manifold Block: C (Cassette Base Type 16 Manifold Block), Manifold Wiring: Double, A, B Port: N7 (1/4" One-touch Fitting)
OFF OFF OFF OFF P1 n1 P2 P1 n2 n1 (Standard: Factory setting) (Reversed) (Standard: Factory setting) (Reversed) Press the SET button to set the mode and proceed to the output type setting. 16-2-6 7 Series ZSE30/ISE30 High Precision, 2-color Display Digital Pressure Switch Pressure setting Auto preset setting Manual setting Press the SET button in the measuring mode to display the set value
Function: 1 (2 Position Single), Pilot: Internal Pilot, Back Pressure Check: None, Voltage: 5 (24VDC), Light & Surge Suppressor: U (Light & Surge Suppressor), Manual Override: D (Slotted Locking Type), Manifold Block: C (Cassette Base Type 16 Manifold Block), Manifold Wiring: Double, A, B Port: C4 (ø4 One-touch Fitting)
Function: 1 (2 Position Single), Pilot: Internal Pilot, Back Pressure Check: None, Voltage: 5 (24VDC), Light & Surge Suppressor: U (Light & Surge Suppressor), Manual Override: D (Slotted Locking Type), Manifold Block: C (Cassette Base Type 16 Manifold Block), Manifold Wiring: Double, A, B Port: N7 (1/4" One-touch Fitting)