D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).

D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).

: 629 V DC Current ratings: Target on (LED off) <1.0 mA Target off (LED on) >3.0 mA Must use intrinsically safe repeater barrier.

Fixed SI unit Note) Nil N F Rc NPT G 3m lead wire with connector Without lead wire Nil N Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l Port size Output specification Applicable models Flow rate (l/min) Port size Applicable models Output specification Symbol Symbol 100 200 500 50 10 PF2A710/PF2A750 PF2A711/PF2A721, PF2A751 27 NPN open collector 2 outputs 01 02 03 04

Fixed SI unit Note) Nil N F Rc NPT G 3m lead wire with connector Without lead wire Nil N Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l Port size Output specification Applicable models Flow rate (l/min) Port size Applicable models Output specification Symbol Symbol 100 200 500 50 10 PF2A710/PF2A750 PF2A711/PF2A721, PF2A751 27 NPN open collector 2 outputs 01 02 03 04

Auto switch type D-A3, A4 D-G3, K3 D-B5, B6 D-G5, K5 D-A5, A6 D-F5, J5 Cylinder bore size (mm) Bore size (mm) Standard stroke (mm) Long stroke (mm) Model 1800 (1401 or more with tie-rod reinforcing ring) Note 2) 32 25 to 800 32 40 50 63 80 100 32 40 50 63 80 100 32 40 50 63 80 100 BA-32 BA-04 BA-05 BA-06 BA-08 BA-10 BAF-32 BAF-04 BAF-05 BAF-06 BAF-08 BAF-10 BGS1-032 BH2-040 BH2-050 BA-06

Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more.

-X465 0.1 to 1 Set pressure range (MPa) Desolution of setting and display (MPa) Power supply voltage Specifications AU 0.001 Class 10 With M5 fitting (Applicable tubing O.D. 6) Pressure switch Cleanliness Breather port 12 to 24 VDC 10%, Ripple (p-p) 10% or less (With reverse connection protection) 45 mA or less (but 70 mA or less at current output) AF IR1000/2000: With M5 fitting (Applicable

Note 3) Install a circuit breaker with sensitivity of 30 mA. Note 4) IDF3D to 8D-4/6 are only for frequency of 50Hz. Note 5) Spare part for auto drain INA-20-41-04 is AD44x445.

Compact Pressure Switch Specifications (For further information, refer to Best Pneumatics No. 8) IS10-01 Model 0.1 to 0.4 MPa Set pressure range (OFF) 0.08 MPa Hysteresis 1a Contact point construction 2 VA AC, 2 W DC Max. contact point capacity 12 V 48 V 100 V Voltage (AC, DC) 24 V 50 mA 40 mA 20 mA Max. current 50 mA Symbol 2 1 AMR4000 AMR3000 L AMR5100 686 Regulator with Mist Separator

For details, please contact SMC. 3-11-17 18 Manifold Specifications Standard Specifications ISO Size 1 ISO Size 2 ISO Size 1 Maniflod block size VSR/S8-6 VSR/S8-8 VSR/S8-6 Applicable solenoid valve 1 to 10 Number of stations 1/4, 3/8, 1/2, 3/4, 1 A, B port Port size 1/4, 3/8, 1/2, 3/4, 1 P , EA, PB port VV82-P-03/04/06 VV81-P-02/03/04 Individual SUP spacer VV82-R-03/04/06 VV81-R-02/03/04

IS1000-01 Model 0.1 to 0.4 MPa Set pressure range (OFF) 0.08 MPa Differential 1a Contact point construction 2 VA AC, 2 W DC Max. contact point capacity 12 V 48 V 100 V 24 V Voltage (AC, DC) 50 mA 40 mA 20 mA 50 mA Max. current 1.2 ms Operating time 30 G Shock resistance JIS Symbol AMR5100 AMR4000 AMR3000 14-7-1 2 Series AMR3000 to 6000 How to Order E3 03 R S AMR 4 0 00 Adapter Assembly (Part

The float type auto drain used in the standard air dryer is replaced with a heavy-duty auto drain (ADH4000-04). * The IDF100F to 150F, 190D, 240D standard types are equipped with a heavy-duty auto drain.

5 mA), Holding 1.0 VA (5 mA) 200 VAC Inrush 1.1 VA (5 mA), Holding 1.1 VA (5 mA) 220 VAC Note 1) Use dry air to prevent condensation when operating at low temperatures.

5 mA), Holding 1.0 VA (5 mA) 200 VAC Inrush 1.1 VA (5 mA), Holding 1.1 VA (5 mA) 220 VAC Note 1) Use dry air to prevent condensation when operating at low temperatures.

Current consumption Note 2) Max. 100 mA Max. 65 mA SQ Input/output specifications Number of inputs 8 4 VQ0 Number of outputs 8 4 24 VDC 10% Valve supply voltage VQ4 Possible supply current Note 3) Max. 240 mA Max. 120 mA VQ5 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

-LLL (Lead wire length) 148.3 Insulator: Red (+) Insulator: Black () 0.3 mm2 4.1 5.9 51.2 03 04 Terminal type (TT) 53-SY9140-TTMax. 10 L (Lead wire length) 165.1 Lead wire marking No. 1 (+), No. 2 () 0.75 mm2 48.5 29 Base Mounted Series 53-SY5000/7000/9000 Dimensions: 53-SY9000 2-position double L-type plug connector (L) 53-SY9240-L03 04 29 30 17.5 106 86.5 51.2 2 x 5.4 (For mounting) 25

(Option ) Multi-connector Socket side only Plug side only DMK6-23 DMK6S-23 DMK6P-23 6 DMK-C-6 DMK6-04 DMK6S-04 DMK6P-04 DMK12-23 DMK12S-23 DMK12P-23 12 DMK-C-12 DMK12-04 DMK12S-04 DMK12P-04 Specifications Applicable tubing materials Nylon, Soft nylon, Polyurethane Applicable tubing O.D.

The load ratio is obtained by the following formula: ((Load mass x 9.8)/Theoretical output) x 100% Conditions MB, CA2 series CS1, CS2 series Series Condition 10A x 1 m SGP (Steel pipe) dia. x Length VQ4100--03 VQ4101--03 AS420-03 Speed controller AN30-03 Silencer 10A x 1 m SGP (Steel pipe) dia. x Length VQ5100--04 VQ5101--04 AS420-04 Speed controller AN40-04 Silencer 448 INDEX Page 446 Base