, C4, C6, M5 C3: 3.2 One-touch fitting C4: 4 One-touch fitting C6: 6 One-touch fitting M5: M5 thread (7.5) 20.5 2-C8 1(P) port 34 P = 10.5 (mm) Formulas: L1 = 10.5n + 45, L2 = 10.5n + 167.5 (for 1 input block.
Note 3) Note 4) Cylinder port size Port size Symbol C2 C3 C4 CM N1 N3 NM With 2 One-touch fitting With 3.2 One-touch fitting With 4 One-touch fitting Mixed sizes and with port plug Note) Note 1) When two or more symbols are specified, indicate them alphabetically.
, C4, M5 C3: 3.2 One-touch fitting assembly C4: 4 One-touch fitting assembly M5: M5 thread 2n x C3, C4, M5 C3: 3.2 One-touch fitting assembly C4: 4 One-touch fitting assembly M5: M5 thread 45.5 2.5 10.5 (5) Dimensions Formula L1 = 11n + 20 n: Station (Maximum 20 stations) 21.5 n L 1 2 3 4 5 6 7 8 9 10 L1 31 42 53 64 75 86 97 108 119 130 L2 50 62.5 75 87.5 100 112.5 125 125 137.5 150 L3 60.5
, C4, C6, M5 C3: One-touch fitting for 3.2 C4: One-touch fitting for 4 C6: One-touch fitting for 6 M5: M5 threads Broken lines indicate DIN rail mount type [-D] and connector top entry [-JU].
Metric C3 With 3.2 One-touch fitting C4 With 4 One-touch fitting CM Mixed sizes and with port plug Note) N1 With 1/8" One-touch fitting Inch N3 With 5/32" One-touch fitting NM Mixed sizes and with port plug Note) Note) Indicate the sizes on the manifold specification sheet in the case of CM and NM.
/N.O.) u Coil type C2 C3 C4 C6 C8 Standard With power saving circuit (Continuous duty type) Nil T P P P Be sure to select the power saving circuit type when a valve is continuously energized for long periods of time. Note the specified energizing time when power saving circuit is selected.
Output data Offset Meaning MSB LSB MSB LSB (INT) 15 8 7 0 D4 #D3 #D2 #D1 #C4 #C3 #C2 #C1 #B4 #B3 #B2 #B1 #A4 #A3 #A2 #A1 Slave 8 connection diagnosis 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 In the figure above, #A1 to #A3 are slaves for which the connection is diagnosed. In this case, #A3 slave is not connected, and a diagnostic error is generated.
Vacuum release ON OFF Combination Symbol : K3 Combination Symbol : C3 Feature: Operation can be controlled by an external pilot valve.
Correction Factor C2 for Ambient Air Relative Humidity Vc: Actuator volume (mm3) D : Bore size (mm) s : Stroke (mm) Temperature Relative humidity Correction factor C2 Vc = D2s 4 25C 40C 10C 0.2 0.4 0.6 20% Fig. 2 Piping Volume Chart 0.5 1.0 1.3 40% 140 1.0 1.7 2.8 60% 2.1 4.0 5.9 75% 120 6 tube Correction Factor C3 for Supply Pressure Supply pressure (MPa) Correction factor C3 10 Tube volume
OFF ON OFF Combination Symbol: K3 Combination Symbol: C3 Feature: Operation can be controlled by an external pilot valve.
OFF ON OFF Combination Symbol: K3 Combination Symbol: C3 Feature: Operation can be controlled by an external pilot valve.
Applicable tubing O.D. 3.2 Applicable tubing O.D. 4 Applicable tubing O.D. 6 M5 female thread Straight VVQ1000-50A-C3 VVQ1000-50A-C4 VVQ1000-50A-C6 VVQ1000-50A-M5 Elbow VVQ1000-F1-LC3 VVQ1000-F1-LC4 08 8 stations Note) 2 pcs. are included in one set. 26 Series ZQ Specific Product Precautions Be sure to read before handling.
D-M9AL Bore size (mm) D A B C 6 10 15 20 25 32 19.5 0.5 7.5 11.5 A C 29.5 3 17.5 9 35.5 10 23.5 2 Electrical entry direction: Inward Electrical entry direction: Outward 43 13 31 5 44 15 32 7 53 15.5 41 7.5 Auto switch mounting dimensions (mm) CXSJ6,10 C3 10 Bore size B1 Symbol Auto switch model C2 D2 6 1 1 2 5.5 4 8 6 D1 D-A9 D-M9, D-M9W D-M9AL A1 B1 B1 C1, D1 C2, C3, D2 C1, D1 C2, C3, D2
Seal type allows selection of metal seals or rubber seals Type of actuation A, B port size 2 position 3 position 4 position One-touch fitting Effective area mm (Cv factor) Single/Double Double (Latching/ Double solenoid) Pressure center Exhaust center Series Closed center C3 C4 C8 C6 Dual 3 port valve (3.2) (4) (8) (6) Single SQ130 Metal seal SQ131 Rubber seal SQ230 Metal seal SQ231 Rubber
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard, Valve Type: 3-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Closed, Pipe Port Type: One-Touch Plumbing, Port Size: -, Connecting Tube Diameter: Ø3.2, Pressure Rating(MPa): 0.1 to 0.7, Driving
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard, Valve Type: 3-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Closed, Pipe Port Type: One-Touch Plumbing, Port Size: -, Connecting Tube Diameter: Ø3.2, Pressure Rating(MPa): 0.1 to 0.7, Driving
Function: Standard (0.35W DC, AC), Coil Voltage: 5 (24VDC), Lead Wire: MO (M Plug w/o Connector), Manual Override: Non-locking Push Style, Port Size: C3 (ø3.2 One-touch Fitting), Model: PR (Single Unit Type), Option: None, CE Compliant: Q (CE Marked)
Function: Standard (0.35W DC, AC), Coil Voltage: 5 (24VDC), Lead Wire: L (L Plug Connector w/Lead Wire 0.3m), Manual Override: Non-locking Push Style, Port Size: C3 (ø3.2 One-touch Fitting), Model: PR (Single Unit Type), Option: None, CE Compliant: Q (CE Marked)
Brown 1 32 Yellow/Green White Black 2 C2 Green 14 Blue [G5] Black (CN2) 16 Blue 3 PS2 Orange C4 1 Red 2 Refrigerant low pressure Black Yellow 3 EV1 Brown Black Black Black 17 1 Blue 4 7 8 9 2 Blue 2 21 TH In the device Green 5 Blue 23 3 PS3 Outside the device /Green [3] [C] [2] [4] Yellow (CN3) Black Brown Blue DI sensor (CN5) 2/3 White 1 1 Brown Brown 20 Yellow 2 2 Black Blue 22 PM Orange C3