capacity = Considering a safety factor of 20%, 7.0 [kW] x 1.2 = 8.4 [kW] HED V After 15 minutes, cool 32C down to 20C.
JIS symbol 1/8, 5/32 3/16, 1/4 3/8 5/16 3/16, 1/4 1/4 3/16 1/4, 5/16 1/2 Inch sizes 3/8 5/32 Flow rate l/min (ANR) {Nl/min} 920 660 230 420 1390 290 460 1050 100 130 Controlled (Free) Effective area mm flow 14 10 3.5 6.5 21 4.5 7 16 2 1.5 1l/min=0.035SCFM 18mm2=1Cv Note 1) Flow rate values are at a pressure of 0.5MPa (72.5psi) and temperature of 20C (68F).
Low temperature operation 1) The valve can be used in an ambient temperature of between 10 to 20C.
Flow rate conversion NO OFF n-2 n-1 High flow rate Basic state: 0C, 101.3kPa Standard state: 20C, 101.3kPa, 65%RH (ANR) Switchable between these states.
Flow rate conversion PF2 NO OFF n-2 n-1 High flow rate Basic state: 0C, 101.3 kPa Standard state: 20C, 101.3 kPa, 65%RH (ANR) Switchable between these states.
M km, 20C 5m VVZS3000-21A-3 x 24AWG * For other commercial connectors, use a 25-pole female connector made in conformity with MIL-C-24308.
(Variation: 10%) Note 2) The value at ambient temperature of 20C and when the rated voltage is applied. The value depends on the ambient environment. This is for reference. Note 1) The value at ambient temperature of 20C and when the rated voltage is applied.
1048576 p/rev) 25APower consumption [W] Note 6) Horizontal 45 65 210 Vertical 145 175 230 LEC Standby power consumption when operating [W] Note 7) Horizontal 2 2 2 Vertical 8 8 18 LEC S Max. instantaneous power consumption [W] Note 8) 445 725 1275 Type Note 9) Non-magnetizing lock Lock unit specifications LEC SS-T Holding force [N] 78 131 255 131 197 385 220 330 660 Power consumption at 20C
drain Float type (Normally closed) Float type (Normally open) Refrigerant R407C (HFC) IDF D Port size Rc3/8 Rc1/2 Rc3/4 Rc1 Weight [kg] 16 17 18 22 23 27 28 46 Coating color Body panel: White 1 Base: Gray 2 Applicable air compressor output [kW] (Reference) For screw type 0.75 1.5 2.2 3.7 5.5 7.5 11 15 Refrigerant R134a (HFC) IDU E *1 Air flow capacity under the standard condition (ANR) [20C
[Example of setting] Circulating fluid SP: 20C (1) High Temp. CH1 circulating fluid temperature rise (AL10): 22C (2) Low Temp.
Note) l/min (ANR) is for reference conditions of 20C, 1 ATM and 65% relative humidity. Features 3 Model Selection Data A Correction factor for temperature/Series IDU Inlet air temp.
Specifications Grade 1 Note 1) Particulate generation grade Air, Nitrogen gas, Water (pure water) Note 2) Fluid 1MPa Note 3) Maximum operating pressure (20C) 100kPa Operating vacuum pressure Caution 3MPa Proof pressure (20C) 20C to 80C Ambient and fluid temperature Series KP is a line of special One-touch fittings for use in clean room blowing and washing lines.
Lead wire length 0 1 2 0.6 m 1.5 m 3.0 m Electrical characteristics Item Characteristic Sheath Colour: Urban white Conductor resistance /km, 20C 65 or less Withstand pressure V, 1 minute, AC 1000 Polarity Terminal no. Lead wire colour Dot marking Insulation resistance M/km, 20C 5 or more 1 () (+) Black None SOL. A 14 () (+) Yellow Black Station 1 SOL.
Insulation resistance M/km, 20C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 5 or more Note) The minimum bending radius of the D-sub connector cables is 20 mm.
Flow at 20C, atmospheric pressure, and 65% of the relative humidity The maximum flow capacity varies depending on the inlet pressure.
(Coil temperature : 20C, at rated voltage and without surge voltage suppressor) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
Note 2) Safety allowance x3 at 20C Note 3) To calculate flow factor for longer lengths of tube divide factor for 1 metre by actual length in meters.
Flow rate conversion NO OFF n-2 n-1 High flow rate Basic state: 0C, 101.3kPa Standard state: 20C, 101.3kPa, 65%RH (ANR) Switchable between these states.
Note 2) Flow rate display can be switched between the basic condition of 0C, 101.3 kPa and the standard condition (ANR) of 20C, 101.3 kPa, and 65% RH. Note 3) Without lead wire. Note 4) Accumulated flow rate is reset when the power supply turns OFF. Note 5) Switch output and accumulated pulse output can be selected during initial setting.