SMC Corporation of America
Elite Part Number Search
Search Results "ZK2P00K5CLA-06-BK"

Accepts nylon and urethane tubes, Applicable for both vacuum and positive pressure applications, Release collar allows easy removal of tubing without damaging the tube, Maximum vacuum pressure of 1.0MPa, FITTING, MALE RUN TEE *LQA, CONNECTORS, KQ2 FITTING, BK, KQ2 1/8, .04409 lb

This is a legacy product, and replaced byZK2B15R5CLA-07-BK VACUUM EJECTOR. Vacuum Ejector. 99 lb. M18.

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: T (Pressure Sensor / -100 to 100 kPa / Analogue Output 1 to 5 V), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual

System/Body: Ejector System, Single Unit, Port Exhaust, Nozzle Size: Ejector System, ø1.5 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum w/Energy Saving Function, 100 to -100, PNP 1 Output, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: w/Lead Wire for Switch

System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø1.5 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Pressure Sensor, 0 to -101, Analog Output 1 to 5 V, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Metric Size, ø6 One-touch Fitting, Optional

System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø0.7 Nominal Nozzle Size, Valves: Supply Valve; Self-holding Release Valve Linked, Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Pressure Sensor, 0 to -101, Analog Output 1 to 5 V, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Metric Size,

System/Body: Vacuum Pump System, Single Unit, Nozzle Size: Vacuum Pump System, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Pressure Sensor, 0 to -101, Analog Output 1 to 5 V, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Metric Size, ø6 One-touch Fitting, Optional Specs. 1: B [One Bracket for Mounting

System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø1.5 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Metric

System/Body: Ejector System, Single Unit, Port Exhaust, Nozzle Size: Ejector System, ø0.7 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum w/Energy Saving Function, 100 to -100, NPN 1 Output, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: w/Lead Wire for Switch

System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø1.2 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum w/Energy Saving Function, 100 to -100, NPN 1 Output, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: w/Lead Wire for Switch

System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø1.2 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum w/Energy Saving Function, 100 to -100, PNP 1 Output, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: w/Lead Wire for Switch

System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø0.7 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum w/Energy Saving Function, 100 to -100, NPN 1 Output, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: w/Lead Wire for Switch

System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø1.0 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: w/o Pressure Sensor, Digital Pressure Switch for Vacuum, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Metric Size, ø6 One-touch Fitting, Optional

System/Body: Ejector System, Single Unit, Port Exhaust, Nozzle Size: Ejector System, ø1.5 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Metric Size

System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø1.0 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, SI Unit Only, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Metric Size, ø6 One-touch

System/Body: Vacuum Pump System, Single Unit, Nozzle Size: Vacuum Pump System, Valves: Supply Valve; Self-holding Release Valve Linked, Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, NPN 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Metric Size,

System/Body: Vacuum Pump System, Single Unit, Nozzle Size: Vacuum Pump System, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, NPN 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Metric Size, ø6 One-touch Fitting, Optional

System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø1.5 Nominal Nozzle Size, Valves: Supply Valve; Self-holding Release Valve Linked, Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector