60 44 18 45 25 9 14 17.5 M8 x 1.25 18 16 20 M14 x 1.5 30 1/4 17 10 77 44 95 66 50 25 9 73 73 53 20 50 28 11 17 17 M10 x 1.5 20 22 22 M16 x 1.5 30 3/8 19 10 95 53 115 73 63 28 8 80 80 60 22.4 55 30 11 17 17 M10 x 1.5 22 20 25 M18 x 1.5 30 3/8 21 12 102 60 122 80 80 32 8 100 100 75 28 65 32 13 22 20 M12 x 1.75 26 26 29 M22 x 1.5 35 1/2 26 12 130 75 155 90 100 38 6.5 118 118 90 35.5 80 35 13
D 4 4 6 6 E 60 90 90 90 F 30 60 60 60 G (50) (50) 100 100 Model LXFH5BC-25 LXFH5BC-50 LXFH5BC-75 LXFH5BC-100 Positioning Time Guide (for Horizontal Mount) For transfer load of 0kg For transfer load of 2kg Positioning time (sec) Positioning time (sec) Positioning distance (mm) Positioning distance (mm) 100 50 10 1 100 50 10 1 10 10 10.1 5.1 1.1 0.2 10.1 5.1 1.1 0.2 Speed (mm/s) Speed (mm/s
[Hz] PB34 VRF12B 1 60 [Hz] PB35 VRF13B 1 0.15 PB36 VRF14B 1 0.15 PB56 VRF21B 2 30 [Hz] PB57 VRF22B 2 30 [Hz] PB58 VRF23B 2 0.05 PB59 VRF24B 2 0.05 7 18 7.
(30 10-3) = 2000 [pulses/s) Acceleration time: 60 1500 = 40 [ms] Deceleration time: 60 1000 = 60 [ms] [Calculation example: Target position 2] Travel distance: 6 (30 10-6) = 200 [pulses] (in the reverse direction) Travel speed: 60 (30 10-3) = 2000 [pulses/s] Acceleration time: 60 1500 = 40 [ms] Deceleration time: 60 1000 = 60 [ms] 61 - Step Data setting example Thrust Load mass
) 54.5 40 55.0 50 Set point 60 55.5 70 56.0 80 56.5 90 100 0 20 40 60 80 100 120 57.0 100 95 90 85 80 75 70 65 60 Flow rate (l/min (ANR)) VAC side pressure (kPa) IRV3000 IRV3000 0 53.0 10 53.5 20 54.0 SET side pressure (kPa) 30 Set pressure (kPa) 54.5 40 55.0 50 Set point 60 55.5 70 56.0 80 56.5 90 57.0 100 95 90 85 80 75 70 65 60 100 0 20 40 60 80 100 120 140 160 VAC side pressure (kPa)
Refer to page 16-11-10. 16-11-28 25 Series PF2W Digital Flow Switch, High Temperature Fluid Type For Water Dimensions: Integrated Display Type for Water Internal circuit and wiring example to are terminal numbers. 74 120 Brown 1.6 23 60 Load 1 OUT1 Main circuit 4 Load Black OUT2 2 ZSE ISE 12 to 24 VDC FLOW SWITCH + U P White 3 SET 60 50 34 Blue PSE OUT2 OUT1 PF2W7T--27(-M) DOWN FOR WATER
Use 2 port valve VNH33. 4.2-33 VNH Dimensions Dimensions (mm) Model Main port 2 port 3 port Pilot port H I A C B D E F G 3 8 3 8 Rc(PT) 1 8 2-Rc(PT) 2-Rc 3-Rc(PT) 3-Rc 50 60 79 90 77 95.5 111 119 60 80 100 115 235.5 265 300 319.5 60 77 96 113 46 60 76 85 34 40 50 60 24 36 41 50 135 164.5 200 219 VNH1 -10A VNH2 -15A VNH3 -20A VNH4 -25A A B A B A B A B 1 2 3-Rc 3 4 3-Rc1 Rc1 4 Rc1 4 Rc1 8 1
75 20 20, 25, 32 25 22 19.5 40 32 13 10 17 10.5 10 45 4 60 75 26 32 22 19.5 40 32 13 12 17 10.5 11 45 4 60 75 26 40 24 21 52 41 16 14 22 13.5 12.5 50 5 66 36 82 32 MM N NA NN P S Z ZZ H1 H2 I K KA Bore (mm) 20 30 M20 x 1.5 1/8 37 200 146 M8 x 1.25 20 5 8 33.5 5 6 25 34.5 M26 x 1.5 1/8 41 204 146 M10 x 1.25 20 6 8 37.5 5.5 8 32 42.5 M26 x 1.5 1/8 41 217 159 M10 x 1.25 22 6 8 46.5 5.5 10
TF G 1/8 G 1/8 G 1/8 G 1/4 G 1/4 G 1/4 TN NPT 1/8 NPT 1/8 NPT 1/8 NPT 1/4 NPT 1/4 NPT 1/4 Nil M3 x 0.5 M5 x 0.8 M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/4 Rc 1/4 Rc 1/4 CY3B6 CY3B10 CY3B15 CY3B20 CY3B25 CY3B32 CY3B40 CY3B50 CY3B63 25 30 35 50 50 50 60 60 70 10 16 19 25 30 40 40 60 70 16 16 78 81 103 132 137 156 182 180 192 d CYP C H B H 4 4 8 8 10 B 8 14 26 32 41 C 9.2 16.2 30 37 47.3 d M6 x 1.0
75 20 20, 25, 32 25 22 19.5 40 32 13 10 17 10.5 10 45 4 60 75 26 32 22 19.5 40 32 13 12 17 10.5 11 45 4 60 75 26 40 24 21 52 41 16 14 22 13.5 12.5 50 5 66 36 82 32 MM N NA NN P S Z ZZ H1 H2 I K KA Bore (mm) 20 30 M20 x 1.5 1/8 37 200 146 M8 x 1.25 20 5 8 33.5 5 6 25 34.5 M26 x 1.5 1/8 41 204 146 M10 x 1.25 20 6 8 37.5 5.5 8 32 42.5 M26 x 1.5 1/8 41 217 159 M10 x 1.25 22 6 8 46.5 5.5 10
0 CE-compliant u Electrical entry y Rated voltage i Light/surge voltage suppressor CE-compliant 1 100 VAC, 50/60 Hz 2 200 VAC, 50/60 Hz 3 110 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5 24 VDC 6 12 VDC Nil Q CE-compliant Nil None S With surge voltage suppressor Z With light/surge voltage suppressor G Grommet (Lead wire length 300 mm) H Grommet (Lead wire length 600 mm) L L type plug connector
Hz) 200 VAC (50/60 Hz) 24 VDC Other Air operated For the one without combined valve (0), solenoid valve does not come with.
51 43 34 26 17 85 IN 201 181 161 141 121 101 80 60 40 201 OUT 16 8 151 136 121 106 91 76 60 45 30 151 IN Bore size (mm) Mounting bracket part no.
80 Load (N) 20 40 60 80 Load (N) 20 40 60 100 Load (N) 12 12 12 L = 100 mm L = 100 mm L = 100 mm MXP12-15 MXP12-25 MXP12-15 MXP12-25 0.05 Table displacement amount (mm) Table displacement amount (mm) Table displacement amount (mm) 0.04 0.08 MXP12-15 MXP12-25 MXP12-15 MXP12-25 MXP12-15 MXP12-25 MXP12-15 MXP12-25 0.04 0.03 0.06 0.03 0.04 0.02 0.02 0.01 0.02 0.01 0 50 100 150 Load (N) 0 50
60 60 71.5 71.5 90.5 110 110 123 165 0.5 0.5 0.5 0.75 0.75 0.75 1 1 1.25 2 2 2 3 1 1.5 1 1.25 1.5 1.75 1.5 2 2.5 3 1.5 2 2 8 9 9 13 13 13 15 15 18 24 24 24 42 8 10 10 12 12 12 16 16 20 24 27 27 33 30.5 34 34 38 38 38 44.5 44.5 57.5 68 68 77 99 1146 Floating Joint: Standard Type JA Series Flange Type: JAF20 to JAF160 JAF20 to 40 x Center of sphere J J R JAF50 to 160 Center of sphere x R
Pressure 0.7MPa 120 180 0.6MPa 0.6MPa 100 Gripping force N Gripping force N 150 0.5MPa 0.5MPa 80 120 0.4MPa 0.4MPa 60 90 0.3MPa 0.3MPa 40 0.2MPa 60 0.2MPa 20 30 100 0 80 60 40 20 80 60 40 20 0 100 Gripping point L mm Gripping point L mm 12-3-5 6 Series MHF2 Model Selection Effective Gripping Force: Series MHF2 Step 2 External Gripping Internal Gripping The air gripper should be operated
point L (mm) 120 80 160 200 20 40 60 Gripping point L (mm) 80 0 20 40 60 Gripping point L (mm) 80 100 120 MHW2-25D MHW2-40D 160 50 Pressure 0.7 MPa Pressure 0.7 MPa MHZ 140 0.6 0.6 40 120 Gripping force (N) Gripping force (N) 0.5 0.5 MHF 100 30 0.4 0.4 80 0.3 MHL 0.3 0.2 20 60 0.2 40 MHR 10 20 MHK 0 20 40 60 Gripping point L (mm) 100 80 80 100 120 140 160 0 20 40 60 Gripping point L (mm)
60 40 20 0 0 50 30 10 Gripping point L mm Gripping point L mm MHF2-16D MHF2-20D 100 0.5MPa 100 Pressure 0.2MPa Pressure 0.2MPa 80 0.5MPa 0.6MPa 80 0.6MPa Overhang Hmm Overhang Hmm 0.3MPa 0.7MPa 0.3MPa 60 0.7MPa 0.4MPa 60 0.4MPa 40 40 20 20 100 80 60 40 20 0 100 80 60 40 20 0 Gripping point L mm Gripping point L mm 12-3-6 7 Model Selection Series MHF2 Confirmation of External Force on Fingers
force N Gripping force N 0.5MPa 0.5MPa 80 120 0.4MPa 0.4MPa 60 90 0.3MPa 0.3MPa 40 0.2MPa 60 0.2MPa 20 30 100 0 80 60 40 20 0 80 60 40 20 100 Gripping point L mm Gripping point L mm 2 Series MHF2 Model Selection Effective gripping force: Series MHF2 Step 2 External gripping Internal gripping The air gripper should be operated so that the amount of overhang "H" will stay within the range
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Passage symbol 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz External pilot Nil VT N.C. (Normally closed) A N.O.