Connect the motor power supply input terminal (U, V, W) to the driver power terminal (U, V, W).
IDX-OM-W093-B / Series IDF60-20-A,C,L,R,T,V IDF60-30-A,C,L,R,T,V IDF70-20-A,C,L,R,T,V IDF70-30-A,C,L,R,T,V IDF80-20-A,C,L,R,T,V IDF80-30-A,C,L,R,T,V IDF90-20-A,C,L,R,T,V IDF90-30-A,C,L,R,T,V URLhttp://www.smcworld.com/ English instruction manual can be downloaded from our URLhttp://www.smcworld.com/ SMC *1) JIS B8370 *2) ISO4414 *1) ISO4414Pneumatic fluid power Recommendations for the application
Color Symbol Color B Black W White R Red BU Blue G Green 15-6-10 1 Flame Resistant (Equivalent to UL-94 Standard V-0) FR Double Layer Tubing Series TRB Model Suitable for air and water piping in environments where sparks from spot welders, etc., may be a problem. Double layer design using flame resistant resin (equivalent to UL-94 Standard V-0) for outer layer.
Apparent power (VA) Volt-ampere is the product of voltage (V) and current (A). Power dissipation (W): For AC , W = V/A cos. For DC, W = V/A. (Note) cos shows power factor. cos = 0.6 2. Surge voltage A high voltage which is momentarily generated in the shut-off unit by shutting off the power. 3.
(at 25C water) Temperature characteristics 5% F.S. (0 to 50C, based on 25C) Pulse output, N channel, open drain, output for monitor unit PF2D 300/301 (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V) Pulse output Output Voltage output Note 5) 1 to 5 V Accuracy: 2% F.S., Min. load impedance: 100 k (Output impedance: 1 k) Analog specifications Current output Note
Handle: Flame resistant PBT (Equivalent to UL-94,V-0) Handle: Flame resistant PBT (Equivalent to UL-94,V-0) Material: Resin (Handle, bonnet) Material: Resin (Handle, bonnet) Bonnet: Flame resistant PBT (Equivalent to UL-94,V-0) Bonnet: Flame resistant PBT (Equivalent to UL-94,V-0) 76 g 76 g Body: Aluminum Body: Aluminum VHS20 (Aluminum body is standard): 190 g VHS20 (Aluminum body is standard
Grommet (G) Rated voltage DIN terminal (D) Part no. symbol Standard: Y, V, W Continuous duty type (E) Standard: Y, V, W Continuous duty type (E) W/o indicator light With indicator light W/o indicator light With indicator light W/o indicator light With indicator light No.1 No.1 Varistor Varistor S Diode Diode Coil Coil Coil Coil No.2 No.2 (G, GS) (D, DS) AC Vacuum Spec.
Nil F N T Rc G NPT NPTF Nil Non-locking type M Locking type (Tool required) Valve option Surge voltage suppressor Nil V Standard For vacuum Nil None CE-compliant CE-compliant With surge voltage suppressor Port size CE-compliant Nil Q 02 1 4 AC: Can be attached to Grommet, Conduit, Conduit terminal.
1000 V = D2 x L x (L) For the conductance, the equivalent conductance can be found in 8.
1000 V = D2 x L x (L) For the conductance, the equivalent conductance can be found in 8.
Refer to the AC adapter image below under Accessories. *2 The AC cord has a rated voltage of 125 V.
Grommet Yes 3-wire (NPN) 3-wire (PNP) 24 V Diagnostic indication (2-color indicator) 5 V, 12 V IC circuit 2-wire 12 V Water resistant (2-color indicator) 3-wire (NPN equivalent) Z76 5 V IC circuit Yes Grommet 12 V 100 V Z73 Relay, PLC 24 V 2-wire None IC circuit 100 V or less Z80 Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee
Designation Description Fieldbus interface connector (BUS IN) EtherNet/IPTM connection PORT 1 (M12 4-pin socket, D-coded) 4 2 SI24 V +24 V for SI unit operation 2 1 SV24 V +24 V for solenoid valve 2 Power supply connector Power supply with load voltage for valves and operating voltage for SI unit (M12 4-pin plug, A-coded) 3 1 3 SI0 V 0 V for SI unit operation MS NS L/A1 L/A2 PWR(V) 4 Ground
Designation Description 1 FG Function earth 2 0 V 0 V for solenoid valve 3 24 V +24 V for solenoid valve 4 SI0 V for SI unit operation 5 SI+ +24 V for SI unit operation The power supply connector included as an accessory can be used to supply the power. Applicable wire for the power supply connector is AWG24 to AWG16 (0.2 to 1.5 mm2).
Designation Description 2 Fieldbus interface connector (BUS IN) EtherCAT connection (M12 4-pole socket, D-coded) 4 5 2 *1: Blinking pattern SV24 V +24 V for solenoid valve 1 Power supply connector Power supply with load voltage for valves and operating voltage for SI unit (M12 5-pole plug, A-coded) 3 2 SV0 V 0 V for solenoid valve 200 ms 200 ms 1 SI24 V +24 V for SI unit operation 3 4 Ground
Mounting hole Mounting hole for connection to the valve manifold 7 4 5 2 SV0 V 0 V for solenoid valve 2 OFF SI unit operating voltage is not supplied. Accessories 3 SI24 V +24 V for SI unit operation Green ON Operating normally. ST Warning: WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.
.() AC1000 V1 50M (DC500 V ) CEULCSARoHS M50.8(11.5 Nm) PPSSiAuSUS316C3604() 30 g()10 g() 1 20 3VINOUT 5V OUTIN 1 V 3F.S.4 V(15 V) 40 kPa 5 2 0.15 mm 0.58 mm 0.88 mm 2.6 -19No.
When using a power supply in the overvoltage category 3, take measures such as mounting an isolation transformer between the product and the power supply or keep the transient overvoltage of the power supply to 2500 V or less by using a varistor, etc.
M V 1 1 [ ] 2 WH 18AWG BK 18AWG BK 9 9 2 V G 3 U U [ ] 1 RD 18AWG BK 5 5 1 U (CN3) PM PUMP 7 7 Option T1 6 6 4 4 3 3 2 2 1 1 PM PUMP 2/2 PM PUMP (CN1) 16AWG G/Y G4 [ ] V G PM 16AWG G/Y G4 [ ] G U DC Power Supply Standard BL DCPS [ ] 18AWG G/Y G2 5 5 Condenser 18AWG BK 1 1 3 3 3 3 18AWG BK 3 3 1 1 1 1 C3 (CN51) (CN1) (CN6) Compressor CM CM AC Power Board 3 1 PCB1 3 3 [ ] TH 14AWG BK 14AWG