Piping: 20 (Body Ported), Stations: 3 Stations, A, B Port: 00N (NPT), Bracket: F (Bracket)
Valve; Stop Valve: None), Return Port Size: 06 (3/4), Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 04 (1/2), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: J (Instantaneous Flow: L/min, Accumulated Flow: L, Temperature
AS420 Thread type AS500 AS600 AS800 Nil Rc NPT G N F 1 4 1 2 AS900 Needle Valve/Flow Rate Characteristics Note) The flow rate characteristics are representative values.
Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) @7 E F G H J K Rod seal Wiper ring Piston seal Valve seal NBR Tube gasket Retaining plate gasket As for the center trunnion type, it is very difficult to adjust the position of the trunnion bracket and the center of the axis. Therefore repair at SMC is recommended.
flow rate = Required air flow rate / (PCF x TCF x DCF) Dewpoint (F) -40 -100 Dewpoint correction factor (DCF) 1 0.7 15 Please contact SMC for more detailed information.
IS400-1 (1S-1) IS400-2 (1S-2) Model Port size B J A C D E F G H I , 1 4 1 2 1 1 AL800-12 to 14-1 AL900-20-1 431 (481) 437 (487) 3 x M5 x 0.8 x depth 6 3 x M5 x 0.8 x depth 6 230 230 ( ): With float switch 117 117 60 60 100 100 2 59 63 166 162 73 73 1046
Thread type AR8 5 AR6 5 Nil N F Rc NPT G Symbol 2 1 AR4 5BG AR6 5BG 678 Pilot Operated Regulator AR425 to 935 Series Flow Rate Characteristics (Representative values) Pressure Characteristics (Representative values) Inlet pressure: 0.7 MPa Conditions: Inlet pressure 0.7 MPa Outlet pressure 0.2 MPa Flow rate: 20 L/min (ANR) AR425/435 ARJ Outlet pressure (MPa) Outlet pressure (MPa) Outlet pressure
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 04 (1/2), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C),
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 03 (3/8), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C)
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal,
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 10 (1), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature
Series MHR3 11223 Finger Rotary Actuated Air Gripper Size: 10, 15 Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors Directional Control Valves Air Grippers Modular F. R.
(mm) ND NN Bore 10 16 A B C D F GA GB H MM NA NB S Z 0 0.022 0 0.022 15 12 14 4 8 8 5 28 M4 X 0.7 12.5 9.5 M8 X 1.0 46 74 75 8 15 18 20 5 8 8 5 28 M5 X 0.8 12.5 9.5 M10 X 1.0 47 10 Refer to p.1.3-8 to 1.3-10 for dimensions of each mounting bracket.
Description ARJM104, 6, 10 Manifold base How to Order ARJ1020F-M5-06 ARJ1020F-M5-04 M5 ARJ 20 10 F 04 1 Option Miniature regulator 1 Set at 0.2MPa Port size Only the adjusting spring is different from standard.
Rated Flow Range: 202 (20 to 2000 L/min), Thread Type: F (G), Port Size: 06 (3/4), Output Specifications: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Option 1: N (w/o Lead Wire and M8 Connector)